LD1625-C120 ROITHNER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
- Lasing Mode Structure: single mode
- Peak Wavelength : typ. 1625 nm
- Optical Ouput Power: 120 mW, pulse mode
- Package: 5.6 mm, flat window Absolute Maximum Ratings (TC=25°C) Item Symbol Value Unit CW Output Power PO 120 mW LD Reverse Voltage Vr 2 V LD Forward Current Iop 1200 * mA Operating Case Temperature TC 0 … +60 °C Storage Temperature Tstg -40 … +85 °C * DC ≤ 1%, PW ≤ 10 µs Specifications (TC=25°C) Item Conditions Symbol Min. Typ. Max. Unit Optical Specifications CW Output Power Iop=500mA, PW=10µs, DC=1% PO 100 120 - mW Center Wavelength Iop=500mA, PW=10µs, DC=1% λC 1600 1625 1650 nm Spectral Width * Iop=500mA, PW=10µs, DC=1% Δλ - 4 7 nm Θ║ - 17 - deg. FWHM Beam Divergence CW, PO=40mW Θ┴ - 44 - deg. Electrical Specifications Threshold Current PW=10µs, DC=1% Ith - 45 - mA Slope Efficiency CW, PO=40mW η - 0.3 - W/A Operating Voltage CW, PO=40mW V op - 1.0 1.9 V * RMS, -20 dB The above specifications are for reference purpose only and subjected to change without prior notice.
13.09.2011 LD1625-C120 2 of 4
5.6 mm Package (Unit:mm) Bottom View PIN Funciton
1 Case, LD Anode
2 LD Cathode
13.09.2011 LD1625-C120 3 of 4
Typical Performance Curves Chip-level LI curve, 25°C fixture temperature CW mode (blue), pulsed (10 µs PW, 1% DC) mode (magenda) Chip-level far field curves, CW mode, Pop = 40 mW, 25°C fixture temperature prependicular (blue), parallel (red)
13.09.2011 LD1625-C120 4 of 4
Chip-level spectral measurement pulsed (10 µs PW, 1% DC) mode, 25°C fixture temperature Safety of Laser light
- Laser Light can damage the human eyes and skin. Do not expose the eye or skin directly to any laser light and/or through optical lens. When handling the LDs, wear appropriate safety glasses to prevent laser light, even any reflections from entering to the eye. Focused laser beam through optical instruments will increase the chance of eye hazard.
- The LD emitts invisible light Cautions 1. Operating methode
- This LD shall change its forward voltage requirement and optical ouput power according to temperature change. Also, the LD will require more operation current to maintain same ouput power as it degrades. [In order to maintain output power, use of APC (Automatic Power Control) is recommended. Which use monitor feedback to adjust the operation current.]
- Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current level specified her ein above as absolute maximum rating. Also, employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit. 2. Static Electricity
- Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist trap or anti-electrostatic glove when handeling the product. 3. Absolute Maximum Rating
- Active layer of LDs shall have high current density and generate high electric field during its operation. In order to prevent excessive dam age, the LD must be operated striclty below absolute maximum rating.