Features

  • Blue and Blue Pump LED with 5.0 mm 2 emitting area designed for display
  • Complement with PTM-50X Red Amber and Converted Green for best projection brightness and color gamut
  • Dominant wavelength: Blue/Blue Pump 457/444 nm (Typ.)
  • LED die precision mounted on low thermal resistance isolated MC-PCB package
  • Thermistor pad allows option for precise thermal management
  • Drive current up to 16 A
  • Chipset array in series enabling lower drive current
  • Windowless package allows for closer collection optics and brighter system solutions
  • LED emitting area optimized for micro-display diagonal sizes ranging from 0.45” to 0.65” Table of Contents Angular Distribution and Typical

Product Family Chip Area Color Package Configuration Bin Kit4,5 PTM: Projection Technology Multi-Die 50: 5.0 mm2 X: Isolated B: Blue BP: Blue Pump L34: No Connector, Core board, Windowless (See Mechanical Drawing section) Refer to ordering part numbers in this document PTM 50X ## L34 <Bin kit> Note: 1. Ordering part numbers represent bin kits (group of bins that are shippable for a given ordering part number) 2. Flux Bin listed is minimum bin shipped, higher bins may be included at Luminus’ discretion. 3. Ordering Part number is default to L34 package configuration. 4. Individual flux bins are not orderable. 5. See Bin Kit and Flux / Power bin definitions on page 3. Color Radiometric Flux2 Bin kit Ordering Code Wavelength Bin Ordering Part Number3 Min. Flux Bin Min. Power Blue 4F 19.6 W EPF B6, B7 PTM-50X-B-L34-EPF 4G 21.3 W EPG B6, B7 PTM-50X-B-L34-EPG Blue Pump 4G 21.3 W EPG B0, B1 PTM-50X-BP-L34-EPG 4H 23.3 W EPH B0, B1 PTM-50X-BP-L34-EPH Ordering Part Numbers1

Ordering Information

2PDS-003148 Rev 01 www.luminus.com

Color Radiometric Flux Bin3 Binning @ 10 A, Tj= 25°C4,5 Minimum Power (W) Maximum Power (W) Blue / Blue Pump 4F 19.6 21.3 4G 21.3 23.3 4H 23.3 25.3 4J 25.3 27.3 Flux Bins1,2 Note: 1. Luminus maintains a +/- 6% tolerance on flux and power measurements, and a +/- 1nm tolerance on wavelength measurements. 2. Products are production tested then sorted and packed by bin. 3. Individual bins are not orderable. Please refer to the Product Ordering information page for a list of orderable bin kits. 4. Product test condition: 10 A, 20 ms single pulse, 25°C = heat sink temperature = Ths= Tj 5. Tj= Junction temperature. 6. Wavelength bins are not orderable. Wavelength bins are displayed in product label. PTM-50X-B/BP Product Datasheet 3PDS-003148 Rev 01 www.luminus.com Binning Structure Color Wavelength Bin3 Binning @ 10 A, Tj= 25°C4,5 Minimum Wavelength (nm) Maximum Wavelength (nm) Blue Pump B0 441 447 B1 447 450 Blue B6 453 460 B7 460 465 Dominant Wavelength Bins1,2

Absolute Maximum Reverse Drive Current (CW or Pulsed)1,2 Ir max 0 mA Absolute Minimum Forward Current (CW or Pulsed)2 If min 0.2 A Absolute Maximum Forward Current (CW)3 If max CW 13.0 Absolute Maximum Forward Current (Pulsed)3,4 (Frequency > 240Hz, duty cycle < 70%) If max Pulsed 16.0 Absolute Maximum Surge Current3,4 (Frequency >240Hz, duty cycle = 10%, t=1ms) Isurge max 17.0 A Absolute Minimum Storage Temperature Ts min -40 Absolute Maximum Storage Temperature Ts max 100 Absolute Maximum Junction Temperature Tj max 150 °C ESD sensitivity ANSI/ESDA/JEDEC JS-001 (HBM, Class 3A) VESD 4000 V PTM-50X-B/BP Product Datasheet Note: 1. Reverse Current Operation is not allowed. 2. Product performance and lifetime data is specified at recommended forward drive currents. Sustained operation at or near absolute minimum currents may result in a reduction of device performance and device lifetime compared to recommended forward currents. 3. Sustained operation above maximum currents is not recommended and will result in a reduction of device lifetime compared to specified maximum forward drive currents. Device lifetimes will depend on junction temperature. 4. In pulsed operation, rise time from 10% to 90% of forward current should be larger than 0.5 microseconds. 4PDS-003148 Rev 01 www.luminus.com

General Characteristics Symbol Blue Blue Pump Unit Emitting Area AE 4.93 4.93 mm2 Emitting Area Dimension 3.30 x 1.54 3.30 x 1.54 mm x mm Optical and Electrical Characteristics1 Test Pulse Duration 20 20 ms Test Peak Drive Current2 If 10 10 A Peak Luminous Flux2 φv 920 500 lm Peak Radiometric Flux2 Φr 22.7 25.7 W Forward Voltage Vf min 6.8 6.8 VVf 7.4 7.4 Vf max 8.0 8.0 Dominant Wavelength λd miin 453 440 nmλd 457 444 λd max 465 450 Peak Wavelength λp 453 436 nm FWHM- Spectral bandwidth at 50% of Φr ∆λ1/2 20 20 nm Chromaticity Coordinates3 CIE x 0.15 0.16 CIE y 0.03 0.01 Thermal Characteristics Thermal Resistance (junction to case) real4 RѲj-c real 0.68 0.68 °C/W Thermal Resistance (junction to case) electrical4 RѲj-c electrical 0.46 0.44 °C/W PTM-50X-B/BP Product Datasheet Note: 1. Characteristics at 10 A, 20 ms single pulse, 25°C 2. Unless otherwise noted, values listed are typical. All ratings are based on operation with a constant temperature = 25°C = Ths = Tj 3. In CIE 1931 chromaticity diagram coordinates, normalized to X+Y+Z=1. 4. Measurements are in accordance with JEDEC 51-14. 5PDS-003148 Rev 01 www.luminus.com

Relative Luminous Flux - Blue Forward current: φv(If)/φv(10 A), Tj = 25°C, 20 ms single pulse Temperature: φv(Tj)/φv(25°C), If = 10 A, 20 ms single pulse Relative Radiometric Flux - Blue Forward current: Φr(If)/Φr(10 A), Tj = 25°C, 20 ms single pulse Temperature: Φr(Tj)/Φr(25°C), If = 10 A, 20 ms single pulse 6PDS-003148 Rev 01 www.luminus.com Forward Voltage - Blue Forward current: Vf = V(If), Tj = 25°C, 20 ms single pulse Temperature: ∆Vf = V(Tj) - V(25°C), If = 10 A, 20 ms single pulse

Dominant Wavelength Shift - Blue Forward current: ∆λd= λd(If) - λd(10 A), Tj = 25°C, 20 ms single pulse Temperature: ∆λd= λd(Tj) - λd(25°C), If = 10 A, 20 ms single pulse 7PDS-003148 Rev 01 www.luminus.com Peak Wavelength Shift - Blue Forward current: ∆λp= λp(If) - λp(10 A), Tj = 25°C, 20 ms single pulse Temperature: ∆λp= λp(Tj) - λp(25°C), If = 10 A, 20 ms single pulse

Relative Luminous Flux - Blue Pump Forward current: φv(If)/φv(10 A), Tj = 25°C, 20 ms single pulse Temperature: φv(Tj)/φv(25°C), If = 10 A, 20 ms single pulse Relative Radiometric Flux - Blue Pump Forward current: Φr(If)/Φr(10 A), Tj = 25°C, 20 ms single pulse Temperature: Φr(Tj)/Φr(25°C), If = 10 A, 20 ms single pulse 8PDS-003148 Rev 01 www.luminus.com Forward Voltage - Blue Pump Forward current: Vf = V(If), Tj = 25°C, 20 ms single pulse Temperature: ∆Vf = V(Tj) - V(25°C), If = 10 A, 20 ms single pulse

Dominant Wavelength Shift - Blue Pump Forward current: ∆λd= λd(If) - λd(10 A), Tj = 25°C, 20 ms single pulse Temperature: ∆λd= λd(Tj) - λd(25°C), If = 10 A, 20 ms single pulse 9PDS-003148 Rev 01 www.luminus.com Peak Wavelength Shift - Blue Pump Forward current: ∆λp= λp(If) - λp(10 A), Tj = 25°C, 20 ms single pulse Temperature: ∆λp= λp(Tj) - λp(25°C), If = 10 A, 20 ms single pulse

Angular Intensity Distribution1 Angular Distribution and Typical Spectrum Typical Spectrum2 Iref = f(Φ); Tj = 25°C Φref = f(λ); If = 10 A; Tj = 25°C 10PDS-003148 Rev 01 www.luminus.com Note: 1. For any specific device, slight variations may be expected. 2. Typical spectrum at recommended peak drive current. Please contact Luminus to obtain data in Excel format. Blue Blue Pump

11PDS-003148 Rev 01 www.luminus.com Soldering Profile SMT Rework Guideline Manual Hotplate Reflow Hot Air Gun Reflow Heating Time < 60 sec Hotplate Temperature < 245°C < 150°C Note: 1. Product complies to Moisture Sensitivity Level 1 (MSL 1). 2. The numbers in the table are specific to SAC305. Luminus recommends using an SAC305 solder paste with a no-clean flux for RoHS compliant products. 3. During the pick and place process, ensure the pick-up tool does not touch any die components. 4. Use of a multi-zone IR reflow oven with a nitrogen blanket is recommended. 5. Time-temperature profile of the reflow process showing the four functional profile zones are defined in IPC-7801. Temperature is referenced to the center of the PCB. 6. Luminus recommends to use the solder paste data sheet information as a starting point in time-temperature process development. 7. These are general guidelines. Consult the solder paste manufacturer’s datasheet for guidelines specific to the alloy and flux combination used in your application. For more information, please refer to: https://luminusdevices.zendesk.com/hc/en-us/articles/360060306692-How-do-I-Reflow-Solder-Luminus-SMD-Components- 8. For any technical questions about soldering process, please contact Luminus at techsupport@luminus.com. Temperature Time Preheat RT to 150°C 1 - 2.5°C/sec Soak 150°C to 180°C 0.4 - 1°C/sec Reflow 180 to TL + 20°C 3 - 6°C/sec Cool down Peak to below 150°C 3 - 7°C/sec Liquidus Temperature, TL (SAC305 = 220°C) Peak Temperature (235 - 245°C) Time Above Liquidus (45 - 90 sec) 65 -> 200°C, 120 - 250 sec max

12PDS-003148 Rev 01 www.luminus.com Note: 1. Die Tilt: 1° Maximum, Die Rotation: ±1°. 2. Contact within silicone dam area is prohibited. 3. Recommended connector: Manufacturer: Tarng-Yu; Part# TU1502WGR-10S-GO-M8-NL-A. 4. Recommended female connector: Manufacturer: Tarng-Yu; Part# TU1502HNO-10; contact terminal part#TU1502TGO-GO. 5. LED coreboard backside is electrically isolated. 6. LED emitter and wirebond not covered, contact within the silicone dam area is prohibited.

13PDS-003148 Rev 01 www.luminus.com Note: 1. Each tray contains 10 units. 2. All dimensions are in millimeter ± 0.25 mm. 3. For detailed drawing of shipping tray, please refer to document TO-1190, available upon request.

Label Fields:

  • CPN: Luminus ordering part number
  • CID: Customer’s part number
  • QTY: Quantity of devices in pack
  • Flux: Bin as defined on page 3
  • Voltage: NA
  • Color: Bin as defined on page 3
  • CRI: NA Packing Configuration:
  • Stack of 5 trays with 10 devices per tray
  • Partial pack or tray may be shipped
  • Each pack is enclosed in anti-static bag
  • Shipping label is placed on top of each pack XXX-XX-XXXX-XXXX-XXXXXXXXX Box ID 14PDS-003148 Rev 01 www.luminus.com XXX

15PDS-003148 Rev 01 www.luminus.com Static Electricity This product is sensitive to static electricity, and care should be taken when handling them. Static electricity or surge voltage will damage the LEDs. It is recommended to wear an anti-electrostatic wristband or anti-electrostatic gloves when handling the LEDs. All devices, equipment and machinery must be properly grounded. It is recommended that measures be taken to isolate LED processing equipment from potential sources of voltage surges. Reference: APN-002815 Electrical Stress Damage to LEDs and How to Prevent It Eye Safety According to the test specification risk group IEC 62471: 2006-Non-GLS under 10 A, this product complies to Risk group 3 (RG3) High risk. Do not stare at operating lamp, eye injury may result. For more information, please refer to: https://luminusdevices.zendesk.com/hc/en-us/articles/10532958752397

Revision History

Rev Date Description of Change 01 06/27/2024 Initial release PTM-50X-B/BP Product Datasheet 16PDS-003148 Rev 01 www.luminus.com