SMX2-433-5 RADIOMETRIX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Features

! Conforms to ETSI EN 300 220-3 and EN 301 489-3 ! High performance double superhet, 128 channel PLL synthesizer ! Data rates up to 5 kbps for standard module ! Usable range over 500m ! Fully screened. Low profile ! Feature-rich interface (RSSI, analogue and digital baseband) ! Incorporate a 1200baud dumb modem ! Re-programmable via RS232 interface ! Low power requirements

Applications

! Handheld terminals ! Heavy vehicle/machine remote controls ! EPOS equipment, barcode scanners ! Data loggers ! Industrial telemetry and telecommand ! In-building environmental monitoring and control ! High-end security and fire alarms ! Vehicle data up/download Technical Summary ! Operating frequency: 433.05 - 434.79MHz ! Custom variants from 431 - 436MHz on any 1MHz band ! 128 channels controlled via RS232 interface ! Transmit power: +10dBm (10mW) nominal. Adjustable 2 – 25mW ! Supply range: 4.2V - 15V ! Current consumption: 30mA (10mW) transmit, 25mA receive ! Data bit rate: 5kbps max. (standard module) ! Receiver sensitivity: -120dBm (for 12 dB SINAD) ! Size: 53 x 32 x 12mm Small MultiSmall MultiSmall MultiSmall Multi----channel UHF Transceiverchannel UHF Transceiverchannel UHF Transceiverchannel UHF Transceiver SMX2 is small multi -channel UH F transceiver operating on 433.05MHz- 434.79MHz European licence exempt band. SMX2 offers a fast-route to custom frequency on any UHF band from 431MH z to 436MHz with 25kHz channel spacing. Radiometrix Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England Issue 1, 28 August 2007 S M X 2 NEW Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233 Figure 1: SMX2-433-5

Radiometrix Ltd SMX2 Data Sheet page 2 Figure 2: SMX2 block diagram

Radiometrix Ltd SMX2 Data Sheet page 3 Pin Name Function 1a RSSI DC level between 0.5V and 2.5V. 60dB dynamic range 2a Vcc DC supply input. (4.2 – 15V at 50mA max.) 3a TXD DC coupled input for TTL/ CMOS logic. 4a AF out 500mV p-p audio. DC coupled, approx 0.8V bias. 5a RXD Open collector output of data slicer. Need external pull-up 6a TXE Transmit enable. Low = RX mode. High = TX. (10kΩ pull down) 7a PGM Serial programming / control input (true RS232) 8a 0V Ground 1b 0V Ground 2b S0 Parallel channel select LSB 3b S1 Parallel channel select 4b S2 Parallel channel select MSB Pin description of SMX2 with Modem mode selected The 'modem' mentioned is a 1200 baud RS232 semi-intelligent unit (Transmit keyed when valid serial data is present, so no separate TX control needed. Coding in the datastream also permits the receiver to ignore noise and only output valid serial data) This is a half duplex unit, so collisions between transmitted and received packets must be dealt with by the user (if transmit data is sent to the unit then a transmit burst commences immediately and the contents of the receive data buffer is lost) Pin Name Function 1a RSSI DC level between 0.5V and 2.5V. 60dB dynamic range 2a Vcc DC supply input. (4.2 – 15V at 50mA max.) 3a NC Leave unconnected 4a NC Leave unconnected 5a MOD RXD Open collector RS232 compatible data output 6a MOD TXD RS232 data input 7a PGM Serial programming/control input (true RS232) 8a 0V Ground 1b 0V Ground 2b S0 Parallel channel select LSB 3b S1 Parallel channel select 4b S2 Parallel channel select MSB NOTES: 1. No inversion occurs between TXD and RXD. However AF out is inverted relative to TXD. 2. Parallel channel selects are active LOW and have internal pullups to 4V 3. There are no pullups on the open collector outputs. 4. The software incorporates a 1200 baud modem, compatible with that implemented in other Radiometrix narrowband units ( i1200 tones and format ). Modem operation is selected by the SETMOD command. TXE pin (6a) becomes an RS232 input, and RS232 compatible data is output on the RXD pin (5a). If true +/- levels are desired then an inverter and a MAX232 should be used on data out. Figure 3: SMX2 footprint (Top) view Pin Description

Radiometrix Ltd SMX2 Data Sheet page 4 5. RS232 input pins (6a and 7a) tolerate true +/- levels. No buffering is required. 6. If analogue transmit modulation is needed, then connect a series 1 µF cap + 500kΩ trimmer in the ‘baseband in’ circuit. Adjust trimmer for 90% of peak deviation (+/- 2.7KHz) at mean input level. 7. If parallel channel select is not wanted, the 4 pin connector 'b' can be removed SMX2 serial interface commands 2400 baud at RS232 level. 8 bit data, no parity, 1 start bit, 1 or 2 stop bits, No flow control. Transmit (pin 3 on DB9) and Signal Ground (pin 5 on DB9) should be connected to PGM and 0V respectively. SINGLE nnnnn Set value of N for single channel operation (value not stored in eeprom) GOCHAN xx Serial select of channel xx (0 to 127) LOADMX xx Set highest permitted (serial selected) channel xx (others default to ch0) LOAD aa nnnnn Set value of N for channel aa (channels 0 to 15) LOADTB nnnnn Set value of N for channel 16 (channels 17 to 127 then in sequence) RVALUE rrrr Enter value for R register SETPAR Channel selected by 3 bit parallel input (0 to 7). Also disables modem SETSER Channel selected by most recent 'gochan' operation SETMOD Enable internal modem. Frequency selected by most recent 'gochan' or 'single' <cr> Process entry / Clear all buffers xx = channel number from 00 to 127 aa = two digit channel number from 00 to 15 nnnnn = synthesizer N register value, (up to 65535) rrrr = synthesizer R register value, (up to 16383) 1732225 05.433 === kHz MHz f fN cingChannelspa RF kHz MHz f fR cingchannelspa Xtal 13== , So R=520 Notes: 1. A pause of at least 50ms must be allowed between command strings (EEPROM programming time). SINGLE mode does not store the N value in EEPROM. Therefore the unit is inoperative after a power down until either another valid SINGLE command is received, or mode is changed by a GOCHAN, SETPAR or SETSER command. SINGLE mode is intended for frequency agile applications. 2. /SETPAR command should be issued at the end of channel programming to put the module back into parallel frequency select mode

Radiometrix Ltd SMX2 Data Sheet page 5 Condensed specifications Frequency 433.05 - 434.79MHz (Any 1MHz band from 431 - 436MHz) Frequency stability ±2kHz Channel spacing 25kHz (12.5kHz by special order) Number of channels 128 channels selected via serial RS232 interface 8 channels parallel selected (via 3 frequency select pins) in 433MHz band only 69 channels are used as standard Supply voltage 4.2V-15V Current 30mA @ 10mW transmit [ 25mW version @ 45mA] 25mA receive (or modem ‘idle’) Operating temperature -10 to +60 C (Storage -30 to +70 C) Size 53 x 32 x 12 mm Spurious radiations Compliant with ETSI EN 300 220-3 and EN 301 489-3 Interface user 8 pin 0.1" pitch molex Power 4 pin 0.1" pitch molex RF 3 pin 0.1" pitch molex Recommended PCB hole size 1.2mm (min.) Transmitter Output power +10dBm(10mW) ± 1dB (factory adjustable: 2 - 25mW) TX on switching time <50 ms Modulation type FM, FSK (F1D, F3D) TX modulation bandwidth DC – 3kHz Deviation ±3kHz Adjacent channel TX power -37dBm TX spurii <-45dBm Inputs Data (CMOS/TTL compatible) Receiver Sensitivity -120dBm for 12dB SINAD -112dBm for 1 part per 1000 BER image / spurious -60dB blocking -85dB adjacent channel -60dB (Tested per. ETSI EN 301 489-3) Outputs RSSI, Audio, Data Power on to valid audio 28ms Power on to stable data out 50ms (for 50:50 mark / space) Notes: 1. The data slicer cannot be depended upon for data waveform frequencies below 250Hz 2. When RX is on and a transmitter keys up, again a 50ms period is required to stabilise data output mark/space. i.e. allow at least 50ms of preamble

Radiometrix Ltd SMX2 Data Sheet page 6 Application circuits RSSI (1a) Vcc (2a) TXD (3a) AF (4a) RXD (5a) TXE (6a) PGM (7a) 0V (1b) S0 (2b) S1 (3b) S2 (4b) 1kΩ 1kΩ 1kΩ RX TX Microcontroller SMX2

3 TXD

4.2-16V Figure 4: SMX2 interfaced to host microcontroller and serial port for configuration RSSI (1a) Vcc (2a) TXD (3a) AF (4a) MOD RXD (5a) MOD TXD (6a) PGM (7a) 0V (1b) S0 (2b) S1 (3b) S2 (4b) SMX2 (for 5V) Figure 5: SMX2 interfaced to PC serial port (0V / 5V RS232 level) RSSI (1a) Vcc (2a) TXD (3a) AF (4a) MOD RXD (5a) MOD TXD (6a) PGM (7a) 0V (1b) S0 (2b) S1 (3b) S2 (4b) SMX2 (for 5V) MAX232 16 (+5V) Figure 6: SMX2 interfaced to serial port (+10V / -10V RS232 level)

231 Kenton Lane

Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in wholeor in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000. R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/radiocomms/ifi/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)845 456 3000 or 020 7981 3040 Fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk European Radiocommunications Office (ERO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk