SPM RADIOMETRIX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Radiometrix Ltd, SPM Eval-Kit page 1 Range of Features Direct interface to RS232 serial port Onboard regulator can provide 5V, 1A supply to power-up DTE (e.g. barcode scanner) Visual indications of operation through LEDs Access to internal diagnostic/Test modes using HyperTerminal Access to each data/control pins for external interface or testing Set-up and configuration using HyperTerminal Built-in command line configuration. PP3 9V battery powered. DC jack and terminal block provided for external supply Kit Contents The SPM Evaluation Kit comes with the following contentes:

2 SPM Evaluation Board 1

2 SPM/RPM modules (ordered separately)

2 9V battery (PP3) 2 1/4 wavelength whip antenna

4 Jumpers

1 SPM data sheet

1 SPM Eval-Kit data sheet

The following status LEDs will be activated depending on the SPM operation mode. LED Indication TX (Red) Transmitter enabled; RX (Green) Receiver enabled; blinks in Auto standby mode SIGNAL (bright Red) Preamble detected OK (bright Yellow) Valid packet received / Test passed Power (Green) Power Supply on Notes: 1. The standard SPM evaluation kit comes with 2 Evaluation Board. In order to test the point to multipoint and broadcast modes of the SPM, at least 3 Evaluation Board would be required. 2. BNC connector can be replaced with SMB connector or terminal block to use different antenna connection SpacePort Modem Evaluation KitSpacePort Modem Evaluation KitSpacePort Modem Evaluation KitSpacePort Modem Evaluation Kit Supports Point to Multi Point and Broadcast Mode Test The SpacePort Modem Evaluation Kit enables SPM / RPM to be transformed into a complete Radio Modem with DCE type RS232 interface. Radiometrix Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England

01 November 2004 SPM Eval-Kit

Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233 Figure 1: SpacePort Modem Evaluation Kit

Radiometrix Ltd, SPM Eval-Kit page 2 Additional requirements 1. DB9M – DB9F straight through serial cable 2. External power supply or DC power adaptor (optional) 3. PC/PDA with terminal program (e.g. Hilgraeve HyperTerminal) On-board regulator (LM340TS) can supply up to 1A current at 5V. The 5V supply line is connected to the pin 9 (Ring Indicator) of DB9F connector which enables any external host to be powered from pin 9 (+5V DC) and pin 5 (GND). Certain CCD barcode scanner can make use of this feature, eliminating the need for additional external power adaptor. Serial Pin outs – RS232 (EIA/TIA-574) and RS232D (EIA/TIA-561) DB9 DB25 Pin Function SPM Eval Kit (DCE) DTE 1 8 Data Carrier Detect Output Input 2 3 Receive Data Output Input 3 2 Transmit Data Input Output 4 20 Data Terminal Ready Input Output 5 7 Signal Ground - 6 6 Data Set Ready Outut Input 7 4 Request To Sent Input Output 8 5 Clear To Sent Output Input Receive data (RXD) Data Set Ready ( )DSR Data Carrier Detect ( )DCD Request To Send ( )RTS Transmit data (TXD) Clear to sent ( )CTS Data Terminal Ready ( )DTR Signal ground Vcc (5V) Figure 2: DB9 Serial Port pin label 9 22 Ring Indicator +5V DC output Input In certain applications a DB9M to RJ45 adaptor cable will be required to interface SPM to Host. e.g. barcode scanners. 1 1 8 8 Figure 3: RJ45 Male and Female connectors Pin No. Name Notes/Description

1 DSR/RI Data Set Ready/Ring Indicator

2 DCD Data Carrier Detect

3 DTR Data Terminal Ready

4 SGND Signal Ground

5 RD Receive Data

6 TD Transmit Data

7 CTS Clear To Send

8 RTS Request To Send

Interfacing SPM Evaluation Kit to Data Terminal Equipment (DTE) 1 1 3 3 4 4 5 5 6 6 7 7 9 9 DB9MDB9F SPM Eval Kit DTE Figure 4: DB9M-DB9F straight through modem cable DB25M 1 8 42 0 5 7 6 6 9 22 DB9F DTE Figure 5: DB9M-DB25F straight through modem cable The SPM Eval board interface is a 9 way female D type connector. The CTS, DSR and DCD are wired together eliminating the need for special RS232 cables in certain DTE interface configurations. When using SPM Eval Kit with DTE (e.g. printer and printer driver) which uses DTR/DSR flow control instead of RTS/CTS flow control, the shut down mode should be disabled in configuration by turning SHDN to OFF.

Radiometrix Ltd, SPM Eval-Kit page 4 SPM has a 2mm pitch pin-out for embedded system applications where PCB space is very limited. However, for the convenience of evaluating the module, separate rows of 0.1” pitch pin headers are provided on both sides of the SPM sockets. Oscilloscope probes can be easily connected on these to monitor data transmission on each stage from serial RS232 type data entering SPM, FRPC transmitting packetised data, SPM on receiving end sending serial data to attached Host and sending back Packet Acknowledgements. Oscilloscope screen capture below were taken during a large file transfer at 115,200bps using HyperTerminal with ZMODEM setting. They were captured on Laptop from Tektronix TDS2024 Digital Storage Oscilloscope fitted with TDS2CM Communications Extension Module. The wireless RS232 link was established using SPM Evaluation Kit with SPM2-433-28. Figure 9: Serial RS232 data transmission and reception with hardware flow control TXD-RS232 is the inverted RS232 data at TTL level entering the SPM module at 115,200bps. RPM sends the collected data bytes with necessary site, unit and other control information bytes to FRPC. CTS flow control is set high when the SPM buffer reaches about 66% full, to prevent attached PC from sending further data bytes. FRPC packetises all the bytes from RPM with preamble, synch byte, check sum and encodes each 8-bit byte into a 12-bit code for reliable transmission over the radio. TXD/AF trace is the packetised data transmission from FRPC to TXD pin of radio transceiver within the SPM module. RXD-RS232 is the received inverted RS232 data at TTL level sent by SPM to attached host PC. It can be seen from the trace that the RS232 data stream coming into SPM is broken into two parts and transmitted as two packets. SPM will not transmit the next packet until an acknowledgement for the previously transmitted packet is received if the ACKMODE is turned ON as shown in the following oscilloscope screen capture.

231 Kenton Lane

Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000 R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/licensing_numbering/radiocomms/licensing/licensing_policy_manual/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)845 456 3000 or 020 7981 3040 Fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk European Radiocommunications Office (ERO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk