SL-300-600 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

  • Industrial (SL) & Medical (SLM) Versions
  • Output Voltages from 12 V to 96 V
  • Power Factor Corrected
  • Remote On/Off
  • Current Share
  • Power Fail Signal
  • Overtemperature Protection SL & SLM Series Input Input Voltage • 90-264 VAC (125-360 VDC) Input Frequency • 44-66 Hz Input Current • 300 W models: 4.4 A at 90 VAC

1.8 A at 230 VAC

600 W models: 8.9 A at 90 VAC

3.5 A at 230 VAC

Inrush Current • 100 A at 230 VAC Power Factor • 0.9 typical Earth Leakage Current • SL models: <2.5 mA at 264 VAC/50 Hz SLM models: <100 µA at 264 VAC/50 Hz Input Protection • 10 A HRC fuse Output Output Voltage • See table Output Voltage Trim • See table Initial Set Accuracy • ±1% max Minimum Load • No minimum load required Start Up Delay • 600 ms max Start Up Rise Time • 150 ms max Hold Up Time • 18 ms min Line Regulation • <0.5% V min to V max Load Regulation • <2.0% for a 0-100% load change Transient Response • 2% max deviation, recovery to within 0.25% in 1 ms for a 10% load change Ripple & Noise • 1% pk-pk max, 20 MHz BW Overvoltage Protection • 120% approx Vnom Overtemperature • Fitted to 600 W models only, Protection recycle mains to reset Overload Protection • 110% typical, constant current Short Circuit Protection • Constant current Temperature • 0.02%/˚C Coefficient Remote On/Off • Output inhibited by shorting ROF pin to 0 V Current Share • Allows up to 5 units to share within 5% xppower.com General Efficiency • 85% typical Isolation • 6000 VDC Input to Output (Y caps disconnected)

2200 VDC Input to Ground

2200 VDC Output to Chassis

Switching Frequency • 30-35 kHz PFC, 45-55 kHz PWM Signals • AC OK - TTL compatible signal is high with reference to 0 V when AC is OK MTBF • 105 kHrs typical per MIL-HDBK-217E at +20 ˚C. Consult office for each model Environmental Operating Temperature • -20 ˚C to +70 ˚C, derate from +40 ˚C to 50% power at +70 ˚C Operating Humidity • 90% RH, non-condensing Storage Temperature • -25 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • Non operating. 100 mm drop on to chassis face Vibration • Operating 5-50 Hz 0.05 mm pk-pk, 50-100 Hz 0.025 mm pk-pk Airflow Direction • Where fitted fans blow air into the unit EMC & Safety Emissions • EN55022, level B conducted EN55022, level A radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals • SL: UL60950, CSA22.2 No.60950 SLM: UL2601-1, CSA C22.2 No.60601-1

2.77 (71.0) 300 W 2.61 (67.0) INPUT EARTH NEUTRAL LINE INTERNAL FAN

600 W ONLY

+V+V+V -V -V -V 4.95 (127.0) 4.33 (111.0) 11.70 (300.0) 11.31 (111.0) A A A A SL & SLM Series Mechanical Details Nominal Output Voltage(2,3) Output Voltage Trim OVP Setting Typical(1) Output Current Code300 W 600 W 12 V 11-14 V 15.3 V 25.0 A 50.0 A 12 24 V 22-29 V 30.7 V 12.0 A 25.0 A 24 36 V 33-42 V 45.9 V 8.0 A 16.5 A 36 48 V 44-57 V 61.2 V 6.0 A 12.5 A 48 60 V 55-70 V 76.5 V 5.0 A 10.0 A 60 96 V 88-114 V 127.5 V 3.0 A 6.0 A C1 Model Numbering Models and Ratings Notes 1. Overvoltage protection is by the inverter shutdown method and can only be reset by disconnecting the input voltage. 2. Output characteristic constant voltage - constant current type, ideal for non-linear loads. 3. Other output voltages available, consult sales for details. Input connectors: 0.37” (9.5mm) pitch M4 barrier block. Signals: 3 X 0.04” (3 X 1.0mm) pins 1.0” (25.4mm) pitch (ROF , power share and AC fail). Fixings (ref ‘A’):M3 ISO Metric (Screws must not penetrate unit by more than 0.20” (5.0mm). Notes 1. 300 W models are convection cooled. 600 W models are fan cooled. 2. Not available on 12 V output. SL = Standard SLM = Medically Approved P = PFC -C = Cover -D = ORing Diode (2) -E = Conformal Coating -M = Ruggedisation -N = Temperature Compensation -T = Overtemperature Protection Inputs Outputs Options EXAMPLE: SL 300 P S 24 - C SL = Standard C = Safety Cover Fitted 300 = Power 24 = Output 24 VDC S = Single Output P = PFC Input 300 600 S = Single No. of Outputs Power (Watts)(1) Style 12 = 12 V 24 = 24 V 48 = 48 V 60 = 60 V C1 = 96 V All dimensions are in inches (mm) Weight: 300 W models - 3.75 lbs (1.7 kg) 600 W models - 4.19 lbs (1.9 kg)