PROCESS CONTROL PROTECTION SLM Multiline Protectors Novaris SLM offers protection for up to 12 signal lines. Typical applications include process control, telemetry, PLC, and irrigation systems. SLM-7v5 SLM-18 SLM-36 SLM-68 SLM-200 Electrical Specifications Connection type Series Modes of protection Transverse and common mode Number of lines 12 Maximum continuous voltage (DC) Uc 7V 16V 34V 65V 200V Maximum continuous voltage (AC) Uc 5V 11V 24V 46V 140V Discharge current 8/20µs Imax 20kA Protection stages Multistage Maximum load current IL 350mA (2A for option 2; 500mA for option H) Impulse voltage 10/700µs Up 8V 19V 40V 76V 235V Line resistance - base 8.2W Line resistance - 2A 0.1W Line resistance - high frequency 3.9W Maximum frequency fc 250kHz (25MHz high frequency option) Mechanical Specifications Operating temperature / humidity -40 to +85ºC / 5 to 95% non-condensing Terminal capacity 2.5mm Terminal screw torque 0.5Nm Environmental IP 20 Mounting Panel mount Weight 250g Dimensions Width 128mm Height 80mm Depth 42mm Options [*] Maximum load current 2A I L 2 High frequency 25MHz fc H Standards Compliance IEC61643-21 ITU-T K.44 AS/NZS 1768 IEEE C62.41 UL497B SLM - 7v5 - [*] Product Series Options Uc