SLA SANYOU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

Miniature relay with high switching capability:30 .A Contact : , 1 .form Form A Form B or Form C Special 4000type of VAC dielectric strength 6000and V surge voltage (1.2/50 S between) coil and contact ( , , DJ DMJ DBJu not include )Open type available. Sealed type and open type available. Patent Number ZL 2008 20050972.1 SANYOU RELAYS Relays for advanced technology Miniature High Power Relay SLA-DM Standard type S Mark/ Coil Power H&S 20 250A VAC 20A 250VAC 5,000VA Mark H S AC V Hz min& : 2,000 , 50/60 1 . version V: 3.4 Coil Data at(2 0 ℃ ) AC V Hz min open type available1,500 ,50/60 1 . ( ) Satisfy IEC product is available60335-1 . Satisfy IEC product is available60079-15 .

Form A: 30 240A VAC Making A VAC ms: 80 250 (300 ) Breaking A VAC:20 250 Form B: 15 240A VAC Form C: 20 /10 240A A VAC Form A: 30 240 , /A VAC Resistive General Use 15 240A VAC 1-1/2 240 3/4 120HP VAC HP VAC; TV VAC-8 120 30 120 , /A VAC Resistive General Use Pilot duty VA VAC: 470 , 240 Electronic Ballast A VAC VAC: 10 277 /120 Form B: 30 120 ,A VAC General Use 20 240 ,A VAC General Use 20 120 ,A VAC Resistive 10 240 , /A VAC Resistive General Use Pilot duty VA VAC: 275 , 240 Electronic Ballast A VAC VAC: 5 , 277 /120 1/2 240 1/4 120HP VAC HP VAC; Form C: .. ..NO NC 30 240/120 ,A VAC Resistive 30 240/120 , 20 240/120 ,A VAC General Use A VAC Resistive 20 240 , 20 240/120 ,A VAC Resistive A VAC General Use 10 240 , 10 240 ,A VAC Resistive A VAC Resistive 1-1/2 240 1/2 240HP VAC HP VAC 3/4 125/120 1/4 125/120HP VAC HP VAC TV VAC TV VAC-8 120 -3 120 20 240 , 10 240 ,A VAC General Use A VAC General Use Pilot Duty VA VAC Pilot Duty VA VAC: 470 240 : 275 240 Electronic Ballast Electronic Ballast:: 10 277 /120 5 277 /120A VAC VAC A VAC VAC SLA 183.33 91.67 45.83 22.92 266.67 133.33 66.67 33.33 1.1W 131 524 2095 1.6W 22.5 360 1440 Coil Data of H mark (2 0 ℃ )at Nominal voltage ()VDC Coil resistance 10% ( Ω) Max. allowable voltage Drop out- voltage (. )Min Nominal operating current 10% ( )mA Pick up- voltage (. )Max Nominal operating power 75 % of nominal voltage 5%o f nominal voltage 5% of nominal voltage 75% of nominal voltage 130 % of nominal voltage 130 % of nominal voltage Coil Data of S mark (2 0 ℃ )at Nominal operating power Drop out- voltage (. )Min Pick up- voltage (. )Max Max. allowable voltage Coil resistance 10% ( Ω) Nominal operating current 10% ( )mA Nominal voltage ()VDC Safety Approval Ratings (: , )Note More detail of approval ratings please refer to the safety certification CQC TUV UL CUL/ VDE 40036707E190598CQC02001002109 R50143450 Approval File No. Approved ratings Form A: 30 250A VAC Form B: 15 250A VAC Form C: 20 /10 250A A VAC Nomenclature

Ordering Information

Protective Construction Nil Open type S Flux proofed:- , - , M1 FJ Insulation System Nil Standard B Class B F Class F:- , - , - Contact Material Nil AgSnO AgCdO:- , 1 - 2 Terminal Type Nil Standard J Without terminal:- , - 6 # Contact Form Nil Form C B Form B M Form A:- , - ,- Coil Voltage VDC( ):05, 06, 09, 12, 15, 18, 24, 48, 110 Number of Poles Pole:1-1 -SH Sealed type washable Type Designation SLA: SLA -1 D J -F 30 250 ,A VAC NO 20 250 , ( )A VAC CO test NO 10 250 , ( )A VAC CO test NC Special Parameter Nil Standard type:- , Letter or number Special resquirement- -XX (2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different. (3) For sealed type testing, please open the ventilation hole of case before test. If more details are required, please contact us. (1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.

Car Heater and ventilation equipment Air conditioner Home appliances SLA P C B Layout bottom view... ( ) 6# terminal 6# terminal 6# terminal Wiring Diagram bottom view() Unless otherwise specified: If dimension mm tolerance mm<1 , : 0.2 ; If dimension mm tolerance mm1~5 , : 0.3 ; If dimension mm tolerance mm>5 , : 0.4 . Note Extended terminal dimension is dimension:1 . .before soldering Outline Dimensions Wiring Diagram P C,, . .( : ) unit mmBoard Layout Sealed type Open type 6# terminal 6# terminal 6# terminal 17.8 10.2 8.9 7.62 15.242.54 4- 2.1Φ 2- 1.1Φ 2.54 17.8 10.2 8.9 10.16 15.242.54 3- 2.1Φ 2- 1.1Φ 17.8 10.2 8.9 15.24 2.54 3- 2.1Φ 2- 1.1Φ 2.54 23.6 5.6( )/3.3normal type 14.9 2.77 bottom view

K .( ) 100110 100 80 90 100 110 120 130 140 150 160 30A 25A 20A 15A Characteristic Curves Percentage of Nominal Coil Voltage Contact Current A() Contact Voltage V() Max Switching Power. Contact Current A() Operations Ops ( 10000 .) Endurance CurveCoil Temp Rise. Note If you choose the sealed type before using please remove the convex platform at the top of the case to ensure the:, , .normal performance of the relay after the completion of a PCB operations they are as shown in the following diagram: with convex platform convex platform without convex platform 01 0 2 0 3 0 4 0 1( )cN O1b1( )cN C 100 10 100 200 1000 1( )cN O 1( )cN C AC/UNI8d1f/UNI8f7d ,Sanyou Corporation Limited All rights of Sanyou to reserved Disclaimer: This datasheet is the customers' reference. All the specification are subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application.Thus the user should in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning, However it is the user's responsibility to determine which product should be used only. please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.