Features
- Matched Red Amber, Converted Green, Blue and Blue bump Chipset with for 0.2” / 0.3” Pico projection applications
- Standard 3535 SMT package
- Low thermal resistance: Red-Amber 1.9°C/W, Converted Green, Blue and Blue bump 1.6°C/W
- Lambertian emitting profile
- Flat surface emission for high collection efficiency and low optical losses
- Wide color gamut with dominant wavelengths: Red-Amber 613 nm / Converted Green (filtered spectrum) 555 nm / Blue 459 nm at 0.98 A, 25°C Table of Contents Angular Distribution and Typical
Product Family Chip Area Color Package Configuration Bin Kit SFT: Surface-Mount Flat-Top 14: 1.4 mm2 RA: Red Amber CG: Converted Green B: Blue BP: Blue Pump F35: 3535 EMC SMD See Mechanical Drawing section Refer to ordering part numbers in this document SFT 14 <XX> F35 <Bin kit> Note: 1. Flux Bin listed is minimum bin shipped, higher bins may be included at Luminus’ discretion. Color Luminous Flux Wavelength Bin Bin Kit Ordering Code Ordering Part NumberMin. Flux Bin Min. Flux Red Amber 1C 150 N/A MPC SFT-14-RA-F35-MPC 1D 165 N/A MPD SFT-14-RA-F35-MPD Converted Green 2G 455 N/A MPG SFT-14-CG-F35-MPG 2H 490 N/A MPH SFT-14-CG-F35-MPH 2J 530 N/A MPJ SFT-14-CG-F35-MPJ Blue 4D 1.15 B2, B6, B7 EPD SFT-14-B-F35-EPD 4E 1.30 B2, B6, B7 EPE SFT-14-B-F35-EPE Blue Pump 4E 1.30 B0, B1 EPE SFT-14-BP-F35-EPE 4F 1.45 B0, B1 EPF SFT-14-BP-F35-EPF Ordering Part Numbers1
Ordering Information
2PDS-003027 Rev03 www.luminus.com
All SFT-14 LEDs are tested for luminous flux/dominant wavelength and placed into one of the following flux/wavelength bins. The binning structure is universally applied across each monochromatic color of the SFT-14 product line. Color Luminous Flux Bin3 Binning @ 0.98 A, Tc= 25°C4 Minimum Flux (lm) Maximum Flux (lm) Red Amber 1A 125 140 1B 140 150 1C 150 165 1D 165 180 1E 180 200 1F 200 220 Converted Green 2D 360 395 2E 395 425 2F 425 455 2G 455 490 2H 490 530 2J 530 580 2K 580 625 Blue / Blue Pump 4C 1.05 1.15 4D 1.15 1.30 4E 1.30 1.45 4F 1.45 1.60 4G 1.60 1.75 4H 1.75 1.90 Flux Bins1,2 Note: 1. Luminus maintains a +/- 6% tolerance on flux measurements. 2. Products are production tested then sorted and packed by bin. 3. Individual bins are not orderable. Please refer to the Product Ordering information page for a list of orderable bin kits. 4. Tc= Case temperature. SFT -14 Product Datasheet 3PDS-003027 Rev03 www.luminus.com
All SFT-14 LEDs are tested for luminous flux/dominant wavelength and placed into one of the following flux/wavelength bins. The binning structure is universally applied across each monochromatic color of the SFT-14 product line. Note: 1. Luminus maintains a +/- 6% tolerance on flux measurements. 2. Products are production tested then sorted and packed by bin. 3. Individual bins are not orderable. Please refer to the Product Ordering information page for a list of orderable bin kits. 4. Tc= Case temperature. SFT -14 Product Datasheet 4PDS-003027 Rev03 www.luminus.com Color Dominant Wavelength Bin3 Binning @ 0.98 A, Tc= 25°C4 Minimum Wavelength (nm) Maximum Wavelength (nm) Blue Pump B0 444 449 B1 449 455 Blue B2 (Under EOL) 455 465 B6 454 462 B7 462 465 Dominant Wavelength Bins
Symbol Red Amber Converted Green Blue & Blue Pump Unit Forward Current (Single pulse 20 ms or Pulsed)2,3,4 If min 0.2 0.2 A If max 4.2 5.6 Forward Current Pulsed2,3,4 Frequency >240Hz, Duty <70% Ifp max 5.6 6.0 A Forward Surge Current (Pulsed)2,3,4 Frequency >240Hz, duty cycle <10% or t=1ms) Isurge max 6.3 6.6 A Storage Temperature Ts min -40 -40 Ts max 100 100 Junction Temperature Tj max 110 150 °C ESD sensitivity ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) VESD 2000 2000 V SFT -14 Product Datasheet Note: 1. All ratings are based on standard testing conditions at drive current 0.98 A, 20 ms single pulse at Tc = 25°C. 2. In pulsed operation, rise time from 10% to 90% of forward current should be larger than 0.5 microseconds. 3. Product performance and lifetime data is specified at recommended forward drive current. Sustained operation at or near absolute minimum current may result in a reduction of device performance and device lifetime compared to recommended forward drive current. 4. Sustained operation above maximum current is not recommended and will result in a reduction of device lifetime. 5PDS-003027 Rev03 www.luminus.com
Optical and Electrical Characteristics Symbol Red Amber Converted Green Blue Blue Pump Unit Emitting Area AE 1.40 1.40 1.40 1.40 mm2 Peak Luminous Flux2 ΦV 158 490 45 40 lm Peak Radiometric Flux2 ΦE 0.54 1.06 1.50 1.75 W Forward Voltage Vf min 2.0 2.5 2.5 2.5 VVf 2.3 3.0 3.0 3.0 Vf max 3.0 3.6 3.6 3.6 Dominant Wavelength λd min 609 545 454 444 nmλd 613 555 459 448 λd max 621 565 465 455 FWHM- Spectral bandwidth at 50% of ΦV ∆λ1/2 16 98 19 19 nm Chromaticity Coordinates3 CIE x 0.66 0.33 0.15 0.15 CIE y 0.32 0.56 0.04 0.04 Chromaticity Coordinates (filtered spectrum)3,4 CIE x - 0.31 - - CIE y - 0.63 - - Thermal Characteristics Real thermal resistance (junction-case) Rth real (j-c) 1.90 1.60 1.60 1.60 °C/W SFT -14 Product Datasheet Note: 1. Product test condition: 0.98 A, 25°C case temperature. 2. Typical flux at typical dominant wavelength. 3. CIE 1931 chromaticity diagram coordinates, normalized to X+Y+Z=1. 4. Optical filter of 50% cut off range between 580 nm and 600 nm applied in typical projection display engine. 5. Thermal resistance values are based on modeled results correlated to measured Rth(j-c) data using Forward Voltage sensitivity parametric method, compliant with JEDEC Standards JESD51-14. 6. For optimal results, Luminus recommends customer PCB Design per guidelines from Luminus application note, “Design Guidelines for SFT Chipset Assembly”. 6PDS-003027 Rev03 www.luminus.com
Relative Luminous Flux - Red Amber Forward current: φv/φv(0.98 A) Single pulse 20 ms, Tc = 25°C 50% 100% 150% 200% 250% 300% 350% 400% 0 1 2 3 4 5 Relative Luminous Flux If (A) Temperature: φv/φv(25°C) Single pulse 20 ms, If = 0.98 A 30% 40% 50% 60% 70% 80% 90% 100% 20 30 40 50 60 70 80 90 100 Relative Luminous Flux TC (°C) Forward Voltage - Red Amber Forward current: Vf = V(If) Single pulse 20 ms, Tc = 25°C 1.50 2.00 2.50 3.00 3.50 4.00 0 1 2 3 4 5 Voltage (Vf) If (A) Temperature: ∆Vf = V(Tc) - V(25°C) Single pulse 20 ms, If = 0.98 A -0.15 -0.12 -0.09 -0.06 -0.03 0.00 20 30 40 50 60 70 80 90 100 Δ Forward Voltage (Vf) TC (°C) Dominant Wavelength Shift - Red Amber Forward current: ∆λd= λd(If) - λd(0.98 A) Single pulse 20 ms, Tc = 25°C -1.0 0.0 1.0 2.0 3.0 4.0 5.0 0 1 2 3 4 5 Δ Dominant Wavelength (λd) If (A) Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.98 A -1.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 20 30 40 50 60 70 80 90 100 Δ Dominant Wavelength (λd) TC (°C) 7PDS-003027 Rev03 www.luminus.com
Relative Luminous Flux - Converted Green Forward current: φv/φv(0.98 A) Single pulse 20 ms, Tc = 25°C 50% 100% 150% 200% 250% 300% 350% 400% 450% 0 1 2 3 4 5 6 7 Relative Luminous Flux If (A) Temperature: φv/φv(25°C) Single pulse 20 ms, If = 0.98 A 85% 88% 90% 93% 95% 98% 100% 20 30 40 50 60 70 80 90 100 110 120 Relative Luminous Flux TC (°C) Forward Voltage - Converted Green Forward current: Vf = V(If) Single pulse 20 ms, Tc = 25°C 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 0 1 2 3 4 5 6 7 Forward Voltage (Vf) If (A) Temperature: ∆Vf = V(Tc) - V(25°C) Single pulse 20 ms, If = 0.98 A -0.15 -0.12 -0.09 -0.06 -0.03 0.00 20 30 40 50 60 70 80 90 100 110 120 Δ Forward Voltage (Vf) TC (°C) Dominant Wavelength Shift - Converted Green Forward current: ∆λd= λd(If) - λd(0.98 A) Single pulse 20 ms, Tc = 25°C -3.0 -2.0 -1.0 0.0 1.0 2.0 3.0 0 1 2 3 4 5 6 7 Δ Dominant Wavelength (λd) If (A) Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.98 A -1.0 0.0 1.0 2.0 20 30 40 50 60 70 80 90 100 110 120 Δ Dominant Wavelength (λd) TC (°C) 8PDS-003027 Rev03 www.luminus.com
Relative Radiometric Flux - Blue / Blue Pump Forward current: φv/φv(0.98 A) Single pulse 20 ms, Tc = 25°C 50% 100% 150% 200% 250% 300% 350% 400% 450% 0 1 2 3 4 5 6 7 Relative Radiometric Flux If (A) Temperature: φv/φv(25°C) Single pulse 20 ms, If = 0.98 A 80% 85% 90% 95% 100% 20 30 40 50 60 70 80 90 100 110 120 Relative Radiometric Flux TC (°C) Forward Voltage - Blue / Blue Pump Forward current: Vf = V(If) Single pulse 20 ms, Tc = 25°C 2.50 3.00 3.50 4.00 4.50 0 1 2 3 4 5 6 7 Forward Voltage (Vf) If (A) Temperature: ∆Vf = V(Tc) - V(25°C) Single pulse 20 ms, If = 0.98 A -0.20 -0.15 -0.10 -0.05 0.00 20 30 40 50 60 70 80 90 100 110 120 Δ Forward Voltage (Vf) TC (°C) Dominant Wavelength Shift - Blue / Blue Pump Forward current: ∆λd= λd(If) - λd(0.98 A) Single pulse 20 ms, Tc = 25°C -5.0 -4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0 3.0 4.0 5.0 0 1 2 3 4 5 6 7 Δ Dominant Wavelength (λd) If (A) Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.98 A -1.0 0.0 1.0 2.0 3.0 4.0 5.0 20 30 40 50 60 70 80 90 100 110 120 Δ Dominant Wavelength (λd) TC (°C) 9PDS-003027 Rev03 www.luminus.com
Angular Intensity Distribution Angular Distribution and Typical Spectrum Typical Spectrum 0.2 0.4 0.6 0.8 1.2 350 400 450 500 550 600 650 700 750 Intensity (a.u.) Wavelength (nm) Red CG Blue Iref = f(Φ); Tc = 25°C Φref = f(λ); If = 0.98 A; Tc = 25°C 10PDS-003027 Rev03 www.luminus.com Red Amber Converted Green Blue / Blue Pump
11PDS-003027 Rev03 www.luminus.com SMT Rework Guideline Manual Hotplate Reflow Hot Air Gun Reflow Heating Time < 60 sec Hotplate Temperature < 245°C < 150°C Temperature Time Preheat RT to 150°C 1 - 2.5°C/sec Soak 150°C to 180°C 0.4 - 1°C/sec Reflow 180 to TL + 20°C 3 - 6°C/sec Cool down Peak to below 150°C 3 - 7°C/sec Liquidus Temperature, TL (SAC305 = 220°C) Peak Temperature (235 - 245°C) Time Above Liquidus (45 - 90 sec) 65 -> 200°C, 120 - 250 sec max Note: 1. Product complies to Moisture Sensitivity Level 3 (MSL 3). 2. The numbers in the table are specific to SAC305. Luminus recommends using an SAC305 solder paste with a no-clean flux for RoHS compliant products. 3. During the pick and place process, ensure the pick-up tool does not touch any die components. 4. Use of a multi-zone IR reflow oven with a nitrogen blanket is recommended. 5. Time-temperature profile of the reflow process showing the four functional profile zones are defined in IPC-7801. Temperature is referenced to the center of the PCB. 6. Luminus recommends to use the solder paste data sheet information as a starting point in time-temperature process development. 7. These are general guidelines. Consult the solder paste manufacturer’s datasheet for guidelines specific to the alloy and flux combination used in your application. For more information, please refer to: https://luminusdevices.zendesk.com/hc/en-us/articles/360060306692-How-do-I-Reflow-Solder-Luminus-SMD-Components- 8. For any technical questions about soldering process, please contact Luminus at techsupport@luminus.com.
12PDS-003027 Rev03 www.luminus.com SFT -14 [Red Amber / Blue] in “F35” Package Configuration SFT -14 [Converted Green] in “F35” Package Configuration Note: 1. Converted Green differs from Red Amber/Blue in only the emitting surface is slightly larger than the underlaying die.
13PDS-003027 Rev03 www.luminus.com Note: 1. Layout is common to all colors. For recommended solder profiles, see page 13. 2. Optimal LED performance is dependent on a proper system design. Please review the Luminus application note, “Design Guidelines for SFT Chipset Assembly.” 3. Contact Luminus for more detail.
14PDS-003027 Rev03 www.luminus.com Shipping Reel Outline Parameter Dimension (mm) A0 3.80 +/- 0.10 B0 4.00 +/- 0.10 K0 1.20 +/- 0.10 P0 4.00 +/- 0.10 P1 8.00 +/- 0.10 P2 2.00 +/- 0.05 T 0.30 +/- 0.05 E1 1.75 +/- 0.10 F 5.50 +/- 0.05 D0 1.55 +/- 0.05 D1 1.55 +/- 0.05 W 12.00 +/- 0.01 Parameter Quantity (pcs) Pieces per reel 250 500 Note 1. The quantity per reel is not orderable. 2. Minimum order quantity: 500 pcs.
15PDS-003027 Rev03 www.luminus.com Reel Package Humidity Card (bag) Desiccant (bag) Vacuum sealed antistatic bag Label: contains the type, Lot #, Quality, Product parameters Humidity card (bag) Desiccant (bag) Vacuum sealed anti-static bag Label contains the type, lot number, quantity and product parameters Box Packaging Information *Capacity 5 reels per box *Capacity 10 reels per box Label: contains the type, Lot #, Quality, Product parameters Label: contains the type, Lot#, Label: contains the type, Lot#, Quality, Product parametersQuality, Product parameters
Label Fields:
- CPN: Luminus ordering part number
- CID: Customer’s part number
- QTY: Quantity of devices in pack
- Flux: Bin as defined on page 3
- Voltage: NA
- Color: NA
- CRI: NA
- Lot ID: For Luminus internal use
- Reel ID: For Luminus internal use Packing Configuration:
- Maximum of 500 devices per reel
- Partial reel may be shipped
- Each pack is enclosed in anti-static bag
- Shipping label is placed on top of each pack XXX-XX-XXXX-XXXX-XXXXXXXXX 500 Reel ID 16PDS-003027 Rev03 www.luminus.com
This product is sensitive to static electricity, and care should be taken when handling them. Static electricity or surge voltage will damage the LEDs. It is recommended to wear an anti-electrostatic wristband or anti-electrostatic gloves when handling the LEDs. All devices, equipment and machinery must be properly grounded. It is recommended that measures be taken to isolate LED processing equipment from potential sources of voltage surges. Reference: APN-002815 Electrical Stress Damage to LEDs and How to Prevent It Eye Safety According to the test specification risk group IEC 62471-Non-GLS under 0.98 A, this product complies to Risk group 2 (RG2) Moderate risk. Do not stare at operating lamp, may be harmful to the eyes. For more information, please refer to: https://luminusdevices.zendesk.com/hc/en-us/articles/10532958752397 17PDS-003027 Rev03 www.luminus.com
Revision History
Rev Date Description of Change 01 08/23/2021 Revision 01 release. 02 02/04/2022 1.Add CG flux bins 2.Make wavelength bin B2 only on SFT-14-B ordering part number 3.Update PDS format. 03 01/25/2024 Update datasheet template, ordering part numbers and bin-kit codes. SFT -14 Product Datasheet 18PDS-003027 Rev03 www.luminus.com