(See Last Page) © SUMMIT Microelectronics, Inc. 2003 • 300 Orchard City Drive, #131 • Campbell CA 95006 • Phone 408 378-6461 • FAX 408 378-6596 www.summitmicro.com 2070 1.0 7/16/03 1 Six-Channel Power Supply Supervisor and Cacsade Sequence Controller FEATURES & APPLICATIONS

  • Very accurate monitor function – 5mV steps
  • Monitors and sequences up to six supplies
  • Programmable Power-on/-off sequencing
  • Monitors internal temperature sensor
  • Operates from 12V or 3.3V supply
  • Monitors 12V input and VDD
  • Monitors two general-purpose 10-bit ADC inputs
  • Programmable threshold limits (2 OV/2 UV) for each monitored input
  • Programmable RESET, HEALTHY and FAULT functions
  • 4k-bit general purpose nonvolatile memory
  • I2C 2-wire serial bus for programming configuration and monitoring status, including 10-bit ADC conversion results

Applications

  • Monitor and Sequence Distributed Power and Point of Load Power Supplies
  • Multi-voltage Processors, DSPs, ASICs used in Telecom, CompactPCI or server systems INTRODUCTION The SMS66 is a very accurate programmable power supply supervisor that monitors and sequences. It controls sequencing time and position of up to six isolated or non-isolated distributed or POL DC/DC converters. The monitor supervisory function has two independent UV and OV settings for each supply and can be set in 5mV steps. The SMS66 also sequences the power supplies in any order using enable outputs with programmable polarity. The SMS66 monitors six power supply channels as well as VDD, 12V input, two general-purpose analog inputs and an internal temperature sensor using a 10- bit ADC. The 10-bit ADC can measure the value on any one of the input channels and output the conversion data via the I 2C bus. Using the I 2C interface, a host system can communicate with the SMS66 status register, optionally control Power-on /off, and utilize 4 K-bits of nonvolatile memory. SIMPLIFIED APPLICATIONS DRAWING PUPF VMF PUPA VMA SMS66 µP/ DSP/ NPU/ FPGA VDD RST HEALTHY MR VDD (+2.7V to +5.5V Range) RESET DONE HEALTHY 12VIN 12VIN (+8V to +15V Range) External or Internal TEMP SENSOR AIN1 VREF_ADC 2.5VIN 1.2VIN 12V SDA SCLI2C BUS 3.3V VREF_OUT VIN Vout DC/DC Converter A ON/OFF VIN Vout DC/DC Converter F ON/OFF External or Internal REFERENCE Figure 1 – Applications Schematic using the SMS66 Controller to cascade sequence up to six DC/DC Converters while also providing supervisory functions. Note: This is an applications example only. Some pins, components and values are not shown.

Summit Microelectronics, Inc 2070 1.0 7/16/03 2 GENERAL DESCRIPTION The SMS66 is a highly integrated power supply controller, monitor and sequencer. It has the ability to control, monitor and sequence up to six power supplies. Also, the SMS66 can monitor the VDD input, the 12V input, two general-purpose analog inputs and the internal temperature sensor. The SMS66 has three operating modes: Power-on sequencing mode, monitor mode, and Power-off sequencing mode. Power-on sequencing can be initiated via the PWR_ON/OFF pin or I 2C control. In this mode, the SMS66 will sequence the power supply channels on in any order by activating the PUP outputs and monitoring the respective converter voltages to ensure cascading of the supplies. A programmable sequence termination timer can be set to disable all channels if the Power-on sequence stalls. During this mode the HEALTHY output will remain inactive and the RST output will remain active. Once the Power-on sequencing mode is complete, the SMS66 enters monitor mode. In the monitor mode the SMS66 supervises the supplies to within 5mV, and enables the triggering of outputs by monitored fault conditions. The 10-bit ADC cycles through all 11 channels every 2ms and checks the conversions against the programmed threshold limits. The results can be used to trigger RST, HEALTHY and FAULT outputs as well as to trigger a Power-off or a Force Shutdown operation. The Power-off sequencing mode can only be entered while the SMS66 is in the monitoring mode. It can be initiated by either bringing the PWR_ON/OFF pin inactive, through I 2C control or triggered by a channel exceeding its programmed thresholds. Once Power- off is initiated it will disabl e the Active DC Control and sequence the PUP outputs off in either the same or reverse order as Power-on sequencing and monitor the supply voltages to ensure cascading of the supplies as they turn off. The sequence termination timer can be programmed to immediately disable all channels if the Power-off sequencing stalls. The RST output will remain active th roughout this mode while the HEALTHY output remains inactive. Figure 2 – Example Power Supply Sequencing and System Start-up Initialization using the SMS66. Any order of supply sequencing can be applied using the SMS66 with very accurate monitoring and supervisory functions. 2.5V 2.7V 1.8V 2.0V 1.5V VDD (+2.7V to +5.5V) or 12VIN ( +8V to +15V) RST# tPRTO tDPONC tDPONB tDPOND tDPONE tDPONFtDPONA

Summit Microelectronics, Inc 2070 1.0 7/16/03 3 AIN2 10-Bit ADC VREF_ADC AIN1 VMA CAPA VMF CAPF VREF_OUT 12VIN VDD PUPA Sequence Control PUPB PUPC PUPD PUPE PUPF FSPWR_ON/OFF 3.6V or 5.5V Regulator Power Supply Arbitrator Temperature Sensor VDD_CAP Output Control MR RST HEALTHY FAULT Memory and Limit Registers I2C Interface SDA SCL GND Reference Figure 3 –SMS66 Internal Functional Block Diagram. INTERNAL FUNCTIONAL BLOCK DIAGRAM

Summit Microelectronics, Inc 2070 1.0 7/16/03 4 Pin Number Pin Type Pin Name Pin Description

1 DATA SDA I2C Bi-directional data line

2 CLK SCL I2C Clock line

3 IN A2

The address pin is biased either to VDD_CAP or GND. When communicating with the SMS66 over the 2-wire bus A2 provides a mechanism for assigning a unique bus address.

4 IN MR

Programmable active high/low input. When asserted the RST output will be go active. When de-asserted the RST output will go inactive immediately after a reset timeout period (t PRTO) if there are no RST trigger sources active. This timeout period makes it suitable to use a pushbutton for manual reset.

5 IN PWR_ON/OFF

Programmable active high/low input signals the start of the power sequencing. When asserted the part will sequence the supplies on and when de-asserted the part will sequence the supplies off. 6 IN FS Programmable active high/low input. Force shutdown is used to immediately turn off all converter enable signals (PUP outputs)

7 OUT FAULT

Programmable active high/low open drain Fault output. Active when a programmed fault condition exists on AIN1, AIN2, or the internal temperature sensor.

8 OUT HEALTHY

Programmable active high/low open drai n Healthy output. Active when all programmed power supply inputs and moni tored inputs are within OV and UV limits.

9 OUT RST

Programmable active high/low open drain Reset output. Active when a programmed fault condition exists on an y power supply inputs or monitored inputs or when MR is active. RST has a programmable timeout period with options for 0.64ms, 25ms, 100ms and 200ms.

10 IN AIN1 General purpose monitored analog input

11 IN AIN2 General purpose monitored analog input

12, 44, 39, 34, 29, 24, GND GND Ground

13 IN VREF_ADC

Voltage reference input used for A/D conversion where: (4XVREF_ADC) = Full Scale for VMA-F and VDD (12XVREF_ADC) = FS for 12VIN (2XVREF_ADC) = FS for AIN1 and AIN2. VREF_ADC can be connected to VREF_CNTL in most applications. 14 O VREF_OUT Voltage reference output for the internal 1.25V reference. 41,36, 31,26, 21,16 IN VM X Monitored voltage input, VMA through VMF PIN DESCRIPTIONS

Summit Microelectronics, Inc 2070 1.0 7/16/03 5 Pin Number Pin Type Pin Name Pin Description 42,37, 32,27, 22,17 CAP CAP X External capacitor input used to filter the VMX inputs to the 10-bit ADC, CAPA through CAPF. This provides an RC filter where R = 25kΩ. 43,38, 33,28, 23,18 OUT PUP X Programmable active high/low open drain converter enable output, PUP A through PUPF 45, 40, 35, 30, 25, 20, NC NC No Connection

46 PWR VDD Power supply of the part

47 PWR 12VIN 12V power supply input internally regulated to either 3.6V or 5.5V

48 CAP VDD_CAP External capacitor input used to filter the internal supply

PACKAGE AND PIN CONFIGURATION

48 LEAD TQFP

PWR_ON/OFF FS FAULT RST HEALTHY AIN1 GND AIN2 VMB NC GND PUPC CAPC VMC NC GND PUPD CAPD NC VMD VDD_CAP 12VIN VDD NC GND PUPA CAPA VMA NC GND CAPB PUPB VREF_ADC VREF_OUT NC VMF CAPF PUPF GND NC VME CAPE GND PUPE PIN DESCRIPTIONS (Cont.)

Summit Microelectronics, Inc 2070 1.0 7/16/03 6 ABSOLUTE MAXIMUM RATINGS Terminal Voltage with Respect to GND: Note - The device is not guaranteed to function outside its operating rating. Stresses listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions outside those listed in the operational sections of the specification is not implied. Exposure to any absolute maximum rating for extended periods may affect device performance and reliability. Devices are ESD sensitive. Handling precautions are recommended. RECOMMENDED OPERATING CONDITIONS Package Thermal Resistance (θJA) Moisture Classification Level 1 (MSL 1) per J-STD- 020 Note 1 – During an EEPROM memory array or Configuration Register Write, the supply voltage minimum is 3.0V. Note 2 – Range depends on internal regulator set to 3.6V or 5.5V. DC OPERATING CHARACTERISTICS (Over recommended operating conditions, unless otherwise noted. All voltages are relative to GND.) Symbol Parameter Notes Min. Typ. Max Unit VDD Low Range Supply Voltage Note 1 2.7 5.5 V Note 2. Internally regulated to 5.5V 10 15 V 12VIN High Range Supply Voltage Note 2. Internally regulated to 3.6V 7 14 IDD Power Supply Current from VDD 12VIN floating 3 5 mA I12VIN Power Supply Current from 12VIN VDD floating 3 5 mA PTOV1 Programmable Threshold for OV1 condition 0 4XV REF V PTOV2 Programmable Threshold for OV2 condition 0 4XV REF V PTOV1ACC Programmable UV Threshold Accuracy -0.005 PT UV +0.005 V PTOV2ACC Programmable OV Threshold Accuracy -0.005 PT OV +0.005 V PTUV1 Programmable Threshold for UV1 condition 0 4XV REF V PTUV2 Programmable Threshold for UV2 condition 0 4XV REF V PTUV1ACC Programmable UV1 Threshold Accuracy -0.005 PTUV1 +0.005 V PTUV2ACC Programmable UV2 Threshold Accuracy -0.005 PTUV2 +0.005 V Note 1 – During an EEPROM memory array or Configuration Register Write, the supply voltage minimum is 3.0V. Note 2 – Range depends on internal regulator set to 3.6V or 5.5V.

Summit Microelectronics, Inc 2070 1.0 7/16/03 7 DC OPERATING CHARACTERISTICS (CONTINUED) (Over recommended operating conditions, unless otherwise noted. All voltages are relative to GND.) Symbol Parameter Notes Min Typ Max Unit PUP characteristics VOL Output Low Voltage I SINK = 2mA 0 0.4 V All other input and output characteristics VDD = 2.7V 0.9xVDD VDD V VIH Input High Voltage (FS,PWR_ON/OFF, MR#) VDD = 5.0V 0.7xVDD VDD V VDD = 2.7V -0.1 0.1xVDD V VIL Input Low Voltage (FS, PWR_ON/OFF, MR#) VDD = 5.0V -0.1 0.3xVDD V VOL Programmable Open Drain Outputs (RST, HEALTHY, FAULT) ISINK = 2mA 0 0.4 V IOL Output Low Current Note – Total ISINK from all PUPx pins should not exceed 3mA or accuracy specifications will be affected 0 1.0 mA VMMonitor VM Monitor Threshold Step Size VM pins 5 mV VAMonitor AINx Monitor Threshold Step Size AIN1/AIN2 pins 2.5 mV TMonitor Temperature Threshold Step Size Internal Temp Sensor 0.25 oC VREF_OUT Internal 1.25VREF Output Voltage 1.24 1.25 1.26 V VREF TC Internal VREF Temperature Coefficient –5°C to +70°C -0.15 +0.15 % VREF ACC Internal VREF Accuracy -0.4 +0.4 % External VREF External VREF Voltage Range 0.5 VDD_CAP V

Summit Microelectronics, Inc 2070 1.0 7/16/03 8 DC OPERATING CHARACTERISTICS (CONTINUED) (Over recommended operating conditions, unless otherwise noted. All voltages are relative to GND.) Symbol Parameter Notes Min Typ Max Unit AIN1/AIN2 ADC characteristics N Resolution 10 Bits MC Missing Codes Minimum resolution for which no missing codes are guaranteed 10 Bits S/N Signal-to-Noise Ratio Conversion rate = 500Hz 72 db DNL Differential Non-Linearity -1/2 +1/2 LSB INL Integral Non-Linearity -1 +1 LSB GAIN Positive full scale gain error -0.5 +0.5 % Offset Offset Error -1 +1 LSB ZSE Zero Scale Error -1 +1 LSB FSE Full Scale Error -1 +1 LSB ADC_TC Full Scale Temperature Coefficient ±15 PPM /oC IMADC Analog ADC Input Impedance AIN1, AIN2 10 MΩ IIVREF_ADC V REF_ADC Input Current 250 nA ICVREF_ADC VREF_ADC Input Capacitance 200 pF IRVREF_ADC VREF_ADC Input Impedance 1 kΩ

Summit Microelectronics, Inc 2070 1.0 7/16/03 9 AC OPERATING CHARACTERISTICS Over recommended operating conditions, unless otherwise noted. All voltages are relative to GND. See Figure 4B and 4C Timing diagrams. Symbol Description Conditions Min Typ Max Unit 0.64ms 12.5ms 25ms tDPON Programmable Power-on delay from VMX out-of-fault to PUPY active 50ms -15 t DPON +15 % 0.64ms 12.5ms 25ms tDPOFF Programmable Power-off delay from VMX off to PUPY inactive 50ms -15 t DPOFF +15 % 0.64ms 25ms 100ms tPRTO Programmable Reset Time-Out Period 200ms -15 t PRTO +15 % 100ms 200ms tSTT Programmable Sequence Termination Timer 400ms -15 t STT +15 % tADC 10-bit ADC sampling period Time for all 11 channels 2 ms

Summit Microelectronics, Inc 2070 1.0 7/16/03 10 I2C 2-WIRE SERIAL INTERFACE AC OPERATING CHARACTERISTICS - 100/400kHz Over recommended operating conditions, unless otherwise noted. All voltages are relative to GND. See Figure 4A Timing Diagram. 100kHz 400kHz Symbol Description Conditions Min Typ Max Min Typ Max Units fSCL SCL Clock Frequency 0 100 0 400 KHz tLOW Clock Low Period 4.7 1.3 µs tHIGH Clock High Period 4.0 0.6 µs tBUF Bus Free Time Before New Transmission - Note 1/ 4.7 1.3 µs tSU:STA Start Condition Setup Time 4.7 0.6 µs tHD:STA Start Condition Hold Time 4.0 0.6 µs tSU:STO Stop Condition Setup Time 4.0 0.6 µs tAA Clock Edge to Data Valid SCL low to valid SDA (cycle n) 0.2 3.5 0.2 0.9 µs tDH Data Output Hold Time SCL low (cycle n+1) to SDA change 0.2 0.2 µs tR SCL and SDA Rise Time Note 1/ 1000 1000 ns tF SCL and SDA Fall Time Note 1/ 300 300 ns tSU:DAT Data In Setup Time 250 150 ns tHD:DAT Data In Hold Time 0 0 ns TI Noise Filter SCL and SDA Noise suppression 100 100 ns tWR Write Cycle Time Memory Array 5 5 ms tWR Write Cycle Time Configuration Registers 10 10 ms Note: 1/ - Guaranteed by Design. tR tF tHIGH tLOW tSU:SDA tHD:SDA tSU:DATtHD:DAT tSU:STO tBUF tDHtAA SCL SDA (IN) SDA (OUT) tWR (For Write Operation Only) Figure 4A . Basic I2C Serial Interface Timing TIMING DIAGRAMS

Summit Microelectronics, Inc 2070 1.0 7/16/03 13 The SMS66 can be programmed to wait until either or both VDD and 12VIN inputs are within their respective voltage threshold limits before Power-on sequencing is allowed to begin. This ens ures that the converters have their full supply voltage before they are enabled. Once Power-on sequencing begins, the SMS66 will wait a Power-on delay time (t DPON) for any channel in the first sequence position (0) and then activate the PUP X outputs for those channels. The Power-on delay times are individually programmable for each channel. The SMS66 will then wait until all VMX inputs of the channels assigned to the first sequence position (0) are above their programmed UV1 thresholds. At this point, the SMS66 will enter the second sequence position (1) and begin to timeout the Power-on delay times for the associated channels. This process continues until all of channels in the sequence have turned on and are above their UV1 threshold. The status registers indicates that all sequenced power supply channels have turned on. The programmable sequence termination timer can be used to protect against a stalled Power-on sequence. This timer resets itself at the beginning of each sequence position. All channels in the sequence position must go above their UV1 threshold before the sequence termination timer times out (t STT) or the sequence will terminate and all PUP X outputs will be switched to their inactive state. The status registers contain bits that indicate the sequence has been terminated and in which sequence position the timer timed out. This timer has four settings of OFF, 100ms, 200ms and 400ms. While the SMS66 is in the Power-on sequencing mode the RST output is held active and the HEALTHY output is held inactive regardless of trigger sources. The Power-off and Force Shutdown trigger options are also disabled while in this mode. Furthermore, the SMS66 will not respond to activity on the PWR_ON/OFF pin or to a Power-off I 2C command during Power-on sequencing mode. MONITORING Once the Power-on sequence is complete and before a Power-off sequence has been initiated, the SMS66 continues to monitor all VM X inputs, the VDD and 12VIN inputs, and two temperature sensor inputs with a 10-bit ADC. Each of these inputs is sampled and converted by the ADC every 2ms. The ADC input has a range of 0V to four times the voltage on VREF_ADC for inputs VM A-F and the VDD input. The range is extended to 12 times VREF_ADC for the 12VIN input and is reduced to two times VREF_ADC for the AIN1 and AIN2 inputs. The SMS66 monitors internal temperature using the 10-bit ADC and the automonitor function. Two under temperature and two over temperature thresholds can be set, each with its own programmable trigger options and consecutive conversion before trigger counter. Resolution is 0.25 C per bit scaled over the range of -128 C to 127.75 C. The temperature value can also be acquired over the I 2C bus as a 10-bit signed two's complement value. The SMS66 compares each resulting ADC conversion with two programmable 10-bit under-voltage limits (UV1, UV2) and two programmable 10-bit over-voltage limits (OV1, OV2) for the corresponding input. A consecutive conversion count er is used to provide filtering of the ADC inputs. Each limit can be programmed to require 1, 2, 4 or 6 consecutive out-of- limit conversions before it is said to be in fault. One in- limit conversion will remove the fault from the threshold limit. This provides digital filtering of the monitored inputs. The ADC inputs VM A-F can use additional filtering by connecting a capacitor from the corresponding CAPX pins to ground to form an analog RC filter (R=25kΩ). The input is considered to be in a fault condition if any of its limit thresholds are in fault. Setting an OV threshold limit to full-scale (3FF HEX), or setting an UV threshold limit to 000 HEX ensures that the limit can never be in fault. The status registers provide the real-time status of all monitored inputs. The voltage threshold limits for inputs VM A-F, VDD and 12VIN can be programmed to trigger the RST and HEALTHY outputs as well as a Force Shutdown and Power-off operation when exceeded. The threshold limits for the internal temperature sensor and the AIN1 and AIN2 inputs can be programmed to trigger the RST, HEALTHY, and FAULT outputs. APPLICATIONS INFORMATION (CONTINUED)

Summit Microelectronics, Inc 2070 1.0 7/16/03 14 The HEALTHY and FAULT outputs of the SMS66 are active as long as the triggering limit remains in a fault condition. The RST output also remains active as long as the triggering limit remains in a fault condition; however, once the trigger source goes away the RST will remain active for a reset timeout period (t PRTO). POWER-OFF SEQUENCING The SMS66 can be programmed to perform Power-off sequencing in either the same order or reverse order of Power-on sequencing. Power-off sequencing is the same as power-on sequencing and can be initiated by the PWR_ON/OFF pin, via I 2C control or triggered by a fault condition on any of the monitored inputs. Toggling the PWR_ON/OFF pin to its inactive state will initiate the Power-off sequence. To enable software control of the Power-off sequencing feature, the SMS66 offers an I 2C command to initiate Power-off sequencing regardless of the state of the PWR_ON/OFF pin. Furthermore, Power-off sequencing can be initiated by a fault condition on a monitored input. Once Power-off sequencing begins, the SMS66 will wait a Power-off delay time (t DPOFF) for any channel in the last sequence position (reverse order) and then deactivate the PUP outputs for those channels. The Power-off delay times are individually programmable for each channel. The SMS66 will then wait until all VM X inputs of the channels assigned to that sequence position are below their programmed OFF thresholds. At this point, the SMS66 will decrement to the next sequence position and begin to timeout the Power-off delay times for the associated channels. This process continues until all of channels in the sequence have turned off and are below their OFF thresholds. The status register reveals th at all sequenced channels have turned off. The Power-off sequencing mode ends when all sequenced supplies are below their OFF thresholds. The programmable sequence termination timer can be used to protect against a stalled Power-off sequence. This timer resets itself at the beginning of each sequence position. All channels in the sequence position must go below their OFF threshold before the sequence termination timer times out (t STT) or the sequence will terminate and all PUP outputs will be switched to their inactive state. This timer has four settings of OFF, 100ms, 200ms and 400ms. The sequence termination timer can be disabled separately for Power-off sequencing. While the SMS66 is in the Power-off sequencing mode the RST output is held active and the HEALTHY output is held inactive regardless of trigger sources. The Force Shutdown trigger option is also disabled while in this mode. Furthermore, the SMS66 will not respond to activity on the PWR_ON/OFF pin or to a Power-on I 2C command during Power-off sequencing mode. FORCE SHUTDOWN The Force Shutdown operation brings all PUP X outputs to their inactive state. This operation is used for an emergency shutdown when there is not enough time to sequence the supplies off. The Force Shutdown operation shuts off all sequenced channels and waits for the supply voltages to drop below their respective OFF thresholds. A Force Shutdown operation can be initiated by any one of four events. The first two methods for initiating a Force Shutdown are always enabled. Simply taking the FS pin to its active state will initiate a Force Shutdown operation and maintain it until the pin is brought to its inactive state. An I 2C Force Shutdown command allows the Force Shutdown operation to be initiated via software control. This I2C Force Shutdown command sets a volatile register bit that triggers a Force Shutdown. This bit is cleared after all sequenced channels have dropped below their OFF voltage threshold. During Power-on and Power-off sequencing, the sequence termination timer can initiate a Force Shutdown operation. As described in the previous sections, the sequence termination timer triggers a Force Shutdown operation if it times out before the power supply voltages surpass their voltage thresholds. This Force Shutdown will remain active until all sequenced power supply channels have dropped below their OFF voltage threshold. While the SMS66 is in monitor mode, a programmed fault condition on any power supply channel or on the 12VIN or VDD inputs can trigger a Force Shutdown. A Force Shutdown resulting from this will remain active until all sequenced power supply channels have dropped below their OFF voltage threshold. APPLICATIONS INFORMATION (CONTINUED)

Summit Microelectronics, Inc 2070 1.0 7/16/03 15 RESTART OF POWER-ON SEQUENCING Once a Force Shutdown or Power-off operation has completed, the SMS66 can restart the Power-on sequencing. The device can be programmed to automatically restart afte r a Force Shutdown provided the PWR_ON/OFF pin remains in the active state or the I2C Power-on command remains in the command register. If this option is not selected, the SMS66 requires toggling of the PWR_ON/OFF pin or toggling of the I 2C commands by issuing a Power-off command and then reissuing the Power-on command in order to restart Power-on sequencing. In either scenario, the FS pin will prevent the SMS66 from restarting Power- on sequencing. In addition, the device can be programmed to check that VDD and the 12VIN are within their programmed voltage thresholds before restarting Power-on sequencing. APPLICATIONS INFORMATION (CONTINUED)

Summit Microelectronics, Inc 2070 1.0 7/16/03 16 Figure 5 – SMS66 Applications schematic. APPLICATIONS INFORMATION (CONTINUED)

Summit Microelectronics, Inc 2070 1.0 7/16/03 17 The end user can obtain the Summit SMX3200 programming system for device prototype development. The SMX3200 system consists of a programming Dongle, cable and Windows TM GUI software. It can be ordered on the website or from a local representative. The latest revisions of all software and an application brief describing the SMX3200 is available from the website (www.summitmicro.com The SMX3200 programming Dongle/cable interfaces directly between a PC’s par allel port and the target application. The device is then configured on-screen via an intuitive graphical user interface employing drop-down menus. The Windows GUI software w ill generate the data and send it in I2C serial bus format so that it can be directly downloaded to the SMS66 via the programming Dongle and cable. An example of the connection interface is shown in Figure 6. When design prototyping is complete, the software can generate a HEX data file that should be transmitted to Summit for approval. Summit will then assign a unique customer ID to the HEX code and program production devices before the final electrical test operations. This w ill ensure proper device operation in the end application. Pin 9, 5V Pin 7, 10V Pin 5, Reserved Pin 3, GND Pin 1, GND Pin 6, MR# Pin 4, SDA Pin 2, SCL Pin 8, Reserved Pin 10, Reserved Top view of straight 0.1" x 0.1 closed-side connector. SMX3200 interface cable connector. SMS66 SDA SCL VDD_CAP GND 0.1 F Positive Supply Common Ground MR 1N4148 Figure 6– SMX3200 Programmer I2C serial bus connections to program the SMS66. Note that the MR pin does not need to be connected to pin 6 for programming purposes. DEVELOPMENT HARDWARE & SOFTWARE

Summit Microelectronics, Inc 2070 1.0 7/16/03 18 SERIAL INTERFACE Access to the configuration registers, general-purpose memory and command and status registers is carried out over an industry standar d 2-wire serial interface (I2C). SDA is a bi-directional data line and SCL is a clock input. Data is clocked in on the rising edge of SCL and clocked out on the falling edge of SCL. All data transfers begin with the MSB. During data transfers SDA must remain stable while SCL is high. Data is transferred in 8-bit packets with an intervening clock period in which an Acknowledge is provided by the device receiving data. The SCL high period (t HIGH) is used for generating Star t and Stop conditions that precede and end most transactions on the serial bus. A high-to-low transition of SDA while SCL is high is considered a Start condition while a low-to-high transition of SDA while SCL is high is considered a Stop condition. The interface protocol allows operation of multiple devices and types of devices on a single bus through unique device addressing. The address byte is comprised of a 4-bit device type identifier (slave address) and a 3-bit bus address. The remaining bit indicates either a read or a write operation. Refer to Table 1 for a description of the address bytes used by the SMS66. The device type identifier for the memory array is generally set to 1010 BIN following the industry standard for a typical nonvolatile memory. There is an option to change the identifier to 1011 BIN allowing it to be used on a bus that may be occupied by other memory devices. The configuration registers are grouped with the memory array and thus use 1010 BIN or 1011 BIN as the device type identifier. The command and status registers as well as the 10-bit ADC are accessible with the separate device type identifier of 1001BIN. The bus address bits A1 and A0 are programmed into the configuration registers. Bus address bit A[2] can be programmed as either 0 or biased by the A2 pin. The bus address accessed in the address byte of the serial data stream must match the setting in the SMS66 and on the A2 pin. Any access to the SMS66 on the I2C bus will temporarily halt the monitoring function. This is true not only during the monitor mode, but also during Power-on and Power-off sequencing when the device is monitoring the channels to determine if they have turned on or turned off. The SMS66 halts the monitor function from when it acknowledges the address byte until a valid stop is received. WRITE Writing to the memory or a configuration register is illustrated in Figures 8, 9, 11, 13 and 14. A Start condition followed by the address byte is provided by the host; the SMS66 responds with an Acknowledge; the host then responds by sending the memory address pointer or configur ation register address pointer; the SMS66 responds with an acknowledge; the host then clocks in on byte of data. For memory and configuration register writes, up to 15 additional bytes of data can be clocked in by the host to write to consecutive addresses within the same page. After the last byte is clocked in and the host receives an Acknowledge, a Stop condition must be issued to initiate the nonvolatile write operation. READ The address pointer for the configuration registers, memory, command and status registers and ADC registers must be set before data can be read from the SMS66. This is accomplished by a issuing a dummy write command, which is simply a write command that is not followed by a Stop condition. The dummy write command sets the address from which data is read. After the dummy write command is issued, a Start command followed by the address byte is sent from the host. The host then waits for an Acknowledge and then begins clocking data out of the slave device. The first byte read is data from the address pointer set during the dummy write command. Additional bytes can be clocked out of cons ecutive addresses with the host providing an Acknowledge after each byte. After the data is read from the de sired registers, the read operation is terminated by the host holding SDA high during the Acknowledge clock cycle and then issuing a Stop condition. Refer to Figures 10, 12 and 15 for an illustration of the read sequence. WRITE PROTECTION The SMS66 powers up into a write protected mode. Writing a code to the volatile write protection register can disable the write protection. The write protection register is located at address 87 HEX of slave address 1001BIN. Writing 0101 BIN to bits [7:4] of the write protection register allow writes to the general-purpose memory while writing 0101 BIN to bits [3:0] allow writes to the configuration registers. The write protection can re- I2C PROGRAMMING INFORMATION

Summit Microelectronics, Inc 2070 1.0 7/16/03 19 enable by writing other codes (not 0101BIN) to the write protection register. Writing to the write protection register is shown in Figure 7. CONFIGURATION REGISTERS The majority of the configuration registers are grouped with the general-purpose memory located at either slave address 1010 BIN or 1011 BIN. The bus address bits, A[1:0], used to differentiate the general-purpose memory from the configuration registers are set to 11BIN. Bus address bit A[2] can be programmed as either 0 or biased by the A2 pin. Two additional configuration registers are located at addresses 83HEX and 84HEX of slave address 1001BIN. Writing and reading the configuration registers is shown in Figures 8, 9, 10,11 and 12. GENERAL-PURPOSE MEMORY The 4k-bit general-purpose memory is located at either slave address 1010 BIN or 1011 BIN. The bus address bits, A[1:0], used to differentiate the general- purpose memory from the configuration registers are set to 00BIN for the first 2k-bits and 01BIN for the second 2k-bits. Bus address bit A[2] can be programmed as either 0 or biased by the A2 pin. The word address must be set each time the memory is accessed. Memory writes and reads are shown in Figures 13, 14 and 15. COMMAND AND STATUS REGISTERS The command and status registers are located at slave address 1001 BIN. Writes and reads of the command and status registers are shown in Figures 16 and 17. ADC CONVERSIONS An ADC conversion on any monitored channel can be performed and read over the I 2C bus using the ADC read command. The ADC read command, shown in Figure 18, starts with a dummy write to the 1001 BIN slave address. Bits [6:3] of the word address byte are used to address the desired monitored input. Once the device acknowledges the channel address, it begins the ADC conversion of the addressed input. This conversion requires 70 µs to complete. During this conversion time, acknowledge polling can be used. The SMS66 will not acknowledge the address bytes until the conversion is complete. When the conversion has completed, the SMS66 will acknowledge the address byte and return the 10-bit conversion along with the 4-bit channel address echo. GRAPHICAL USER INTERFACE (GUI) Device configuration ut ilizing the Windows based SMS66 graphical user interface (GUI) is highly recommended. The software is available from the Summit website ( www.summitmicro.com ). Using the GUI in conjunction with this datasheet and Application Note 33, simplifies the proc ess of device prototyping and the interaction of the various functional blocks. A programming Dongle (SMX3200) is available from Summit to communicate with the SMS66. The Dongle connects directly to the parallel port of a PC and programs the device through a cable using the I 2C bus protocol. Slave Address Bus A ddress Register Type 1001BIN A2 A1 A0 Write Protection Register, Command and Status Registers, Two Configuration Registers, ADC Conversion Readout A2 0 0 1 st 2-k Bits of General-Purpose Memory A2 0 1 2 nd 2-k Bits of General-Purpose Memory 1010BIN or 1011BIN A2 1 1 Configuration Registers Table 1 - Address bytes used by the SMS66.

Summit Microelectronics, Inc 2070 1.0 7/16/03 24 DEFAULT CONFIGURATION REGISTER SETTINGS – SMS66-171 Register Contents Register Contents Register Contents Register Contents R0C 00 R4B 7F RA4 29 RC A 0C R0D 00 R4C 00 RA5 5D RCB 00 R0E 03 R80 42 RA6 11 RCC 0F R0F A1 R81 48 RA7 71 RCD FF R10 8F R82 82 RA8 40 RCE 0F R11 9F R83 3E RA9 CE RCF FF R12 AF R84 2 A RAA 80 RD0 0C R13 BF R85 B8 RAB 8F RD1 00 R14 CF R86 12 RAC 29 RD2 0C R15 DF R87 F6 RAD 1F RD3 00 R18 00 R88 41 RAE 11 RD4 0F R19 00 R89 C8 RAF 33 RD5 D8 R30 0D R8 A 81 RB0 2 A RD6 0F R31 60 R8B B9 RB1 67 RD7 D8 R32 0D R8C 2 A RB2 0 A RE0 00 R33 DC R8D 34 RB3 52 RE1 3D R34 0E R8E 12 RB4 03 RE2 00 R35 45 R8F 49 RB5 FF RE3 3D R36 0E R90 49 RB6 03 RE4 00 R37 A2 R91 5C RB7 FF RE5 3D R38 0F R92 81 RB8 0D RE6 00 R39 08 R93 52 RB9 9 A RE7 3D R3A 0F R94 29 RB A 0D RE8 00 R3B D6 R95 D7 RBB 56 RE9 3D R3C 00 R96 11 RBC 0F RE A 00 R3D 12 R97 EB RBD E0 REB 3D R3E 48 R98 41 RBE 0F R83 05 R40 0D R99 3E RBF E0 R84 00 R41 B9 R9 A 81 RC0 0B R42 0E R9B 33 RC1 38 R43 39 R9C 29 RC2 0B R44 0E R9D 9 A RC3 38 R45 A4 R9E 11 RC4 09 R46 0F R9F AER C 59 0 R47 16 RA0 41 RC6 09 R48 0F RA1 0B RC7 90 R49 B4 RA2 80 RC8 0C R4A 06 RA3 F6 RC9 00 RC1 The default device ordering number is SMS66F-171, is programmed as described above and tested over the commercial temperature range. Application Note 42 contains a complete description of the Windows GUI and the default settings of each of the 142 individual Configuration Registers.

Summit Microelectronics, Inc 2070 1.0 7/16/03 25 PACKAGE A B Pin 1 Indicator Inches (Millimeters) 0.002 - 0.006 (0.05-0.15) MAX.0.047 (1.2) 0.037 - 0.041 0.95 - 1.05 0.018 - 0.030 (0.45 - 0.75) 0.039 (1.00) 0.02 (0.5) BSC 0.007 - 0.011 (0.17 - 0.27) DETAIL "A" DETAIL "B" (B) (A) (A) 0.354 (9.00) BSC 0.276 (7.00) BSC (B)

48 PIN TQFP PACKAGE

Summit Microelectronics, Inc 2070 1.0 7/16/03 26 PART MARKING SUMMIT SMS66F AYYWW Pin 1 Annn Summit Part Number Date Code (YYWW) Part Number suffix (Contains Customer specific ordering requirements) Lot tracking code (Summit use) Drawing not to scale xx Status Tracking Code (Blank, MS, ES, 01, 02,...) (Summit Use) Product Tracking Code (Summit use)

ORDERING INFORMATION

NOTE 1 - This is a Preliminary Information data sheet that describes a Summit product currently in pre-production with limited characterization. SUMMIT Microelectronics, Inc. reserves the ri ght to make changes to the products cont ained in this publication in order to impr ove design, performance or reliability. SUMMIT Microelectronics, Inc. assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and sche dules contained herein reflect representative operating parameters, and may vary depending upon a user’s specific application. While the inform ation in this publication has been carefully checked, SUMMI T Microelectronics, Inc. shall not be liabl e for any damages arising as a result o f any error or omission. SUMMIT Microelectronics, Inc. does not recommend the use of any of its products in life support or aviation applications where the failure or malfunction of the product can reasonably be expe cted to cause any failure of either syst em or to significantly affect their sa fety or effectiveness. Products are not authorized for use in such applications unless SU MMIT Microelectronics, Inc. receives written assurances, to its satisfaction, that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; and (c) potential liability of SUMMIT Microelectronics, Inc. is adequately protected under the circumstances. Revision 1.0 - This document supersedes all previous versions. Please check the Su mmit Microelectronics Inc. web site at www.summitmicro.com for data sheet updates. © Copyright 2003 SUMMIT MICROELECTRONICS, Inc. Power Management for Communications™ I2C is a trademark of Philips Corporation. SMS66 F nnn Package F=48 Lead TQFP Part Number Suffix (see page 24) Summit Part Number Specific requirements are contained in the suffix such as Commercial or Industrial Temp Range, Hex code, Hex code revision, etc.