Ordering Information

Technical Information Sheet www.novaris.com.au

72 Browns Road, Kingston Tasmania 7050 Australia

Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au SL - Slimline Signal Line Protectors SL (0004-D2V2) SL-xxx, SL420 SL module SCN SCN SL module SCN SCN -G base-EC90 base 68 mm 102 mm 7.5 mm A Model Signal Type Base Option Hazardous Area Product direct earthing indirect earthing SL7v5, SL18, SL 36, SL68 5 V, 12 V, 24 V, 48 V digital / analogue -G -EC90 IS- SL7v5, IS-SL18, IS- SL36 SL-36 RS232 Data Highway -G -EC90 IS-SL-DH SL485 RS 485 RS422 – -EC90 IS-SL485 SL-RTD RTD Applications Thermocouple -G -EC90 IS-SL-RTD SL420 1) 0 - 20 mA 4 - 20 mA -G -EC90 IS-SL420i SL-PSTN PABX PSTN -G -EC90 IS-SL-PSTN Process Control Protection Novaris SL range provides surge protection for most twisted pair signalling schemes. Ideal for the protection of PLCs, fire and security systems, telecommunications and telemetry systems, railway signalling, SCADA and other industrial monitoring and control equipment. Multistage failsafe design A high energy gas discharge tube (GDT) as primary protection plus series impedance and secondary components provide very robust surge protection with high transient suppression offering low let-through voltages. Two different earthing options With two different base options the SL protectors offer either direct earthing via DIN rail, for the most effective, low impedance earth connection (-G base) or a connection via GDT to the DIN rail, offering isolation under normal conditions and equipotential bonding during a surge (-EC90 base). Slimline pluggable modules The plug-in design provides simple and rapid replacement and testing - no rewiring needed. This also provides a convenient method of field equipment isolation if required. 1) LED indicates status of instrument loop

www.novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Novaris has a policy of continuing product development, therefore specifications are subject to change without notice. Copyright: © 2017 Novaris Pty Ltd Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Phone +61 3 6229 7233 Fax +61 3 6229 9245 E-mail sales@novaris.com.au Model SL7v5 SL18 SL36 SL68 SL-PSTN SL-485 SL-RTD SL-420 Electrical Specifications Connection Type Series Series Series Series Series Series Series Series Number of lines 1 pair 1 pair 1 pair 1 pair 1 pair 1 pair 1 pair 1 pair Modes of protection Transverse and common mode Maximum continuous voltage (DC) Uc 7 V 16 V 34 V 65 V 180 V 8 V 3 V 34 V Maximum continuous voltage (AC) Uc 5 V 11 V 24 V 46 V 130 V 6 V 2 V – Maximum discharge current (8/20 µs) Imax 5 kA per line (10 kA common mode) Maximum discharge current (10/350 µs) Iimp 1.25 kA per line (2.5 kA common mode) Impulse durability C2 10 x 5 kA 8/20 µs D1 2 x 2.5 kA 10/350 µs Maximum load current IL 250 mA 250 mA 250 mA 250 mA 250 mA 250 mA 250 mA 30 mA L-L Voltage protection level @ 1 kV/ µs Up 15 V 30 V 45 V 80 V 220 V 35 V 15 V 40 V L-L Voltage protection level @ 3 kA 8/20 µs Up 15 V 30 V 45 V 80 V 220 V 35 V 15 V 40 V L-L Voltage protection level @ 100 V/ s 9 V 20 V 38 V 72 V 210 V 15 V 4 V 36 V L-PE Voltage protection level @ 1 kV/ µs Up 350 V 350 V 350 V 350 V 350 V 350 V 350 V 350 V L-PE Voltage protection level @ 3 kA 8/20 µs Up 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V L-PE Voltage protection level @ 100 V/ s 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V AC durability 5 x 1 s, 1 Arms Overstressed fault mode Mode 3 (open circuit) Response time tA < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns < 5 ns L-L capacitance 18 pF 18 pF 18 pF 18 pF 18 pF 18 pF 18 pF 18 pF Insertion loss @ 150 Ω < 0.5 dB (< 1 MHz) 3 dB Frequency @ 150 Ω fc 60 MHz 60 MHz 60 MHz 60 MHz 60 MHz 70 MHz 70 MHz 60 MHz Mechanical Specifications Operating temperature -55 to +70 ºC Humidity Range 5 to 95% non–condensing Connection type / capacity 0.25 – 2.5 mm

2 Screw Cage Terminal

Terminal screw torque 0.5 Nm Environmental IP20 / indoor Dimensional Drawing A Mounting TS35 DIN rail Earthing - Direct earth connection via DIN rail and screw terminals with -G base option - 90 V isolation between DIN rail earth and shield with -EC90 base option Enclosure / Colour Polycarbonate / black Standards IEC 61643-21:2012 SPD connected to telecommunications and signalling networks - Cat C2, D1 AS/NZS 1768:2007 Signalling/Telecommunications surge protection UL 1499 3 rd edition & UL 497B Protectors for data communications and fire-alarm circuits ITU-T K.44: 2012 Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents AS/CA S008:2010 Requirements for Customer Cabling Products AS/NZS 4117:1999 Surge Protective Devices for Telecommunications Applications Shipping Weight 35 g 35 g 35 g 35 g 35 g 35 g 35 g 35 g Customs Tariff 85363000 85363000 85363000 85363000 85363000 85363000 85363000 85363000