RX2M-458-5 RADIOMETRIX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 11

Technical content

Features

! 433MHz version conforms to EN 300 220-3 and EN 301 489-3 and 458MHz version to MPT 1329 (UK specs) ! Any custom band between 420MHz and 480MHz with 5MHz (AR0) frequency range ! High performance double superhet, 128 channel PLL synthesizer with TCXO ! Data rates up to 5 kbps for standard module ! Usable range over 1km ! Fully screened. Low profile ! Feature-rich interface (RSSI, automatic noise squelch, analogue and digital baseband) ! Incorporate a 1200baud dumb modem ! Re-programmable via RS232 interface ! Low power requirements

Applications

! Handheld terminals ! EPOS equipment, barcode scanners ! Data loggers ! Industrial telemetry and telecommand ! In-building environmental monitoring and control ! High-end security and fire alarms ! Vehicle data up/download Technical Summary ! Size: 59 x 38 x 7mm ! Operating frequency: 458.5-459.1MHz or 433.05-434.79MHz ! 23 channels in 458MHz band (128 channels max.) ! Transmit power: +20dBm (100mW) nominal ! Supply range: 4.5V - 16V ! Current consumption: 100mA transmit, 13mA receive ! Data bit rate: 5kbps max. (standard module) ! Receiver sensitivity: -118dBm (for 12 dB SINAD) UHF Narrow Band FM multi channel radio modulesUHF Narrow Band FM multi channel radio modulesUHF Narrow Band FM multi channel radio modulesUHF Narrow Band FM multi channel radio modules The TX2M transmitter and RX2M receive r modules offer a low power, reliable data link in an industry-standard pin out an d footprint. This makes the TX2M/RX2M pai r ideally suited to those low powe r applications where existing wideban d modules have insufficient range, or where multi-channel operation is needed. Two versions are available, covering the 458.5 - 459.1MHz UK band (at 100mW) and the European 433.05-434.79MHz band. Radiometrix Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England Issue 3, 15 October 2007 TX2M/RX2M NEW Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233 RX2M-458-5T X 2 I-458-5

Radiometrix Ltd TX2M/RX2M Data Sheet page 2 Figure 1: TX2M block diagram

Radiometrix Ltd TX2M/RX2M Data Sheet page 3 Figure 2: RX2M block diagram

Radiometrix Ltd TX2M/RX2M Data Sheet page 4 Pin: C Name Function 1 0V Ground 2 TXE Transmitter enable. Low = ON, open = off. 4k7 internal pullup to Vcc 3 TXD DC coupled input for 3-12V CMOS logic. Leave open if unused 4 AF in AC coupled Analogue Input. Limit to 1Vpk-pk ±10% to keep distortion <1.5% and peak FM deviation >2.5kHz 5 +4.4Vout DC supply. 75mA maximum drain. Only present when TXE is low

6 PGM Serial programming/configuration input at RS232 level

8 P1 (MOD TXD)

9 P2 (MOD NC)

10 P3 (MOD TXH)

Parallel frequency select inputs. Inverted logic, 10k pullups to 4V Pin C Name Function 1 RSSI DC level between 0.5V and 2.5V. 60dB dynamic range 2 SQF Noise operated carrier detect. Open collector. ON/low = no signal 3 AF out 200mV pk-pk audio. DC coupled, approx 1V bias. Muted by squelch 4 RXD Open collector output of data slicer. Need external pull-up 5 +4.4V out DC supply. 75mA maximum drain. Present if unit is powered. 6 0V Ground

7 PGM Serial programming/configuration input at RS232 level

8 P1 (MOD NC)

9 P2 (MOD RXD)

10 P3 (MOD CDE)

Parallel frequency select inputs. Inverted logic, 10k pullups to 4V NOTES: 1. Internal AF Input gain is factory set for 1V pk-pk to produce 3kHz peak deviation and minimum distortion. Analogue gain may be set for an input level of 50mV – 2V pk-pk. This cannot be done without appropriate test equipment. Contact factory for details 2. Carrier detect on RX2M mutes the AF and DATA outputs when RF input signal is <-123dBm. This can be factory disabled if required. 3. There are no pullups on the open collector outputs. External pull-up resistor should be used. 4. With 1200baud modem mode enabled, parallel selection of channel is unavailable as the P1-P3 lines are used for input/output operations. Figure 3: TX2M Footprint (Top) view Figure 4: RX2M Footprint (Top) view Pin: A Name Function 1 +Vin +4.5-16V

2 Gnd Ground

Pin: B Name Function

1 Gnd RF ground

2 RF out To the antenna

3 Gnd RF ground

1 +Vin +4.5-16V

Radiometrix Ltd TX2M/RX2M Data Sheet page 5 TX2M and RX2M serial interface commands 2400 baud at RS232 level. 8 bit data, no parity, 1 start bit, 1 or 2 stop bits, No flow control. Transmit (pin 3 on DB9) and Signal Ground (pin 5 on DB9) should be connected to PGM and 0V pin. Command Format

Description

SINGLE nnnnn Set value of N for single channel operation GOCHAN xx Serial select of channel xx (0 to 127) LOADMX xx Set highest permitted (serial selected) channel xx (others default to ch0) LOADaa nnnnn Set value of N for channel aa (channels 0 to 15) LOADTB nnnnn Set value of N for channel 16 (channels 17 to 127 then in sequence) RVALUE rrrr Enter value for R register SETPAR Channel selected by 3 bit parallel input (0 to 7). Disable modem SETSER Channel selected by most recent GOCHAN operation SETMOD Enable internal modem. Frequency selected by most recent GOCHAN or SINGLE GOTEST 250Hz test tone modulated transmission <CR> Process entry (Carriage Return = 0D hex ) / Clear all buffers xx = channel number from 00 to 127 aa = two digit channel number from 00 to 15 nnnnn = synthesizer N register value, (up to 65535) rrrr = synthesizer R register value, (up to 16383) 1732225 050.433 === kHz MHz f fN cingChannelspa RF TX kHz MHz f fR cingchannelspa TCXO 13== , So R=520 1646625 MHz f MHzfN cingChannelspa RF RX Channel Number 433MHz band N value for TX N value for RX 458MHz band N value for TX N value for RX 0 433.050 /LOAD00 17322 /LOAD00 16466 458.525 /LOAD00 18341 /LOAD00 17485 1 433.075 /LOAD01 17323 /LOAD01 16467 458.550 /LOAD01 18342 /LOAD01 17486 2 433.100 /LOAD02 17324 /LOAD02 16468 458.575 /LOAD02 18343 /LOAD02 17487 3 433.125 /LOAD03 17325 /LOAD03 16469 458.600 /LOAD03 18344 /LOAD03 17488 4 433.150 /LOAD04 17326 /LOAD04 16470 458.625 /LOAD04 18345 /LOAD04 17489 5 433.175 /LOAD05 17327 /LOAD05 16471 458.650 /LOAD05 18346 /LOAD05 17490 6 433.200 /LOAD06 17328 /LOAD06 16472 458.675 /LOAD06 18347 /LOAD06 17491 7 433.225 /LOAD07 17329 /LOAD07 16473 458.700 /LOAD07 18348 /LOAD07 17492 8 433.250 /LOAD08 17330 /LOAD08 16474 458.725 /LOAD08 18349 /LOAD08 17493 9 433.275 /LOAD09 17331 /LOAD09 16475 458.750 /LOAD09 18350 /LOAD09 17494 10 433.300 /LOAD10 17332 /LOAD10 16476 458.775 /LOAD10 18351 /LOAD10 17495 11 433.325 /LOAD11 17333 /LOAD11 16477 458.800 /LOAD11 18352 /LOAD11 17496 12 433.350 /LOAD12 17334 /LOAD12 16478 458.825 /LOAD12 18353 /LOAD12 17497 13 433.375 /LOAD13 17335 /LOAD13 16479 458.850 /LOAD13 18354 /LOAD13 17498 14 433.400 /LOAD14 17336 /LOAD14 16480 458.875 /LOAD14 18355 /LOAD14 17499 15 433.425 /LOAD15 17337 /LOAD15 16481 458.900 /LOAD15 18356 /LOAD15 17500 16 433.450 /LOADTB 17338 /LOADTB 16482 458.925 /LOADTB 18357 /LOADTB 17501 F max 434.775 /LOADMX 69 /LOADMX 69 459.100 /LOADMX 23 /LOADMX 23 Please observe the following ERC/REC 70-03 (April 2004) Annex 1 recommendation when using the Non-specific Short Range Device (SRD) band for Telemetry, Telecommand, Alarms, Data in general and other similar applications. Frequency Band ERP Duty Cycle Channel spacing Notes E (433.050 - 434.790MHz) 10mW <10% No spacing E1 (433.050 - 434.790MHz) 1mW <100% No spacing E2 (434.040 - 434.790MHz) 10mW <100% <25kHz Audio and voice signals should be avoided in the band 433.050MHz - 434.790MHz Power density limited to -13dBm/10 kHz for wideband channels with a bandwidth greater than 250 kHz

Radiometrix Ltd TX2M/RX2M Data Sheet page 7 Pin description of TX2M/RX2M with Modem mode selected The 'modem' mentioned is a 1200 baud RS232 semi-intelligent unit (Transmitter is enabled when valid serial data is present, so no separate Transmit Enable control is needed. Coding in the data stream also permits the receiver to ignore noise and only output valid serial data. Pin Description - TX2M Pin Name Function 1 0V Ground

2 TXE Must be tied to 0V

3 N/C

4 N/C

5 +4.4Vout DC supply. 75mA maximum drain. Only present when TXE is low

8 MOD TXD (P1) Serial data input at RS232 level

9 MOD N/C (P2)

10 MOD TXH (P3) Active Low Transmit Hold for continuous transmission (useful for test)

1 RSSI DC level between 0.5V and 2.5V. 60dB dynamic range (only valid during databursts)

2 N/C

3 N/C (modem tones or noise present)

4 N/C (modem tones or noise present)

5 +4.4V out DC supply. 75mA maximum drain. Present if unit is powered 6 0V Ground

8 MOD N/C (P1)

9 MOD RXD (P2) Modem Received Data at TTL level (requires RS232 driver)

10 MOD CDE (P3) Pull low to enable Carrier Detect on modem operation (not recommended)

Both the TX2M and the RX2M should be configured to required operating frequency using GOCHAN command before starting to use the internal 1200 baud modem, because the P1-P3 pins will be used as Modem Data pins and the modem will operate on the last serially selected channel after SETMOD command is used to enable the Modem. NC (C2) +4.4V out (C5) GND (C6) (C7) MOD RXD (C9) PGM RX2M 4.5 - 15V Antenna 0V (C1) PGM (C6) (C7) TXE (C2) GND TX2M 3TXD SGD PC serial port 4.5 - 15V Antenna

3 TXD

100kΩ 100kΩ NPN uC UART µC UART 4.4V 0ut (C5) MOD TXD (C8) Figure 5: TX2M and RX2M interfaced to PC serial port in modem mode Note: Baud rate used for Modem is half that of used for serial configuration. Attached RS232 devices should be set with the following: 1200bps, 8 Data bits, No Parity, 1/2 stop bits, no flow control For TX2M, TXD (Pin 3) of a Serial Port can be switched from PGM (Pin C6) to MOD TXD (Pin C8) with no RS232 driver in between. However, in RX2M, MOD RXD (Pin C9) requires an RS232 line driver before it can be connected to RXD (pin 2) of a serial port. Some of the RS232 line drivers can be powered from the regulated +4.4V out (Pin C5).

Radiometrix Ltd TX2M/RX2M Data Sheet page 8 Condensed specifications Frequency 458.5-459.1MHz or 433-434MHz (any 5MHz band from 420-480MHz) Frequency stability +/- 1.5kHz Channel spacing 25kHz (12.5kHz by special order) Number of channels 128 channels controlled via RS232 interface (8 parallel selected) Supply voltage 4.5-16V Current 100mA nominal transmit 13mA receive Operating temperature -10 to +60 C (Storage -30 to +70 C) Size 59 x 38 x 7 mm Spurious radiations Compliant with ETSI EN 300 220-3 and EN 301 489-3 Interface user 8pin 0.1" pitch molex Power 2pin 0.1" pitch molex RF 3pin 0.1" pitch molex Recommended PCB hole size 1.2mm (min.) Intended approval ETSI Radio standard EN 300 220-3 and EMC standard EN 301 489-3 Transmitter Output power +20dBm(100mW) ± 1dB (factory adjustable 1 - 100mW) TX on switching time 50 ms Modulation type FM, FSK (F1D, F3D) TX modulation bandwidth DC – 3kHz Adjacent channel TX power -37dBm Inputs analogue, data (CMOS/TTL compatible) Receiver Sensitivity -112dBm for 1 part per 1000 BER -118dBm for 12 dB SINAD image / spurious -70dB Blocking -85dB adjacent channel <-60dB (Tested per. ETSI EN 301 489-3 Outputs RSSI, carrier detect, audio, data Power on to valid audio 28ms (no noise mute) Power on to valid audio 45ms (with noise mute) Power on to stable data out 50ms for 50:50 mark / space (with or without mute) Notes: 1. The data slicer cannot be depended upon for data waveform frequencies below 250Hz 2. When RX is on and a transmitter keys up, again a 50ms period is required to stabilise data output mark/space. i.e. allow at least 50ms of preamble Typical current consumption of TX2M at various RF output power level is as follows: RF output (mW) Current (mA) 100 90 50 67 25 54 10 41 53 5 13 0 Note: These measurements taken at 433MHz (for 458MHz current consumption increases by about 5%). RF power output can only be factory set.

Radiometrix Ltd TX2M/RX2M Data Sheet page 9 Operating principle of internal modem This device is a simplex link handling a 1200 baud asynchronous datastream (1 start, 8data, 1stop). Buffering in the transmit end handles TX startup timing requirements, while the presence of sync codes in the transmitted bursts prevents the receiver from outputting garbage in the presence of noise. No error correction or retransmission of lost packets is supported. To operate with proper +/-12V RS232 levels an external buffer (such as a MAX232) will be needed Physically the modem code resides in the PIC microcontroller which controls the radio functions. The modem uses the internal hardware serial port of the processor. Operation: Serial interface Both transmit and receive modems implement a 32 byte software FIFO. At the transmit end this is used to allow for the TX2M transmitter start up time (about 32mS), while on receive it buffers arriving packets to the constant output data rate. All timing and data formatting tasks are handled by the software. The user need not worry about keying the transmitter before sending data: the link is entirely transparent. For transmission across the link data is formatted into packets, each comprising 3 bytes of data and a sync code. If less than 3 bytes are in the transmit end FIFO then a packet is still sent, but idle state replaces the unused bytes. When the transmit end FIFO is completely emptied, then the transmitter is keyed off . Operation: Radio interface Raw data is not fed to the radios. A coding operation in the transmit software, and decoding in the receiver, isolate the AC coupled, potentially noisy baseband radio environment from the datastream. The radio link is fed a continuous tone by the modem. As in biphase codes, information is coded by varying the duration consecutive half-cycles of this tone. In our case half cycles of 500 µs (a long, or L) and 250µs (a short, or S) are used. In idle (or 'preamble') state, a sequence of Ls is sent (resembling a 1kHz tone). A packet comprises the Synchronising (or address) part : LSSSSSSSSSSSSL followed by the Data part, made up of twelve Groups (of four half cycles duration). Each Group encodes 2 data bits, so one byte is encoded by 4 Groups. Although there are 16 possible states for a four half cycle group (from SSSS to LLLL), only four of the possible states are used for valid data: All other possible group combinations (except LLLL) are void, and result in the entire packet being but does not void the packet, as a packet containing less than 3 bytes still needs to be decoded. The advantage of using the above coding technique: 1.Ease of decoding: Unlike biphase, where a bit is coded as either a long half cycle or a short cycle, here all half cycles are detected separately. 2. Inherent error detection: Although only 14 sync/address 'bits' (halfcycles) are used, the following 48 'bits' (halfcycles) only code 24 real data bits, leading to enhanced noise/error discrimination (the equivalent of 5 more sync bits). 3. Comparable spectral efficiency: For a maximum transmitted baseband frequency of 2kHz, a 3 byte packet is sent in 22ms. An equivalent biphase coded packet (comprising 19 sync + 24 data + 3 null flags) at 2kbits/sec takes 23ms

Radiometrix Ltd TX2M/RX2M Data Sheet page 10 Transmitter variant RX2M is designed to be pin and polarity compatible with existing industry standard modules. AF and Data Output are inverted relative to original transmitted signal. The transmitter is available in two variants – TX2I and TX2M The non-inverting transmitter called TX2M frequency modulates the carrier frequency in the normal sense whereby higher modulating voltage increases the carrier frequency and lower modulating voltage decreases the carrier frequency which results in an inverted AF and Data output on the receiver. This will be the standard module and exact plug-in replacement for existing industry standard modules. TX2M RX2M 433.047MHz 433.05MHz 433.053MHz 0V 3V No modulation Vcc AF RXDData slicer The inverting transmitter called TX2I reverses the Frequency Modulating order whereby the higher modulating voltage decreases the carrier frequency and lower modulating voltage increases carrier frequency which results in non-inverting AF and Data output on the receiver. This variant can be used for applications where data inversion will be problematic. TX2I RX2M 433.047MHz 433.05MHz 433.053MHz 0V3V No modulation Vcc AF RXDData slicer

Ordering information

Part Number Description Frequency band Maximum data rate TX2M-433-5 TX2M (non-inverting) transmitter 433.05MHz-434.790MHz 5kbps TX2I-433-5 TX2I (inverting) transmitter 433.05MHz-434.790MHz 5kbps RX2M-433-5 RX2M receiver 433.05MHz-434.790MHz 5kbps TX2M-458-5 TX2M (non-inverting) transmitter 458.525MHz-459.100MHz 5kbps TX2I-458-5 TX2I (inverting) transmitter 458.525MHz-459.100MHz 5kbps RX2M-458-5 RX2M receiver 458.525MHz-459.100MHz 5kbps TX2M-458-10 TX2M (non-inverting) transmitter 458.525MHz-459.100MHz 10kbps TX2I-458-10 TX2I (inverting) transmitter 458.525MHz-459.100MHz 10kbps RX2M-458-10 RX2M receiver 458.525MHz-459.100MHz 10kbps Figure 8: Data polarity change from TX2I (inverting) transmitter to RX2M receiver Fi gure 7: Data polarity change from TX2M (non-inverting) transmitter to RX2M receiver

231 Kenton Lane

Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in wholeor in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000. R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/radiocomms/ifi/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)845 456 3000 or 020 7981 3040 Fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk European Radiocommunications Office (ERO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk