PV15BW MARATHON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

www.marathonsp.com PV15BW Photovoltaic Fuse Holder

30 Amps 1500 Volts DC

  • 10 - 14 AWG solid
  • 6 - 14 AWG stranded
  • Copper wire only Electrical Ratings
  • 30A, 1500V DC
  • SC withstand 50kA
  • CU9AL - 90°C connector terminal rating
  • Factory & field wiring
  • Touch Protection: IP-20 (IEC 60529) Agency Compliance
  • UL recognized fuse holder, evaluated to UL 4248-18, file no. IZMR2.E364954
  • CSA - class 3211 37. file no. LR21455 Material Information
  • Insulator base:
  • Thermoplastic
  • Flammability rating of insulator base UL94V0
  • Insulator base temperature rating: -40°C to 140°C (UL RTI)
  • Bus bar clamp - steel, zinc plated
  • Fuseclip - copper, tin plated
  • Spring - steel, zinc plated
  • Terminal screws - steel, zinc plated
  • RoHS compliant

www.marathonsp.com PDS 0489 REV-F 04/01/16 Termination Specifications Bus Bar Terminal Thickness Width Torque N-m (lbf-in) Wire Size (CU Stranded) Torque N-m (lbf-in) Wires / Terminal Wire Class (UL) 1 #6 - 14 2.0 N·m (17.7 lbf·in) 1 B, C #10 - 14 2.0 N·m (17.7 lbf·in) 2 B, C

  • Solid copper wire range: #10-14 AWG
  • Wire strip length: 0.50” (13 mm) Installation & Accessories
  • Mounting:
  • 7.5 X 35 mm DIN rail mountable
  • Safety Guidelines:
  • Do not open under load Catalog # Description PV15BW Fuse holder - midget (10 x 85mm) PV fuses EFH-MCCK C Ganging clips - used to group multiple fuse holders together as an assembly

1 MS PV15 01A White vinyl marking strip with printing (1-24)

1 MS PV15 01X White vinyl marking strip with no printing

ECPVFH End cap - covers the end opening(s) of the bus bar terminal MN35-2 Din rail - 35 x 7.5 x 200mm long, slotted MSK35 End bracket - for anchoring in place on din rail

  • Utilize typical copper bus bar ampacity tables

www.marathonsp.com PDS 0489 REV-F 04/01/16 Acceptable Fuses Manufacturer Part Number Reference Ratings: Amps Volts DC Interrupt Littelfuse SPXV006 6 1500 30kA Littelfuse SPXV008 8 1500 30kA Littelfuse SPXV010 10 1500 30kA Littelfuse SPXV012 12 1500 30kA Littelfuse SPXV015 15 1500 30kA Littelfuse SPXV020 20 1500 30kA Littelfuse SPXV025 25 1500 30kA Littelfuse SPXV030 30 1500 30kA Mersen HP15M6 6 1500 50kA Mersen HP15M7 7 1500 50kA Mersen HP15M8 8 1500 50kA Mersen HP15M10 10 1500 50kA Mersen HP15M12 12 1500 50kA Mersen HP15M15 15 1500 50kA Mersen HP15M20 20 1500 50kA Mersen HP15M25 25 1500 50kA Mersen HP15M30 30 1500 50kA Bussmann PV-2.25A14LF10F 2.25 1500 10kA Bussmann PV-2.5A14LF10F 2.5 1500 10kA Bussmann PV-3A14LF10F 3 1500 10kA Bussmann PV-3.5A14LF10F 3.5 1500 10kA Bussmann PV-4A14LF10F 4 1500 10kA Bussmann PV-15A14LF10F 15 1500 10kA Bussmann PV-20A14LF10F 20 1500 10kA Bussmann PV-25A14LF10F 25 1500 10kA Bussmann PV-32A14LF10F 32 1500 10kA ETI 2625201 4 1500 10kA ETI 2625239 5 1500 10kA ETI 2625202 6 1500 10kA ETI 2625203 8 1500 10kA ETI 2625204 10 1500 10kA ETI 2625205 12 1500 10kA ETI 2625240 15 1500 10kA ETI 2625206 16 1500 10kA ETI 2625207 20 1500 10kA ETI 2625208 25 1500 10kA

www.marathonsp.com PDS 0489 REV-F 04/01/16 Conditions of Acceptibility

  • Electrical spacings must be maintained according to the requirements of the equipment in which the product is installed.
  • End use temperature tests must be performed
  • The number of fuse holders attached to bus bar and the mounting methods will be judged in end use Drawing