Bauart geprüft Typ e a p p r o v ed 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 28/02/2017 Model Mounting ( D = Din rail ) Output voltage Output power Input type Input type: 2= single phase high voltage (bi-phase) Output Performances
- Installation on DIN Rail 7.5 or 15mm
- Short circuit protection
- Input single phase 340 to 575VAC
- Passive PFC
- Power ready output on 24VDC
- LED indicator for DC power ON
- LED indicator for DC low
- Standard parallel function
- Very compact dimensions
- UL, cUL listed and TUV/CE approved Product De scrip tion This particular SPD is the most compact 100W power supply on the market. Relay output for “power ready” parallel function and PFC are included. Performances are unique with high efficiencies and the possibility of being used up to 70°C with a little derating. Furthermore it can be powered with 2 phases of a 3 phase grid system due to its high voltage input. Switching Power Supply Type SPD 100W Bi-Phase DIN rail mounting Output voltage accuracy -0 +1% max (factory adjusted) Line regulation ± 1% Load regulation Non parallel model ± 1% Parallel model ± 5% Temp. coefficient ± 0.03% / °C Ripple and noise 50mV Vi nom, Io nom, BW=20MHz Rated continuous Loading 8.4A @ 12VDC / 6.9A @14.5VDC 4.2A @ 24VDC / 3.5A @ 28.5VDC 2.1A @ 48VDC / 1.8A @ 56VDC Fall Time 150ms Transient recovery time V i nom, Io= 0.5 x Inom 2ms Turn On Time Vi nom, Io nom 1.0s Vi nom, Io nom with Capacitor load 1.5s Output Data Ordering Key SP D 24 100 2 Rise Time Vi nom, Io nom 150ms Vi nom, Io nom with Capacitor load 500ms Capacitor Load 12V, 24V versions 7000µF 48V version 3500µF Reverse Voltage Immunity 12V 18V 24V 35V 48V 63V Hold up Time Vi nom Io max 20ms Minimum load Vi nom 0% Parallel Operation 2 units max. 0.1 Io min~0.9 Io max Model Rated output Voltage (VDC) Output Power (W) Output Current (A) Voltage Trim Range
0.8 Io nom
DC ON LED (VDC) Threshold at startup DC LO LED (VDC) Threshold after startup Typical
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 28/02/2017 2 Rated input voltage 400/500VAC Voltage range AC in 340 - 575VAC DC in 480 - 820VDC Rated input current 0.48A / 0.75A Power dissipation 12V 15.0W 24V 13.0W 48V 10.5W Input Data Input Fuse 2A/600VAC internal1) Output Short Circuit current limit Rated Overload Protection 115 - 135% Over voltage protection (auto recovery) 12V model 14.5V to 17.4V 24V model 30.0V to 33.0V 48V model 60.0V to 66.0V Controls and Protections Ambient temperature -25°C to 71°C Derating (>61°C to +71°C) 2.5% / °C Ambient humidity 20 to 95%RH Storage -25°C to +85°C Pollution degree 2 Protection degree IP20 Cooling Free air convection Switching frequency 45kHz General Data (@ nominal line, full load, 25°C ) Insulation voltage Input / Output 3.000VAC / 4242VDC Input / FG 1500VAC / 2121VDC Insulation resistance 100MΩ min Shock resistance acc. to IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) Vibration resistance acc. to IEC 60068-2-6 (Mounting by rail: 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis) UL / cUL UL 508 Listed UL 60950-1 TUV EN 60950-1, CB scheme EN 61558-1, EN 61558-2-17 (acc.to EN 60204) Approvals and EMC 1) Fuse not replaceable by user Frequency range 47 - 63Hz Internal Voltage Surge Protection Varistor (acc. to IEC61000-4-5) Leakage Current Input / Output 0.25mA Input / FG 3.5mA Inrush current 10A P.F.C. 0.55 Input Voltage Surge Protection Varistor Power ready (only SPD241002) Threshold at start up Min. 17.6VDC - Max.19.4VDC (contact closed) Contact rating at 60VDC 0.3A Insulation 500VDC MTBF (Bellcore Issue 6@40°C), GB 12V model 622.000h 24V model 661.000h 48V model 672.000h Altitude during operation 3.000m Case material Plastic Dimensions L x W x D 90 x 54 x 114mm Weight 500g CE EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 Switching Power Supply Type SPD 100W Bi-phase DIN rail mounting
3 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 28/02/2017 Switching Power Supply Type SPD 100W Bi-phase DIN rail mounting Pin No. Designation Description
1 RDY NO relay contact for DC OK (only SPD241002)
2 RDY NO relay contact for DC OK (only SPD241002)
3 V+ Positive output terminal
4 V+ Positive output terminal
5 V- Negative output terminal
6 V- Negative output terminal
7 GND Ground terminal to minimise High frequency emissions
8 N or L2 Neutral or phase 2 (no polarity with DC input)
9 L1 Phase 1 (no polarity with DC input)
L1 DC ON DC output ready LED L2 DC LO DC low indicator LED POT1 Vout ADJ. Trimmer for fine output voltage adjustment SW1 S/P Single / Parallel select switch Pin Assignment and Front Controls Typ. Current Limited Curve Output Voltage ( % ) 100 110 120 130 140 150 160 170 Hiccup mode L1 Fuse1 Y P.F.C CircuitFilterN(L2) Filter X Bridge Recti/f_ier X Vo- Vo+ PWM Controller Switching Device Recti/f_ier Opto- Isolation Output Level Detection Vout ADJ. DCON (Green LED) RDY (Relay Contact) Opto- Isolation OverVoltage Detection DCLOW (Red LED) Current Detection Single/Parallel SelectReference& ErrorAmp. 1) only for SPD241002 Power Out (%)Power Out (%) Output Voltage (%) 100 Hiccup mode Output Voltage ( % ) 100 110 120 130 140 150 160 170 Hiccup mode L1 Fuse1 Y P.F.C CircuitFilterN(L2) Filter X Bridge Recti/f_ier X Vo- Vo+ PWM Controller Switching Device Recti/f_ier Opto- Isolation Output Level Detection Vout ADJ. DCON (Green LED) RDY (Relay Contact) Opto- Isolation OverVoltage Detection DCLOW (Red LED) Current Detection Single/Parallel SelectReference& ErrorAmp. 1) only for SPD241002 Power Out (%)Power Out (%) Output Voltage (%) 100 Hiccup mode Block Diagrams Output Voltage ( % ) 100 110 120 130 140 150 160 170 Hiccup mode L1 Fuse1 Y P.F.C CircuitFilterN(L2) Filter X Bridge Recti/f_ier X Vo- Vo+ PWM Controller Switching Device Recti/f_ier Opto- Isolation Output Level Detection Vout ADJ. DCON (Green LED) RDY (Relay Contact) Opto- Isolation OverVoltage Detection DCLOW (Red LED) Current Detection Single/Parallel SelectReference& ErrorAmp. 1) only for SPD241002 Power Out (%)Power Out (%) Output Voltage (%) 100 Hiccup mode SPD241002 / 400VAC SPD241002 / 500VAC
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 28/02/2017 4 Derating Diagram Mechanical Drawings mm (inches) Ventilation and cooling Normal convection All sides 25mm free space for cooling is recommended Screw terminals 10-24AWG flexible or solid cable 8mm stripping recommend Max. torque for screws terminals Input terminals 1.008Nm (9.0lb-in) Output terminals 0.616Nm (5.5lb-in) Plug-in connectors 10-24AWG flexible or solid cable 7mm stripping recommend Max. torque for plug-in terminals Input terminals 0.784Nm (7.0lb-in) Output terminals 0.784Nm (7.0lb-in) Recommended circuit breaker 3A / 5A / 6A B, D characteristics Installation Typ. Efficiency Curve Switching Power Supply Type SPD 100W Bi-phase DIN rail mounting