SPL375-100-C105M ROITHNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

www.roithner-laser.com 1 SPL375-100-C105M

  • UV Pigtailed Laser Diode
  • 375 nm, 100 mW
  • 105 µm MM Fiber
  • FC/PC Connector Maximum Rating Parameter Symbol Values Unit Min. Max. Reverse Voltage VR 2.0 V Operating Temperature TOPR + 15 + 30 °C Storage Temperature TSTG - 40 + 85 °C Soldering Temperature (max. 3s) TSOL + 260 °C Electro-Optical Characteristics (TCASE = 25°C) Parameter Symbol Values Unit Min. Typ. Max. Peak Wavelength λP 365 375 385 nm Output Power PO 100 mW Spectral Width (FWHM) 2.0 nm Operating Voltage VF 4.5 6.0 V Threshold Current Ith 200 300 mA Operating Current IO 300 400 mA Fiber Spec. Type Multi-Mode Core diameter 105 µm Connector FC/PC* Length 80 cm *SC / SMA905 available on request

Description

SPL375-100-C105M is an ultra-violet pigtailed laser diode, typically emitting at 375 nm with an output power of 100 mW. It comes in a coaxial package with heat sink, and 105 µm multi-mode fiber with FC/PC connector. Variants with different types of connectors are optionally available.

www.roithner-laser.com 2 Electrical Connection Pin Configuration* Bottom View Pin # Function Pin 1 LD anode Pin 2 LD cathode * subject to change Outline Dimension All dimensions in mm Precautions Safety Laser light emitted from any laser diode may be harmful to the human eye. Avoid looking directly into the laser diode’s aperture. The use of optical lenses will increase eye hazard ESD Caution Always do handle laser diodes with care to prevent electrostatic discharge. We advise to wearing wrist straps, and grounding all applicable work surfaces, when handling laser diodes Operating Considerations Usage of current regulated drive circuits is mandatory We advise to operate this laser diode with a current source and heat sink, and to never exceed the maximum specifications as outlined in this datasheet. © All Rights Reserved The above specifications are for reference purpose only and subjected to change without prior notice