SLD NOVARIS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Ordering Information
Technical Information Sheet www.novaris.com.au
72 Browns Road, Kingston Tasmania 7050 Australia
Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au SLD - Signal Line Protectors SLD (0064-D1V2) L1 SCN / L2 L1 L2 SCN / L3 L4 L1 L2 L3 L4 E1 E2 E3 E4 L5 L6 L7 L8 E1 E2 E3 E4 E5 E6 E7 E8E1 SCN / E2 SLD1-..line load SLD2-..line load SLD4-..line load SCN / SCN SCN 492919.5 115 SLD4SLD2SLD1 Signal Type Options Indirect Earthing Max. load current: IL= 2 A High frequency: fc= 10 MHz SLDx-7v5 5 V digital 0 - 6 V analog -EC90 -2 -H SLDx-18 12 V digital 0 - 12 V analog -EC90 -2 -H SLDx-36 24 V digital 0 / 4 - 20 mA -EC90 -2 -H SLDx-68 48 V digital – -EC90 -2 -H SLDx-485 RS 485 RS422 Standard -2 – SLDx-DH RS232 Data Highway Standard -2 – SLDx-PSTN Public Switched Telephone Network -EC90 – – High Surge Current Signal Line Protectors SLD Signal Line Protectors are designed to protect the most sensitive electronic equipment in lightning intense environments. So they are ideal for the protection of PLC’s, fire and security systems, railway signalling and SCADA equipment. Multistage Transient Protection Models featuring multistage transient protection deliver greater levels of protection through a staged approach. The primary stage absorbs the majority of the surge energy. The remaining stages provide accurate clamping and a degree of redundancy. Surge Current Fusing Surge current fuses allow components to absorb maximum energy but in the event of a component failure the fuse will open to isolate the damaged component. Safe Metal Enclosure Novaris surge protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.
www.novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Novaris has a policy of continuing product development, therefore specifications are subject to change without notice. Copyright: © 2016 Novaris Pty Ltd Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Model SLDx-7v5 SLDx-18 SLDx-36 SLDx-68 SLDx-485 SLDx-DH SLDx-PSTN Electrical Specifications Connection Type Series Series Series Series Series Series Series Number of lines x = 1 → 1 pair x = 2 → 2 pairs x = 4 → 4 pairs Modes of protection Transverse and common mode Maximum continuous voltage (DC) Uc 7 V 16 V 34 V 65 V 8 V 34 V 200 V Maximum continuous voltage (AC) Uc 5 V 11 V 24 V 46 V 6 V 24 V – Maximum discharge current (8/20 µs) Imax 10 kA per line (20 kA common mode) Maximum discharge current (10/350 µs) Iimp 1.25 kA per line (2.5 kA common mode) Impulse durability C2 10 x 10 kA 8/20 µs D1 2 x 2.5 kA 10/350 µs Maximum load current IL 250 mA 250 mA 250 mA 250 mA 500 mA 500 mA 250 mA L-L Voltage protection level @ 1 kV/ µs Up 10 V 20 V 39 V 70 V 19 V 47 V 370 V L-L Voltage protection level @ 3 kA 8/20 µs Up 11 V 21 V 40 V 72 V 14 V 47 V L-L Voltage protection level @ 100 V/ s 8 V 18 V 36 V 68 V 10 V 38 V 360 V L-PE Voltage protection level @ 1 kV/ µs Up 10 V 20 V 39 V 70 V 19 V 47 V 370 V L-PE Voltage protection level @ 3 kA 8/20 µs Up 11 V 21 V 40 V 72 V 14 V 47 V L-PE Voltage protection level @ 100 V/ s 8 V 18 V 36 V 68 V 10 V 38 V 360 V AC durability 5 x 1 s, 1 Arms 5 x 1 s, 1 Arms 5 x 1 s, 1 Arms 5 x 1 s, 1 Arms 5 x 1 s, 1 Arms 5 x 1 s, 1 Arms 5 x 1 s, 1 Arms Overstressed fault mode Mode 3 (open circuit) Response time tA < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns Line inductance 33 µH 33 µH 33 µH 33 µH < 1 µH < 1 µH < 1 µH L-L capacitance 11 nF 6 nF 5 nF 4 nF 19 pF 18 pF 148 pF L-PE capacitance 11 nF 6 nF 5 nF 4 nF 25 pF 25 pF 158 pF Insertion loss @ 150 Ω < 0.5 dB (< 70 kHz) < 0.5 dB (< 120 kHz) < 0.5 dB (< 150 kHz) < 0.5 dB (< 150 kHz) < 0.5 dB (< 50 MHz) < 0.5 dB (< 50 MHz) < 0.5 dB (< 5 MHz) 3 dB Frequency @ 150 Ω fc < 260 kHz < 360 kHz 450 kHz 460 kHz 100 MHz 100 MHz 20 MHz Mechanical Specifications Operating temperature -40 to +85 ºC Humidity Range 5 to 95% non-condensing Connection type / capacity 2.5 mm2 via pluggable connectors Terminal screw torque 0.5 Nm Environmental IP 20/ Indoor Dimensional Drawing see Dimensions Mounting TS35 DIN rail Earthing - Direct earth connection via DIN rail and screw terminals standard - 90 V isolation between DIN rail earth and shield with -EC90 option Enclosure / Colour Metal / black Standards IEC 61643-21:2012 SPD connected to telecommunications and signalling networks - Cat C2, D1 AS/NZS 1768:2007 Signalling/Telecommunications surge protection UL 1449 3rd edition & UL 497B Protectors for data communications and fire-alarm circuits ITU-T K.44: 2012 Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents AS/CA S008:2010 Requirements for Customer Cabling Products AS/NZS 4117:1999 Surge Protective Devices for Telecommunications Applications Shipping Weight x = 1 → 250 g x = 2 → 300 g x = 4 → 400 g Customs Tariff 85363000 85363000 85363000 85363000 85363000 85363000 85363000