Radiometrix Ltd, SP2 data sheet page 1 SAW controlled FM transmitter and superhet receiver Reliable 50 meter in-building range, 200m open ground Built-in diagnostic / debug test modes Complies with ETSI EN 300 220-3 Complies with ETSI EN 301 489-3 Single 5V supply @ < 25mA 160kbps half duplex Free format packets of 1 - 60 bytes Packet framing and error checking are user transparent Collision avoidance (listen before transmit) Direct interface to 5V CMOS logic Power save mode I NTRODUCTION The SP2 is a self-contained plug-on radio port which requires only a simple antenna, 5V supply and a byte-wide I/O port on a host microcontroller (or bi-directional PC port). The module provides all the RF circuits and processor intensive low level packet formatting and packet recovery functions required to inter-connect an number of microcontrollers in a radio network. A data packet of 1 to 60 bytes downloaded by a Host microcontroller into the SP2's packet buffer is transmitted by the SP2’s transceiver and will "appear" in the receive buffer of all the SP2's within radio range. A data packet received by the SP2’s transceiver is decoded, stored in a packet buffer and the Host microcontroller signalled that a valid packet is waiting to be uploaded. HOST HOSTSP2 downloaddownload uploadupload transmit / receive The SP2-433-160 is a highly integrated intelligent transceiver module, which enable a radio network/link to be simply implemented between a number of digital devices. The module combines a UHF radio transceive r and a 160kbps Fast Radio Packet controller (FRPC). SP2-433-160 figure 1: SP2 + Host µµµµ-controller Radiometrix Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England Issue 2, 09 February 2007 SP2-433-160 UHF SpacePort TransceiverUHF SpacePort TransceiverUHF SpacePort TransceiverUHF SpacePort Transceiver NEW Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233

Radiometrix Ltd, SP2 data sheet page 2 PREAMBLE DETECTOR SERIAL RX FRAME SYNC. DETECT PREAMBLE DATA SLICER GENERATOR CRC GENERATOR/ CHECKER 12 8 TX RX CLOCK OSCILLATOR clkData STATE CONTROLLER PARAMETER / DATA STORE

63 BYTES E PROM

16.384MHz 22p 22p 10K 220nF1K TX Space Port Controller SIGNAL (10) SAW band pass filter Pre - am plifier

418 MHz

15.82 MHz

TXD/AF (7) TX/RX Supply Switch TX/RX switch VTX 10kΩ BiM2-433-160 UHF Module RF GND Antenna RF GND RX Select TX Select GND TXD/AF NC NC SIGNAL GND 39 mm 36.5mm 4 mm side view top view side view recommended PCB hole size: 0.9 mm TXA RESET RXR RXA Vcc GND 23 mm pin pitch: 2 mm 0889 ! figure 3: Pin out and physical dimension

Radiometrix Ltd, SP2 data sheet page 3 1. FUNCTIONAL DESCRIPTION On receipt of a packet downloaded by the Host, the FSP2 will append to the packet: Preamble, start byte and a error check code. The packet is then coded for security and mark:space balance and transmitted through the BiM2 Transceiver as a 160kbps synchronous stream. One of four methods of collision avoidance (listen before TX) may be user selected. When not in transmit mode, the SP2 continuously searches the radio noise for valid preamble. On detection of preamble, the SP2 synchronises to the in-coming data stream, decodes the data and validates the check sum. The Host is then signalled that a valid packet is waiting to be unloaded. The format of the packet is entirely of the users determination except the 1st byte (the Control Byte) which must specify the packet type (control or data) and the packet size. A valid received packet is presented back to the host in exactly the same form as it was given. To preserve versatility, the SP2 does not generate routing information (i.e. source/ destination addresses) nor does it handshake packets. These network specific functions should be performed by the host. Additional features of the SP2 include extensive diagnostic/debug functions for evaluation and debugging of the radio and host driver software, a built in self test function and a sleep mode / wake-up mechanism which may be programmed to reduce the average current to less than 100 µA. The operating parameters are fully programmable by the host and held in EEPROM, the host may also use the EEPROM as a general purpose non-volatile store for addresses , routing information etc. 1.1 O PERATING STATES The SP2 has four normal operating states:

  • I DLE / SLEEP
  • HOST TRANSFER
  • TRANSMIT
  • RECEIVE IDLE/SLEEP The IDLE state is the quiescent/rest state of the SP2. In IDLE the SP2 enables the receiver and continuously searches the radio noise for message preamble. If the power saving modes have been enabled the SP2 will pulse the receiver on, check for preamble and go back to S LEEP if nothing is found. The 'ON' time is 2.5ms, OFF time is programmable in the SP2’s EEPROM and can vary between 22ms and 181ms. The TX Request line from the Host is constantly monitored and will be acted upon if found active (low). A TX Request will immediately wake the SP2 up from S LEEP mode. HOST TRANSFERS If the host sets the TX Request line low a data transfer from the Host to the SP2 will be initiated. Similarly the SP2 will pull RX Request low when it requires to transfer data to the Host (this may polled or used to generate a Host interrupt). The transfer protocol is fully asynchronous, i.e. the host may service another interrupt and then continue with the SP2 transfer. It is desirable that all transfers are completed quickly since the radio transceiver is disabled until the Host <> SP2 transfer is completed. Typically a fast host can transfer a 60 byte packet to / from the SP2 in under 1ms.

Radiometrix Ltd, SP2 data sheet page 4 TRANSMIT On receipt of a data packet from the host, the SP2 will append to the packet - preamble, frame sync byte and an error check sum. The packet is then coded for mark:space balance and transmitted. A full 60 byte packet is transmitted in 6ms of TX air time (60 data bytes @ 160kbps + 1.75ms). Collision avoidance (Listen Before Transmit-LBT) functions can be enabled to prevent loss of packets. Data packets may be sent with either normal or extended preamble. Extended preamble is used if the remote SP2 is in power save mode. Extended preamble length can be changed in the EEPROM memory. R ECEIVE On detection of preamble from the radio receiver, the SP2 will phase lock, decode and error check the incoming synchronous data stream and if successful. The data is then placed in a buffer and the RX Request line is pulled low to signal to the host that a valid packet awaits to be uploaded to the Host. An in-coming data packet is presented back to the host in the same form as it was given.

Radiometrix Ltd, SP2 data sheet page 5

2 THE HOST INTERFACE

2.1 S IGNALS It is recommended that the SP2 be assigned to a byte wide bi-directional I/O port on the host processor. The port must be such that the 4 data lines can be direction controlled without affecting the 4 handshake line. pin pin pin I/O description name number function TXR 15 TX Request I/P Data transfer request from HOST to SP2 TXA 14 TX Accept O/P Data accept handshake back to HOST RXR 13 RX Request O/P Data transfer request from SP2 to HOST RXA 12 RX Accept I/P Data accept handshake back to SP2 D0 17 Data 0 (4) Bi-dir 4 bit bi-directional data bus. Tri-state D1 18 Data 1 (5) Bi-dir between packet transfers, Driven on D2 19 Data 2 (6) Bi-dir receipt for Accept signal until packet D3 20 Data 3 (7) Bi-dir transfer is complete. notes: 1. The 4 Handshake lines are active low 2. The 4 Data lines true data 3. Logic levels are 5V CMOS, see electrical specifications 4. Input pins have a weak pull-up internally R ESET The Reset signal, may either be driven by the host (recommended) or pulled up to Vcc via a suitable resistor (10kΩ). A reset aborts any transfers in progress and restarts the Packet Controller. H OST DRIVEN RESET Minimum low time: 1.0 µs, after reset is released (returned high). The host should allow a delay 1ms after reset for the SP2 to initialise itself During this delay the host must hold TXR high (unless D IAGNOSTIC MODES are required) and RXR signal should be ignored. Host Processor BiM2-433-160 Transceiver SP2-433-160SP2-433-160SP2-433-160SP2-433-160 RESETRESETRESETRESET D0D0D0D0 D1D1D1D1 D2D2D2D2 D3D3D3D3 figure 4: Host to SP2 connection

Radiometrix Ltd, SP2 data sheet page 6

2.2 HOST TO SP2 DATA TRANSFER

Data is transferred between the SP2 and the H OST 4 bits (nibbles) at a time using a fully asynchronous protocol. The nibbles are always sent in pairs to form a byte, the Least Significant Nibble (bits 0 to 3) is transferred first, followed by the Most Significant Nibble (bits 4 to 7). Two pairs of handshake lines, REQUEST & ACCEPT, control the flow of data in each direction:- TX Request & TX Accept: control the flow from the HOST to the SP2 (download) RX Request & RX Accept: control the flow from the SP2 to the HOST (upload) A packet transferred between host and SP2 consists of between 1 and 61 bytes, the first byte of the packet is always the control byte. There are two classes of H OST ↔ SP2 transfers: 1. Data Packets: To the transmitter or from the receiver 2. Memory Access: To or from the SP2's memory Byte Count (1-60)000 Packet To Transmit SP2 Byte Count (1-60)00 Received Packet SP2 067 6 bits control byte 1 data byte st 2 data byte nd 3 data byte rd figure 5: SP2 ↔↔↔↔ Host data transfer

Radiometrix Ltd, SP2 data sheet page 7

2.2.1 WRITE A BYTE TO SP2

The sequence for a byte transfer from the Host to the SP2 (i.e. TX download) is asynchronous and proceeds as follows: 1. HOST asserts TX Request line low to initiate transfer 2. Wait for SP2 to pull TX Accept low (i.e. request is accepted) 3. Set data lines to output and place LS nibble on the data lines 4. Negate TX Request (set to 1) to tell SP2 that data is present. 5. Wait for SP2 to negate TX Accept (i.e. data has been accepted) Repeat steps 1-5 with MS nibble. (TXR) (TXA) least significant nibble LS nibble MS nibble 1 byte DATA (4 LINES D0-D3) data present request accept data has been read data may change transfer request most significant nibble TX-REQUEST TX-ACCEPT Notes:

  • The data bus must not be set to output until step 3. i.e. after the SP2 has accepted the request. The bus may be left as an output until the entire packet has been transferred to the SP2, it should then be set back to input (default state).
  • The SP2's normal response time to the initial TX Request may be up to 1ms, thereafter, for the duration of the packet, the response will be fast.
  • The SP2 will ignore a TX Request from the Host while it is receiving a packet from the radio. If the incoming packet fails it's error check the SP2 will respond to the TX Request as normal, i.e. the TX Accept from the SP2 will be delayed until the incoming packet has finished. If a valid packet is received this must be uploaded to the Host before the SP2 can respond to the Host’s TX Request. Thus an RX Request will be signalled to the Host and not the expected TX Accept and the Host must upload the incoming packet before the TX packet can be downloaded. The TX Request should be left asserted (low) during the upload. The SP2 will respond as normal after the upload is completed.
  • For the above reason it is often easier to use RX Request to trigger a HOST interrupt and upload the SP2 to the HOST under interrupt control.
  • See Appendix B and C. for example SP2 driver subroutines. figure 6: TX download timing diagram

Radiometrix Ltd, SP2 data sheet page 8

2.2.2 READ A BYTE FROM THE SP2

The sequence for a byte transfer from the SP2 to the HOST (i.e. RX upload) is asynchronous and proceeds as follows :- 1. SP2 will assert RX Request line low to initiate transfer 2. Host pulls RX Accept low (i.e. request is accepted by the host) 3. SP2 will turn on it's bus drivers, place LS nibble onto data lines and negate RX Request (set to 1) 4. Host reads the data and negates RX Accept (i.e. data has been accepted) Repeat steps 1-4 with MS nibble. (RXR) (RXA) Least significant nibble LS nibble MS nibble 1 byte DATA (4 LINES D0-D3) data present request accept data has been read data may change transfer request most significant nibble RX-REQUEST RX-ACCEPT Notes:

  • The SP2 will turn off it's data bus drivers after the entire packet has been uploaded to the HOST.
  • See Appendix B and C. for example SP2 driver subroutines. 2.3 H OST <> SP2 PACKET FORMAT

2.3.1 THE CONTROL BYTE

The first byte of a SP2 <> HOST packet transfer is always the C ONTROL BYTE. This byte is used to control the transfer and contains information about the type of packet, number of bytes to be transferred, memory address, read/write bit etc. Bit 7 of the control byte is the Packet Type flag, PT, it determines the class of transfer and the interpretation of the other bits in the control byte. figure 7: RX upload timing diagram

Radiometrix Ltd, SP2 data sheet page 9

2.3.2 SENDING AND RECEIVING DATA PACKETS

Data packets are sent to / received from remote SP2’s. They begin with a control byte with bit 7 cleared and may be of variable length and contain up to 60 bytes of user determined data. BC5 - BC0 - 6 Bit Byte Count PT - Packet Type PT WU0 BC4 BC3 BC2 BC1 BC0 4 3 210

6 Bit byte count (includes itself), byte count must

be in the range 1 to 61 (01 to 3D HEX) 0 = Data Packet WU0 Function Normal preamble Power save wake-up WU0 - Preamble Control EEPROM Parameter location 01 determines timeH location 02 determines timeH BC5 The remainder of the bytes in the data packet are of the users determination. The packet would usually be made up of a number of fields consisting of some but not necessarily all of the following :- Source address / ID Destination address / ID System ID Packet count Encryption / Scrambler control Additional error check codes ( The SP2 performs it's own error checks) Routing information ( for repeaters) Link control codes (connect/disconnect/ACK/NAK etc.) Data field

2.3.3 SP2 M

The SP2’s EEPROM memory can be accessed by setting bit 7 in the control byte. Bit 6 (R/W flag) defines a memory read or write. The bits left define the address. Write to memoryRead from memory

10 Address (6 bit)

11 Address (6 bit)

0710 Address (6 bit)

figure 8: Control byte for data packet figure 9: SP2 memory access

Radiometrix Ltd, SP2 data sheet page 10 SP2 Memory READS: Host issues just the control byte, with bit 6 (W/R) cleared, bit 7 (PT) set and the memory address. The SP2 will respond with 2 bytes, the first is a control byte which is an echo of the control byte just issued by the host, this is useful if the host is using an interrupt handler. The 2nd byte is the memory contents. SP2 Memory WRITES: Host issues 2 bytes, the first is the control byte with bit 6 (W/R) set, bit 7 (PT) set and the memory address. The 2nd byte is the data to be written. The SP2 does not give a response to memory writes. A5-A 0 - 6 RPC Memory Address PT W/R 7 43 2 1 0 PT - Packet Type 1 = Memory Transfer Packet A4 A3 A2 A1 A0A5 R/W Function R/W - Memory Read / Write Write to RPC's memory Read from RPC's memory Notes Memory writes to locations 01 to 3F, write to the non-volatile EEPROM in the SP2. The EEPROM has a limit of 100,000 write cycles therefor it's use must be restricted to infrequently changed data. The SP2 only writes to the EEPROM when instructed to by the HOST. Each byte takes 10ms to write. To prevent accidental/spurious writes to EEPROM the host must set the WE bit in SWITCHES prior to EACH byte to be written. We recommend that the host performs a read/verify after each byte write to EEPROM. The above does not apply to any memory reads nor to writes to SWITCHES (address 00h). figure 10: Control byte for memory access

Radiometrix Ltd, SP2 data sheet page 11

3.0 SP2’S SWITCHES

S WITCHES is memory location 00h in RAM, it contains 8 flags which are used to determine the SP2's operation. On SP2 reset, power-up or watchdog Time-Out it is loaded from location 08h (in EEPROM). The default value is 00 hex - this is all functions deselected. PS1 & PS0 - Power Saving PS1 PS0 Function Continuous Power Save Sleep Off LBT DBT Function Immediate TX, no channel check Fixed delay TX, no channel check Immediate TX after channel clear Random delay TX after channel clear ST - Self Test Flag WE - EEPROM Byte Write Enable RTO - Radio Time Out No Time Out Time Out after > 2.9 S of plain preamble LBT & DBT - Collision Avoidance HTO - Host Time Out No Time Out Time Out if no reply from host after 2.9S PS1 PS0 RTO HTO WE ST LBT DBT 7654 3 21 0

3.1 PS0 & PS1 - P

The SP2 has 4 levels of power saving selected by PS0 & PS1 in SWITCHES. Power saving is achieved by shutting down the Transceiver and the SP2 for a period of time (O FF-TIME) when the SP2 is in the Idle state (i.e. nothing happening). During the OFF period current is reduced to the device leakage of <50 µA typ. The SP2 will still respond immediately to a Host TX Request but cannot receive radio signals. After the programmed O FF-TIME the SP2 will wake itself up, turn the receiver on and listen for valid preamble. ON time = PWR->RX (EEPROM address 05h) + 2.5ms = 3.3ms (using SP2 Default values) If preamble is found the SP2 will stay ON and decode the packet, if not the SP2 will shut down for another OFF time period. Also see - WAKE-UP (address 02h of EEPROM) and paragraph 2.3.2 . figure 11: Switches

Radiometrix Ltd, SP2 data sheet page 12 PS1 PS0 0 0 CONTINUOUS 20mA (no power saving) 0 1 POWER SAVE programmable sleeptime * 1 0 SLEEP < 460µA (fixed off time of 181ms) 1 1 OFF < 50µA Transceiver is off ( reset or TXR to wake-up) * Sleeptime programmable in EEPROM address 03h. value off -time Average current 22ms 45ms 90ms 181ms 2.95 mA 1.60 mA 0.85 mA 0.46 mA The supply current's quoted above are typical for a BiM2 + SP2 using the EEPROM default values.

3.2 HTO & RTO - I

Both the Host and the Radio interfaces can 'hang' the SP2 while it waits for an external event. Under error conditions the SP2 will reset itself if the appropriate HTO or RTO switch is set. RTO RADIO TIME OUT. 0 no time out 1 Time-Out and reset if > 2.9s of plain preamble detected. (note. valid extended preamble used for wake-ups will not cause a Time-Out to be detected) HTO HOST TIME OUT 0 no time out

1 Time-Out and reset if Host fails to reply to any request or handshake

within 2.9s

3.3 WE - EEPROM W

This bit protects the EEPROM from accidental writes, it must be set to 1 prior to each byte write to the EEPROM (addresses 01h to 3Fh). This bit will be cleared by the SP2 after each byte write.

3.4 ST - R

Do not use. Reserved for future use.

3.5 LBT & DBT - C

Listen Before Transmit, LBT, and Delay Before Transmit, DBT determine what collision avoidance the SP2 will take before each transmission. LBT DBT Function 0 0 Immediate TX, no channel check 0 1 Fixed delay TX, no channel check (time slots) This is useful for rapid polling of up to 255 units by a master station. SLOTS is set to the units ID number, the packet size, preamble length and change over delay must be the same for all units being polled. see - EEPROM parameters 1 0 Immediate TX, if channel is clear The receiver is turned on and the channel checked for preamble or data. The SP2 will only go to transmit when the channel is clear. 1 1 Random delay TX, if channel is clear This mode is useful in random access networks where there is a high statistical probability that more than 2 SP2s could be attempting to transmit at the same time. The receiver is turned on and the channel is checked for preamble or data. If the channel is clear the SP2 will go to transmit, if the channel is busy the SP2 will delay by a random time (setable by TX-BACK-OFF in EEPROM) then try again for a clear channel.

Radiometrix Ltd, SP2 data sheet page 13

4.0 USER CONFIGURABLE PARAMETERS IN EEPROM

The EEPROM has address range 01h - 3Fh (63 Bytes) The first 15 BYTES (8 are defined) contain parameters used to control the SP2. figure 12: SP2’s EEPROM memory Def.=FF Def.=FF Def.=FF User EEPROM User EEPROM User EEPROM User EEPROM 00 (RAM)H 01H 02H 03H 04H 05H 06H 07H 08H 0EH 0FH 10H 11H 3DH 3CH 3FH 3EH PS1 PS0 HTO RTO WE ST LBT DBT # Preamble Cycles Wake Up Time Sleep Time RX Power Up Time TX back-off Time TX RX Delay Slot Number Reset State Switches Def.=8C Def.=FF Def.=03 Def.=2C Def.=08 Def.=03 Def.=00 Def.=00 (01-FF) (01-FF) (00-07) (01-FF) (01-FF) (00-07) (00-FF) Reserved Reserved User EEPROM User EEPROM User EEPROM Reserved Reserved RPC registors EEPROM Reserved EEPROM User EEPROM Def.=54 Def.=FF Def.=FF Def.=FF Def.=FF Def.=FF Def.=FF Def.=FF Def.=FF

Radiometrix Ltd, SP2 data sheet page 14 P REAMBLE Number of "01" preamble cycles on TX packets One '01' cycle takes 12.5µs @ 160kbit/s address 01 default 8C formula Preamble time = P REAMBLE * 0.0125ms valid range 01 to FF W AKE-UP Number of units of 'WAKE-UP PREAMBLE + PLEASE HOLD LINE' To be sent as extended preamble to wake-up a remote SP2 in power save mode. W AKE-UP should be set to approx. 1.5 times the remote units OFF Time address 02 default 53 formula Wake-up message = WAKE-UP * 3.24ms valid range 01 to FF S LEEP-TIME Power Save 'Off' Time (RC controlled) The OFF time is controlled by an RC oscillator in the SP2 which has a wide tolerance of +/- 30% address 03 default 03 formula Off-time = 22 * 2 SLEEP-TIME ms valid range 00 to 03 RX ↔↔↔↔ TX TX ↔↔↔↔ RX change over delay in units of 100µµµµs address 04 default 2C formula Delay = RX ↔ TX * 12.5µs valid range 01 to FF PWR →→→→ RX RX stabilisation delay in units of 100µµµµs address: 05 default: 8 formula: Delay = PWR → RX * 0.1 ms valid range: 01 to FF TX-B ACK-OFF Maximum TX Back-off delay in units of 1ms Used when LBT=1 & DBT=1 address 06 default 03 formula maximum delay = (2 TX-BACK-OFF - 1) ms valid range 00 to 07 00 = 0 - 1 ms 01 = 0 - 3 ms 02 = 0 - 7 ms 03 = 0 - 15 ms 04= 0 - 31 ms 05 = 0 - 63 ms 06 = 0 - 160 ms 07 = 0 - 255 ms

Radiometrix Ltd, SP2 data sheet page 15 TX-SLOT 0 - 255 slot number for delayed (polled) TX Delayed TX in packet units, used when LBT=0 & DBT=1 address 07 default 00 formula delay = TX-Slot * (Preamble*0.0125 + Tpacket + 3*RX ↔ TX + 0.5) ms where Tpacket = (Number of bytes in packet +2) * 0.075ms valid range 00 to FF R ESET STATE RESET STATE OF SWITCHES The contents of this address are copied into SWITCHES on SP2 reset, power-up or watchdog Time-Out address 08 default 00 Address 09 to 0F are reserved for future and should not be used by the H OST EEPROM Addresses 10 TO 3F (48 BYTES) are free for H OST use as general storage. 5.0 D IAGNOSTIC / DEBUG TEST MODES These special test modes are useful for system testing and debugging To select these modes the SP2 should be released from reset with the TXR line held low, normal SP2 operation will resume when the TXR is set high, i.e. TXR should be held low while in these test modes. note: For normal operation of the SP2 the TXR line must be held high for either 1ms after a reset pulse or 100ms after a power up. There are 8 test modes which are selected by a binary code applied to the SP2's data bus. A 4 bit DIL switch or rotary HEX switch connected between the data bus and 0V will select the modes (the SP2 has weak internal pull-up's). Alternatively the HOST may select the test modes by holding TXR low, resetting the SP2 and driving the required test mode code onto the data bus. note: The SP2 continuously monitors the mode selected i.e.. a reset is not required on mode changes. figure 13: diagnostic mode selection timing diagram

Radiometrix Ltd, SP2 data sheet page 16 In some modes the RXR output from the SP2 is driven low to indicate 'pass' or 'OK'. An LED + 1kΩ from RXR to 5V is recommended. Mode Name Function

0 RX-ON PREAMBLE DETECTOR ON (RXR RED LED = preamble detected)

1 RX-PULSE 10ms ON : 10ms OFF, PREAMBLE DETECTOR ON RXR LED

2 TX-ON-PRE Preamble Modulation - send continuous preamble

3 TX-ON-SQ 100Hz SQUARE WAVE MOD - TX testing on spec. Analyser

4 TX-ON-255 random 160kbit/s data for EYE DIAGRAM tests, sync's on RXR

5 TX-PULSE PREAMBLE BURSTS (EE 01 SETTING): 10ms OFF, RX lock in tests

6 ECHO TRANSPONDER MODE, re-transmit any valid packets received

7 RADAR Send ASCII TEST PACKET "RADIOMETRIX" and listen for echo

Modes 6 & 7 are particularly useful for software debugging and range testing. SP2 +5V OK TXSignal RX Test Mode Select Switches Reset +5V Ω TXA RX select TX select SIGNAL TXR RXA RXR Antenna 470Ω 470Ω 470Ω D3 D2 D1 D0 Mode 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 0 1 0 0 4 0 1 0 1 5 0 1 1 0 6 0 1 1 1 7 figure 14: stand-alone diagnostic mode

Radiometrix Ltd, SP2 data sheet page 17 APPENDIX - A A Detailed look at the SP2's transceiver interface The SP2 interfaces to the transceiver using 4 lines :- TX output Active low enable for the transmitter. TXD output Serial data to be sent. RX output Active low enable for the receiver. RXD input Received serial data. note 1 All lines are 5V CMOS levels note 2 There is no requirement for a carrier/signal detect signal from the transceiver nor for the RXD output to be muted when no signal is present. The enable lines - TX & RX These normally high, active low lines are used to control the transceiver. The SP2 is a half-duplex controller thus in normal operation the transceiver is either transmitting or receiving or off. Transmit Data - TXD TXD is the serial data to the transmitter, it is held low when the transmitter is not enabled. When the TX is enabled a synchronous 160kbit/s (6.25µs/bit) serial code is present to modulate the transmitter. Receive Data - RXD RXD is a hi-impedance input which is fed with a 'squared-up' (5V logic level) signal from the receivers' data slicer. The SP2 contains a very selective, noise immune signal detector and therefor does not require that the RXD signal be muted in the absence of signal, i.e.. squared-up channel noise may be fed to the SP2 when no signal is present. The SP2's Packet Encoder The packet is made-up of 4 parts: Preamble This is a simple 80kHz square wave, the number of cycles being programmed by address 01h of the EEPROM. The preamble has two functions, the initial portion it is used to allow the data slicer in a remote receiver to establish the correct slicing point (for the BiM2-433-160 this takes a maximum of 0.8ms), after the receiver has settled, the remaining portion is used by the receiving SP2 to positively identify and phase lock onto the incoming the signal (this requires 12 cycles of preamble). The preamble may extended to wake-up a remote SP2 in power saving mode. Frame sync A 7 bit Barker sequence is used to identify the start of the data. Alternatively if the transmitter is sending extended preamble (to wake a power saving remote SP2) a complimented 7 bit Barker sequence is sent every 256 preamble cycles as a 'Please Hold The Line' code. An 8th balancing bit is added after the Barker sequence.

Radiometrix Ltd, SP2 data sheet page 18 Data Each byte in the SP2's buffer is expanded into a 12 bit symbol prior to sending. The symbol coding has the following properties :-

  • Perfect 50:50 balance, i.e.. always 6 one's & 6 zero's
  • There are never more than 4 consecutive one's or zero's. This minimises the low frequency components in the code and allows fast settling times to be used for the receivers' data slicer.
  • Minimum Hamming distance = 2, i.e.. each code is different from any other code by a minimum of 2 bits, thus all odd number of bit errors will always be detected. byte error.
  • Preamble and the Frame sync codes are not part of the symbol alphabet, a 'clash' signal will cause immediate termination of the current decode followed by an attempt to lock to the new signal. Check Sum Since the receiver checks each symbol for integrity, a simple 8 bit check sum is used to test for overall packet integrity. This is also coded into a 12 bit symbol prior to transmission.

Radiometrix Ltd, SP2 data sheet page 19 The SP2's Packet Decoder Signal Decoding is in 4 stages :- Search Initially the SP2's decoder searches the radio noise on the RXD line for the 80kHz preamble signal. The search is performed by a 16 times over-sampling detector which computes the spectral level of 80kHz in 192 samples of the RXD signal (156µs window).If the level exceeds a pre-set threshold the decoder will attempt to decode a packet. Lock-in The same set of 192 samples are used to compute the phase of the incoming preamble and synchronise the internal recovery clock to an accuracy of +/- 2µs. The recovery clock samples the mid point of each incoming data bit and shifts the samples trough an 8 bit serial comparator. The comparator searches the data on a bit by bit basis for the frame sync byte. While the search is in progress, the decode will abort if the preamble fails to maintain a certain level of integrity. If the comparator finds the 'please hold the line' code used during extended wake-up preamble a phase re-lock is triggered to ensure accurate phase tracking until the actual packet arrives. When the frame sync is detected the decoder attains full synchronisation and will move to the Decode state. Decode Data is now taken in 12 bits at a time (one symbol), decoded into the original byte and placed in the receive buffer. The symbol decoder verifies each received symbol as valid (only 256 out of a possible 4096 are valid) and will immediately abort the decode on a symbol failure. The first byte contains the byte count and is used to determine the end of message. Check Sum The last byte is the received check sum, this is verified against a locally generated sum of all the received bytes in the packet. If it matches the packet is valid and RXR line will be pulled low to inform the Host that a packet awaits uploading. Notes on error handling The SP2’s' decoder is deliberately non bit error tolerant, i.e.. no attempt is made to repair corrupt data bits. All of the redundancy in the code is directed towards error checking. For an FM radio link using short packet lengths, e.g. SP2 + BiM2 , packets are either 100% or so grossly corrupt as to be unrecoverable. By the same reasoning, the Host is not informed when the SP2 decoder aborts a packet decode since corrupt information is of little value. A packet acknowledge Time-Out and re-transmission is the preferred strategy for error handling.

Radiometrix Ltd, SP2 data sheet page 20 APPENDIX - B Example SP2 driver subroutines for Arizona PIC16C73 TXA TXR RXA RXR PB7 PB6 PB5 PB4 PB3 PB2 PB1 PB0 / IRQ SP2 PIC HOST Packet transfers to / from the SP2 are best handled in the host by two subroutines :- OUT_BYTE & IN_BYTE Additionally LISTEN_BUS is called on completion of a packet transfer to the SP2 to return the data bus to inputs (default state). ; SP2 DRIVERS ; HOST PROCESSOR PIC16C73 or similar SP2 EQU 06 ;USE PORT B ON PIC ; Bit assignments for SP2 PORT D7 EQU 7 ;Bi-Dir D6 EQU 6 ;Bi-Dir D5 EQU 5 ;Bi-Dir D4 EQU 4 ;Bi-Dir TXA EQU 3 ;INPUT TXR EQU 2 ;OUTPUT RXA EQU 1 ;OUTPUT RXR EQU 0 ;INPUT ON RB0, CAN BE CONFIGURED AS AN INTERRUPT SP2_DDR 86 ;Data direction register for port B (SP2) ; ;This register is in BANK 1 of the register file W EQU 0 ;Accumulator as Destination F EQU 1 ;Register File as Destination INDF EQU 00 ;INDirect File register figure 15: SP2 to PIC µµµµ-C interface

Radiometrix Ltd, SP2 data sheet page 21 ;SUBROUTINE IN_BYTE ;IN_BYTE READ A BYTE FROM THE SP2 INTO FILE POINTED TO BY FSR ; W IS DESTROYED ; NOTE THIS ROUTINE WILL HANG THE HOST UNTIL THE HOST ; COMPLETES THE TRANSFER OF TWO NIBBLES ; THIS SUBROUTINE CAN BE CONFIGURES TO RUN AS PART OF ANINTERRUPT HANDLER IF THE :RXR LINE FROM THE SP2 : IS USED TO TRIGGER A HOST INTERRUPT IN_BYTE BTFSC SP2,RXR ;WE GOT A RX REQUEST YET? GOTO IN-BYTE ;NO , SO LOOP BACK AND WAIT ; READ THE LS NIBBLE FROM THE SP2 BCF SP2,RXA ;ACCEPT THE REQUEST (SET ACCEPT LOW) AWAITDATA BTFSS SP2,RXR ;HAS REQUEST GONE UP? data is present GOTO AWAITDATA ;LOOP BACK TILL IT DOES NOP ;TIME DELAY TO ENSURE DATA STABLE ; ;BEFORE READ MOVF SP2,W ;READ THE LS NIBBLE FROM THE BUS BSF SP2,RXA ;TELL SP2 WE GOT NIBBLE (ACCEPT = 1) ANDLW B'11110000' ;JUST THE DATA MOVWF INDF ;SAVE LS NIBBLE IN TARGET FILE (VIA ; ;FSR) SWAPF INDF ;RIGHT JUSTIFY LS NIBBLE ; NOW GET MS NIBBLE FROM THE SP2 INNIBBLE BTFSC SP2,RXR ;WE GOT NEXT RX REQUEST YET ? GOTO INNIBBLE ;NO , SO LOOP BACK AND WAIT BCF SP2,RXA ;ACCEPT REQUEST (SET ACCEPT LOW) AWAITD1 BTFSS SP2,RXR ;HAS REQUEST GONE UP? data is present GOTO AWAITD1 ;LOOP BACK TILL IT DOES NOP ;TIME DELAY TO ENSURE DATA STABLE ; ;BEFORE READ MOVF SP2,W ;READ THE MS NIBBLE FROM THE BUS BSF SP2,RXA ;TELL SP2 WE GOT NIBBLE (ACCEPT=1) ANDLW B'11110000' ;JUST THE DATA IORWF INDF ;COMBINE MS NIBBLE WITH LS NIBBLE ;ALREADY ; ;IN THE FILE (VIA FSR)RETURN ; A BYTE HAS BEEN READ FROM THE SP2 INTO ADDRESS POINTED AT BY FSR

Radiometrix Ltd, SP2 data sheet page 22 ;SUBROUTINE OUT_BYTE ;OUT_BYTE WRITE A BYTE FROM FILE POINTED TO BY FSR TO SP2 ; W IS DESTROYED ; NOTE THIS ROUTINE WILL HANG THE HOST UNTIL THE SP2 ; ACCEPTS THE TRANSFER OF TWO NIBBLES ; WARNING OUT_BYTE WILL SET THE DATA BUS TO DRIVE AFTER ; DETECTING A TXA FROM THE SP2. ; THE CALLING ROUTINE MUST SET 4 DATA LINES ; BACK TO I/P ON COMPLETION OF PACKET TRANSFER ; (i.e. call LISTENBUS) OUT_BYTE SWAPF INDF,W ;GET LS NIBBLE FROM FILE (VIA FSR) INTO ; ;BITS 4 to 7 of W ANDLW B'11110000' ;JUST THE NIBBLE IORLW B'00000010' ;SET TXR LOW, LEAVE RXA HIGH MOVWF SP2 ;SET TXR LOW, OUTPUT NIBBLE WACCEPT BTFSC SP2,TXA ;WE GOT A TX ACCEPT BACK YET? GOTO WACCEPT ;NO, SO LOOP BACK AND WAIT ;WE GOT ACCEPTANCE SO IT'S OK TO DRIVE BUS BSF STATUS,RP0 ;SELECT PAGE 1 MOVLW B'00001001' ;DRIVE BUS MOVWF SP2_DDR BCF STATUS,RP0 ;SELECT PAGE 0 BUS IS NOW DRIVING BSF SP2,TXR ;REMOVE REQUEST, DATA IS ON BUS WDUN BTFSS SP2,TXA ;HAS DATA BEEN READ? GOTO WDUN ;WAIT TILL SP2 REMOVES ACCEPT ;LS NIBBLE OF (FSR) IS SENT , NOW DO MS NIBBLE MOVF INDF,W ;GET MS NIBBLE FROM FILE (VIA FSR) ANDLW B'11110000' ;JUST THE MS NIBBLE IORLW B'00000010' ;SET TXR LOW (BIT 2), RXA STAYS HIGH MOVWF SP2 ;OUTPUT NIBBLE + TXR LOW WACCEPT1 BTFSC SP2,TXA ;WE GOT A TX ACCEPT BACK YET? GOTO WACCEPT1 ;NO, SO LOOP BACK AND WAIT BSF SP2,TXR ;REMOVE REQUEST, DATA IS ON BUS WDUN1 BTFSS SP2,TXA ;HAS DATA BEEN READ? GOTO WDUN1 ;WAIT TILL SP2 REMOVES ACCEPT RETURN ; BYTE IS SENT TO SP2 ; SUBROUTINE - LISTEN_BUS , SET DATA BUS TO INPUT LISTEN_BUS BSF STATUS,RP0 ;SELECT PAGE 1 MOVLW B'11111001' ;BUS TO INPUT MOVWF SP2_DDR BCF STATUS,RP0 ;SELECT PAGE 0 RETURN ; BUS IS LISTENING TO SP2

Radiometrix Ltd, SP2 data sheet page 23 APPENDIX - C Example SP2 driver subroutines for Motorola 68HC11 TXA TXR RXA RXR PC3 PC2 PC1 PC0 PC7 PC6 PC5 PC4 HC11 HOST IRQ Packet transfers to / from the SP2 are best handled in the host by two subroutines :- OUT_BYTE & IN_BYTE Additionally LISTEN_BUS is called on completion of a packet transfer to the SP2 to return the data bus to inputs (default state). * CPU REGISTER EQUATIONS * *This section contains a few of the necessary register equations used *in the example subroutines. PORTC EQU $1003 ;ADDRESS OF SP2 PORT DDRC EQU $1007 ;DATA DIRECTION REGISTER PORT-C * Port-C7 = RX-accept OUTPUT * Port-C6 = RX-request INPUT * Port-C5 = TX-accept INPUT * Port-C4 = TX-request OUTPUT * Port-C3 = SP2 data bit-3 * Port-C2 = SP2 data bit-2 * Port-C1 = SP2 data bit-1 * Port-C0 = SP2 data bit-0 figure 16: SP2 to HC11 µµµµ-C interface

Radiometrix Ltd, SP2 data sheet page 24 * RANDOM ACCESS MEMORY * ORG RAM ;RAM AREA DEFINITION SAVE_1 RMB 1 ;TEMPORARILY SAVE LOCATION 1 SAVE_X RMB 2 ;HOLDS FILES POINTER FOR IN_BYTE * SUBROUTINE: IN_BYTE * *This subroutine is designed to be called by an interrupt handler to *read a byte from the SP2 into a file pointed at by X *Note: The interrupt handler should load the X register with the file address before calling this subroutine. IN_BYTE CLR SAVE_1 ;CLEAR TEMPORARILY MEMORY LOCATION LDAB #%10010000 ;SET CORRECT DATA DIRECTION i/p STAB DDRC WAIT_RQ LDAB PORTC ;WAIT FOR RX-REQUEST TO GO LOW BITB #%01000000 ; BNE WAIT_RQ IN_LP LDAB PORTC ANDB #%01111111 ;FORCE RX-ACCEPT TO GO LOW STAB PORTC WAIT_RQ1 LDAB PORTC ;WAIT FOR RX-REQUEST TO GO HIGH BITB #%01000000 BEQ WAIT_RQ1 DAT_IN LDAA PORTC ;READ IN DATA ANDA #%00001111 LDAB PORTC ;FORCE ACCEPT HIGH ORAB #%10000000 STAB PORTC STAA SAVE_1 ;SAVE NIBBLE TO TEMP LOCATION WAIT_RQ2 LDAB PORTC ;WAIT FOR RX-REQUEST TO GO LOW BITB #%01000000 BNE WAIT_RQ2 IN_LP2 LDAB PORTC ANDB #%01111111 ;FORCE RX-ACCEPT TO GO LOW STAB PORTC WAIT_RQ3 LDAB PORTC ;WAIT FOR RX-REQUEST TO GO HIGH BITB #%01000000 BEQ WAIT_RQ3 DAT_IN2 LDAA PORTC ;READ IN DATA ANDA #%00001111 ASLA ASLA ASLA ASLA LDAB PORTC ;FORCE ACCEPT HIGH ORAB #%10000000 STAB PORTC ORAA SAVE_1 ;PUT NIBBLES TOGETHER IN TEMP LOCATION STAA SAVE_1 READ_END STAA 0,X ;SAVE DATA TO POINTER ADDRESS

Radiometrix Ltd, SP2 data sheet page 25 * SUBROUTINE: OUT_BYTE *This subroutine will output of one byte to the SP2. Register X *should contain the address of the memory location of the byte to be *send. *Note: that register X has to be pre-loaded before entering this * subroutine. OUT_BYTE LDAA 0,X ;GET THE BYTE TO SEND TO SP2 ANDA #%00001111 ;PREPARE LEAST SIGNIFICANT NIBBLE LDAB PORTC ANDB #%11101111 ;FORCE TX-REQUEST LOW STAB PORTC WAIT_ACC LDAB PORTC BITB #%00100000 ;WAIT FOR TX ACCEPT TO GO LOW BNE WAIT_ACC LDAB #%10011111 ;CHANGE DATA DDRC TO OUTPUT STAB DDRC ;TURN BUS DRIVE ON ORAA #%10000000 ;MAKE SURE RXA IS HIGH STAA PORTC ;OUTPUT DATA LDAB PORTC ORAB #%00010000 ;FORCE TX-REQUEST HIGH STAB PORTC WAIT_REQ LDAB PORTC ;WAIT FOR TX_ACCEPT TO GO HIGH BITB #%00100000 BEQ WAIT_REQ LDAA 0,X ;PREPARE MOST SIGNIFICANT NIBBLE LSRA ;BY SWAPPING THE LS- & MS-NIBBLE LSRA LSRA LSRA LDAB PORTC ANDB #%11101111 ;FORCE TX-REQUEST LOW STAB PORTC WAIT_TXA1 LDAB PORTC ;WAIT FOR TX-ACCEPT TO GO LOW BITB #%00100000 BNE WAIT_TXA1 ORAA #%10000000 STAA PORTC ;OUTPUT DATA LDAB PORTC ORAB #%00010000 ;FORCE TX-REQUEST HIGH STAB PORTC WAIT_TXR1 LDAB PORTC ;WAIT FOR TX_ACCEPT TO GO HIGH BITB #%00100000 BEQ WAIT_TXR1 RTS * SUBROUTINE: LISTEN TO BUS *This will turn the SP2 host to listen mode again and should *be called when the whole packet has been sent to the SP2 LISTEN_BUS LDAA #%10010000 ;PUT PORT BACK TO LISTEN STAA DDRC RTS

Radiometrix Ltd, SP2 data sheet page 26 APPENDIX - D The FRPC as a control IC Clock frequency All timings within the SP2 (except sleep) are determined by the clock frequency. The standard frequency is 20.48MHz and all timings unless explicitly stated otherwise, assume this clock frequency. 128 clkfratedataThe = bits/s ( i.e. 160kbit/s for F clk=20.48MHz) Clock accuracy The SP2 uses synchronous data transmission and requires an accurate reference clock. In the worst case , max. preamble and packet length, the allowable bit rate timing error between transmitter and receiver is 0.2 bits in 1000 bits, i.e. +/-200ppm total or +/-100ppm at each end. xtalfTimeBit 128= Hz i.e. 20.48MHz crystal = 6.25 µs PER BIT Accuracy, temp drifts MUST KEEP X-TAL +/- 100ppm of nominal

231 Kenton Lane

Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000. R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/radiocomms/ifi/licensing/licensing_policy_manual/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)845 456 3000 or 020 7981 3040 Fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk European Radiocommunications Office (ERO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk