Technical Information Sheet www.novaris.com.au

72 Browns Road, Kingston Tasmania 7050 Australia

Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au SLT - Threaded Signal Line Protectors SLT (0050-D15V1) SCN SLT1-... SCN SIG SLT3-... SCN L1+ L1- L2- L2+ SLT4-... SCN N L L2- L2+ SLT4-36-275 24 24 53 53 M20 x 1.5 Thread Size 1/2” NPT Thread Size Field Instrument Surge Protectors Novaris threaded instrument protectors provide surge protection for most twisted pair signalling schemes and are designed to be installed directly at the field equipment providing protection against induced surges and transients. M20 and 1/2” NPT threads The threaded enclosure provides an easy installation by directly screwing into a free cable entry on the instrument. Common thread types such as M20 x 1.5 and ½” NPT threads are accommodated for. Other threads are available by request. Multistage design The multistage design provides a high energy gas discharge tube (GDT) as primary protection for common mode disturbances, commonly associated with lightning strikes and power system earth faults and a secondary metal-oxide varistor clamping stage across the signal lines. This combination provides very robust surge protection with high transient suppression and low let-through voltages. In addition protection is provided for cable screens which may be open circuit at the instrument. SLT-Y Adapter Where a field instrument has no free cable entry Novaris can supply a Y-piece adapter to accommodate the threaded instrument protector and cable gland. The SLT-Y is available in the same thread types as the SLT protectors. Model Signal Type Thread Size Hazardous Area Product M20 x 1.5 1/2 ” NPT SLTx-7v5 0 - 5 VDC analogue 5 V digital -M20 -N12 IS-SLTx-7v5 SLTx-18 0 - 12 VDC analogue 12 V digital -M20 -N12 IS-SLTx-18 SLTx-36 0 - 24 VDC analogue 4-20 mA -M20 -N12 IS-SLTx-36 SLTx-68 0 - 48 VDC analogue 48 V digital -M20 -N12 – SLT4-RTD RTD applications Thermocouple -M20 -N12 IS-SLT4-RTD SLT4-36-275 4-20 mA & Power supply -M20 on request –

www.novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Novaris has a policy of continuing product development, therefore specifications are subject to change without notice. Copyright: © 2016 Novaris Pty Ltd Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Model SLTx-7v5 SLTx-18 SLTx-36 SLTx-68 SLT4-RTD SLT4-36-275 Electrical Specifications Connection Type Shunt Shunt Shunt Shunt Shunt Shunt Number of lines x = 1 → 1 pair x = 3 → 3 lines x = 4 → 4 lines 4 lines 1 pair Signal (S)

1 L & N Power (P)

Modes of protection Transverse and common mode Maximum continuous voltage (DC) Uc 7 V 18 V 36 V 65 V 8 V 36 V (S) / 350 V (P) Maximum continuous voltage (AC) Uc 5 V 14 V 30 V 50 V 6 V 30 V (S) / 275 V (P) Maximum discharge current (8/20 µs) Imax 5 kA per line (10 kA common mode) Maximum discharge current (10/350 µs) Iimp 1.25 kA per line (2.5 kA common mode) Impulse durability C2 10 x 2.0 kA 8/20 µs D1 2 x 0.5 kA 10/350 µs C2 10 x 0.5 kA 8/20 µs Maximum load current IL – L-L Voltage protection level @ 1 kV/ µs Up 45 V 50 V 75 V 100 V 45 V 75 V (S) / – (P) L-L Voltage protection level @ 1 kA 8/20 µs Up 70 V 75 V 110 V 160 V 70 V – (S) / – (P) L-L Voltage protection level @ 100 V/ s 25 V 30 V 60 V 80 V 25 V 55 V (S) / – (P) L-PE Voltage protection level @ 1 kV/ µs Up 350 V 350 V 350 V 350 V 350 V 350 V (S) / 900 V (P) L-PE Voltage protection level @ 2 kA 8/20 µs Up 530 V 530 V 530 V 530 V 530 V – (S) / – (P) L-PE Voltage protection level @ 100 V/ s 230 V 230 V 230 V 230 V 230 V 230 V (S) / 600 V (P) AC durability 1 A rms, 5 x 1 s 1 A rms, 5 x 1 s 1 A rms, 5 x 1 s 1 A rms, 5 x 1 s 1 A rms, 5 x 1 s 1 A rms, 5 x 1 s Overstressed fault mode Mode 1 (SLT disconnected, line still operable) Response time tA < 5 ns Line resistance – Line inductance – L-L capacitance 20 nF 10 nF 7 nF 1 nF 20 nF 7 nF (S) / 60 pF (P) L-PE capacitance < 1 pF Insertion loss @ 150 Ω – 3 dB Frequency @ 150 Ω fc 100 kHz Mechanical Specifications Operating temperature -40 to +85 ºC Humidity Range 5 to 95% Connection type / capacity 250 mm, 0.75 mm2 flying leads Terminal screw torque – Environmental IP 67 installed Dimensional Drawing Given by thread size Mounting Thread options M20 x 1.5 or 1/2 “ NTP Earthing via lead; 90 V isolation between earth and shield Enclosure / Colour Stainless steel Standards IEC 61643-21:2012 SPD connected to telecommunications and signalling networks - Cat C2, D1 AS/NZS 1768:2007 Signalling/Telecommunications surge protection UL 1449 3rd edition & UL 497B Protectors for data communications and fire-alarm circuits ITU-T K.44: 2012 Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents Shipping Weight 165 g 165 g 165 g 165 g 165 g 165 g Customs Tariff 85363000 85363000 85363000 85363000 85363000 85363000