Features
/square4 Conforms to ETSI EN 300 220-3 and EN 301 489-3 /square4 High performance double superhet PLL synthesizer /square4 +27dBm (500mW) RF power output /square4 Data rates up to 5 kbps for standard module /square4 Usable range over 5km /square4 Fully screened. Low profile /square4 Feature-rich interface (RSSI, analogue and digital baseband) /square4 Incorporate a 1200baud modem /square4 Re-programmable via RS232 interface /square4 Low power requirements
Applications
/square4 Amateur Radio /square4 Remote Meter Reading /square4 Asset Tracking and Tracing /square4 Multi-Use Radio Service (MURS) Technical Summary /square4 Operating frequency: Any 3MHz segment in 140 - 175MHz /square4 8 parallel or 255 serial channels /square4 Transmit power: 500mW (+27dBm) nominal /square4 Supply range: +5V regulated /square4 Current consumption: 280mA (at 500mW output) transmit, 20mA receive /square4 Data bit rate: 5kbps max. (standard module) /square4 Receiver sensitivity: -118dBm (for 12 dB SINAD) /square4 Size: 67 x 30 x 9mm SHX1 is small multi- channel 25kHz narrow band VHF transceiver with up to 500mW RF power output. It is usable for 144MHz band amateur, 151MHz US MURS and European 169MHz band high power applications. Figure 1: SHX1-154-5-12K5-MURS 500mW Multichannel VHF transceiver Hartcran House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com Issue 1, 17 August 2012 SHX1
Radiometrix Ltd SHX1 Data Sheet (preliminary) page 2 Figure 2: SHX1 block diagram
Radiometrix Ltd SHX1 Data Sheet (preliminary) page 3 Pin Description NOTES 1. No inversion occurs between TXD and RXD. However , AF out is inverted relative to TXD. 2. PGM, P0 - P3 (parallel channel selects) and TXE are active LOW and have internal 47K pullups to 4v. 3. Open collector output RXD has a 47K pullup to 4V . 4. The software incorporates a 1200baud dumb modem, compatible with that implemented in other Radiometrix narrowband units ( i1200 tones and format ). Modem operation is selected by a serial command. 5. Main serial port (PGM) operates at 2400 baud. (C ommand set is the same as SMX (USA) version). The unit is capable of operating in 'basic' parallel channel select only mode, or in serial controlled 'expanded' mode. 6. If analogue transmit modulation is needed, then connect a series 1uF cap + 500K trimmer (a multiturn is advised) in the 'baseband TXD' circuit. Adjust trimmer for 90% of peak deviation (+/- 2.7kHz) at mean input level. 7. The high current (280mA max.) transmitter supply (5v regulated) is fed to a separate pin, on the RF out connector (pin 6A). The Vcc (pin 4 on the user connector) can tolerate 4.1 - 15v, and draws up to 25mA. Both pins must be supplied at all times (most users connect them to a common +5v supply) Pins Normal mode Modem mode RF 1A NO PIN 2A RF in/out To the antenna 3A RF Gnd RF ground 4A GND 0V 5A GND 0V 6A VCCTX +5V regulated supply for TX 7 User
1 TXD DC coupled input for TTL / CMOS logic NC
2 TXE Transmit enable. Low = TX mode NC
3 GND 0V
4 Vcc DC supply input (+5V regulated) 8
5 P3 Parallel channel select BUSY
6 P2 Parallel channel select MOD TXD
7 P1 Parallel channel select MOD RXD
8 PGM in Serial programming/control input (inverted logic level RS232) PGM in
9 RSSI DC level between 0.5V and 2.5V. 60dB dynami c range 10 RXD Open collector output of data slicer. 47K pu llup to 4V NC 11 AF out 500mV p-p audio. DC coupled, approx 0.8V bias NC Figure 3: SHX1 footprint (Top) view
Radiometrix Ltd SHX1 Data Sheet (preliminary) page 4 Serial interface commands Serial data is sent to the unit on the programming input (PGM). To successfully program the unit, it must be powered Once 'modem' mode has been selected, the unit locks into serial command mode (and the parallel port pins have other functions) until a SETPAR command returns the unit to ordinary parallel operation. Unlike earlier Radiometrix multichannel units, the SHX1 (like the QPX1 and USA versions of SMX1) has separate N and R registers for each channel, on transmit and on receive. In other words, the frequency of each channel is individually programmed in every mode. Channels 8-255 then constitute a sequential table, starting from channel 7 Functionally, the N value for any 'table' channel is derived by multiplying the STEP value by the (channel number -7) and adding it to the N value programmed for channel 7 (the chan 7 " R value" is used throughout the table). The LOADMX command sets an upper limit for usable channel numbers, beyond which the unit reverts to channel 0 Unless a complex frequency map has been selected, all the R value registers are likely to be programmed with the same value Commands include: Commands Function GOCHAN a empty command buffer LDTXN a nnnnn set value of N for channel a , for transmit LD RXN a nnnnn set value of N for channel a , for receive LDTXR a nnnnn set value of R for channel a , for transmit LDRXR a nnnnn set value of R for channel a , for receive LOADST ss set per-channel increment step for table (channels 8 and up) LOADMX a aa set highest valid channel (all channels above this point default to ch0) SETMOD Enable internal modem. Frequency selected by most recent 'gochan' or 'single' SETPAR channel selected by 3 bit parallel input 3 SETSER channel selected by most recent 'gochan' operation RVALUE rrrrr set R register value used by FORCE command FORCE nnnnn set value of N for single channel operation. N value NOT stored in EEPROM. It is necessary to send a FORCE command with a different value of nnnnn when changing from tx to rx or vice versa. GOTEST lock transmitter on, sending 250Hz squarewave (nothing overrides this command: you must power-off the unit) <cr> process entry / clear all buffers # disable command mode Volatile channel set up : A byte with bit 7 set puts the ls nibble into the high 4 bits of a holding register. A byte with bits 6 and 7 set puts the ls nibble into the low 4 bits of the holding register and the uses this value as a channel number to program the PLL. This function does not work if set to parallel mode. At power-up the unit reverse back to the last E2prom stored GOCHAN value a = single digit channel number from 0 to 7 aaa = channel number from 0 to 255 nnnnn = a synthesizer N register value, (up to 65535) rrrrr = the synthesizer R register value, (up to 16383) ALL COMMANDS MUST BE IN UPPER CASE. For transmit: N = channel frequency / (10MHz / R) For receive: N = (channel frequency - 21.4MHz) / (10MHz / R) 10MHz / R = 25KHz, so R = 400 (usually)
Radiometrix Ltd SHX1 Data Sheet (preliminary) page 5 NOTE :
- In 'FORCE' mode the unit is inoperative after a po wer down until either another valid FORCE command is received, or until mode is changed by a GOCHAN, SETPAR or SETSER command.
- FORCE mode does not apply any receive frequency of fset.
- Different values need to be sent when changing fro m transmit to receive and vice versa.
- FORCE is intended mainly for test/diagnostic opera tion.
- A pause of at least 50ms must be allowed between c ommand strings (EEPROM programming time) Modem mode The 'modem' mentioned is a 1200baud RS232 semi-intelligent unit (Transmit keyed when valid serial data is present, so no separate TX control needed. Coding in the datastream also permits the receiver to ignore noise and only output valid serial data) This is a half duplex unit, so collisions between transmitted and received packets must be dealt with by the user If greater modem functionality is needed, then a version (SHZ1) is available which includes a full-function M48A modem device inside the unit, replacing the i1200 functions (case height is increased by 3mm to accommodate the extra circuitry). This "SHZ1" only operates in 'modem' mode (no parallel channel select, no independent transceiver operation)
Ordering Information
Part No. Application Channel spacing Frequency band (MHz) SHX1-144-5 Amateur Radio (e.g. APRS) 25kHz 144.000 - 146.000 SHX1-151-5-12k5-MURS Multi-Use Radio Service (MURS) in USA, Canada 12.5kHz CH0:151.820 – CH4:154.600MHz SHX1-169-5-12K5 Meter Reading, Asset Tracking and Tracing 12.5kHz CH0:169.40625 – CH15:169.59375 CH16:169.61875- CH31:169.806250 SHX1-169-5 25kHz CH0:169.412500- CH7:169.587500 CH8:169.62500- CH15:169.8000
Radiometrix Ltd SHX1 Data Sheet (preliminary) page 6 Condensed specifications (All details are provisional) Frequency Any 3MHz segment in 140 - 175MHz (TX and RX frequencies need not be the same) Frequency stability +/-5ppm (better than ±1.5kHz) Channel spacing 12.5kHz / 20kHz / 25kHz (factory set) Number of channels 8 parallel or 255 serial channels Supply Receive 5.0V regulated at 20mA Transmit: 5.0V regulated at 280mA for 500mW output Operating temperature -20 to +70 οC (Storage -30 to +70 οC) Spurious radiations Compliant with ETSI EN 300 220- 3 and EN 301 489-3 Interface User 11 pin 0.1" pitch molex RF and TX supply 5 pin 0.1" pitch molex Recommended PCB hole size 1.2mm (min.) Size 67 x 30 x 9mm Transmitter Output power +27dBm (500mW) TX on switching time <50 ms Modulation type FM, FSK (F1D, F3D) TX modulation bandwidth DC – 3kHz Deviation ±3kHz ( ±1.5kHz for 12.5kHz channel variant) nominal Adjacent channel TX power -37dBm TX spurii <-40dBm Inputs Data (CMOS/TTL compatible) Receiver Sensitivity -118dBm for 12dB SINAD image / spurious -65dB blocking -86dB adjacent channel -65dB (tested per ETSI EN300 086) Outputs RSSI, Audio, Data
231 Kenton Lane
Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000 R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/radiocomms/ifi/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)845 456 3000 or 020 7981 3040 Fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk European Radiocommunications Office (ERO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk