SFD1 NOVARIS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Ordering Information
Technical Information Sheet www.novaris.com.au
72 Browns Road, Kingston Tasmania 7050 Australia
Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au SFD1 - Single Phase Surge Filters SFD1 (0024-D11V5 N PEL N PEL line load N PEL N PEL line load SFD1-x-10-275 SFD1-... 49 115 AA B, C & D 54 72 108 DCB Low exposure Medium exposure Options Single Phase Three Phase Single Phase Three Phase SFD Version SPDT alarm contact Polycarbonate enlosure Max Load Current 6A SFD1-6-10-275 SFD3-10-50-275-A SFD1-20-100-275 SFM-Series SFD1-6-10-275 – -P
10 A SFD1-10-50-275 SFD3-10-50-275-A SFD1-20-100-275 SFM-Series SFD1-10-50-275 -A -P
20 A SFD1-20-50-275 SFD3-20-50-275-A SFD1-20-100-275 SFM-Series SFD1-20-50-275 -A -P
32 A SFD1-32-50-275 SFD3-32-50-275-A SFD1-32-100-275 SFM-Series SFD1-32-50-275 -A -P
Novaris DIN mount Surge Filter are suitable for installation in circuits up to 32A. The SFD range has been engineered to protect sensitive loads. Compact design Their compact design makes them an ideal choice for space restricted applications. All Mode Protection Protection is provided for all combinations of lines (L-N, L-PE, N-PE) ensuring the maximum level of protection is achieved at all times. Safe Metal Enclosure Novaris surge protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Three stages of protection Novaris surge filters have 2 stages of varistor protection separated by a low pass LC filter. This 3 stage combination reduces the effects of high frequency noise and transients to provide the highest level of protection to sensitive loads.
www.novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Novaris has a policy of continuing product development, therefore specifications are subject to change without notice. Copyright: © 2016 Novaris Pty Ltd Model SFD1-6-10-275 SFD1-10-50-275 SFD1-20-50-275 SFD1-20-100-275 SFD1-32-50-275 SFD1-32-100-275 Electrical Specifications Connection type Series Series Series Series Series Series Modes of protection L-N, L-PE, N-PE L-N, L-PE, N-PE L-N, L-PE, N-PE L-N, L-PE, N-PE L-N, L-PE, N-PE L-N, L-PE, N-PE Phases 1 1 1 1 1 1 Nominal voltage Uo 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC Short circuit withstand level ISCCR 10 kA 25 kA 25 kA 25 kA 25 kA 25 kA Maximum backup fuse (gL/gG) 6 A 10 A 20 A 20 A 32 A 32 A L-N Maximum continuous voltage U C 275 VAC 275 VAC 275 VAC 275 VAC 275 VAC 275 VAC Maximum load current IL 6 A 10 A 20 A 20 A 32 A 32 A Maximum voltage Drop (% of Uo) ∆U < 1% < 1% < 1% < 1% < 1% < 1% 3 dB Frequency at 50 Ω 9.4 kHz 2600 Hz 800 Hz 800 Hz 380 Hz 380 Hz Maximum discharge current (8/20 µs) Imax 10 kA 50 kA 50 kA 100 kA 50 kA 100 kA Lightning impulse current (10/350 µs) Iimp – 3 kA 3 kA 6.25 kA 3 kA 6.25 kA Nominal discharge current (8/20 µs) In 4 kA 20 kA 20 kA 40 kA 20 kA 40 kA Voltage protection level @ 3 kA 8/20 µs Up < 700 V < 600 V < 600 V < 600 V < 600 V < 600 V Voltage protection level @ In Up < 900 V < 1000V < 1000V < 1100 V < 1000V < 1100V Load side surge withstand (nominal) 6 kA 10 kA 10 kA 10 kA 10 kA 10 kA Response time tA Instantaneous Instantaneous Instantaneous Instantaneous Instantaneous Instantaneous Temporary overvoltage (TOV) UT 440V / 5 sec N-PE Maximum continuous voltage UC 275 VAC 255 VAC 255 VAC 255 VAC 255 VAC 255 VAC Maximum discharge current (8/20 µs) Imax 10 kA 25 kA 60 kA 60 kA 60 kA 60 kA Lightning impulse current (10/350 µs) Iimp – 2 kA 15 kA 15 kA 15 kA 15 kA Nominal discharge current (8/20 µs) In 4 kA 10 kA 50 kA 50 kA 50 kA 50 kA Voltage protection level @ 1 kV/ µs Up < 500V < 700 V < 700 V < 700 V < 700 V < 700 V Voltage protection level @ In Up < 900 V < 1000 V < 1300 V < 1300 V < 1300 V < 1300 V Response time tA Instantaneous < 100 ns < 100 ns < 100 ns < 100 ns < 100 ns Follow current interrupt rating Ifi – 20 A 100 A 100 A 100 A 100 A Earth leakage current < 500 µA < 10 µA < 10 µA < 10 µA < 10 µA < 10 µA Indication Display LED status External alarm – Optional Display / Alarm function – segment / thermal failure, SPDT voltage free contact Alarm isolation – 4 kV Mechanical Specifications Operating temperature -40 to +70 ºC Humidity Range 5 to 95% non–condensing Terminal capacity – power 0.5 – 2.5 mm 2 2.5 – 16 mm2 Terminal capacity – alarms – 0.5 – 2.5 mm2 Terminal screw torque – power 0.5 Nm 2.0 Nm Terminal screw torque – alarm – 0.5 Nm Environmental / Location IP 20 / Indoor Dimensional Drawing A B / C with alarm C C D D Device width 18 mm 54 mm 72 mm 72 mm 108 mm 108 mm Mounting TS35 DIN rail / Panel mount Enclosure / Colour Metal / Black Standards IEC 61643-11:2011 SPD connected to low-voltage power systems - Type 2+3 AS/NZS 1768:2007 A.C. power system SPD - Cat C1, B, A UL 1449 3 rd edition Low voltage SPD - Type 3 (< 10 m from device) IEEE 62.41.2:2002 Low voltage SPD - Cat C (< 10 m from device) Shipping Weight 350 g 440 g 605 g 625 g 730 g 750 g Customs Tariff 85354010 85354010 85354010 85354010 85354010 85354010