SFM-03X-RAB LUMINUS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 16
Technical content
Features
- Co-packaged Red Amber and Blue LEDs with each 0.35 mm 2 emitting area designed for high current density projection applications
- Emission area size and aspect ratio optimized for 0.16” / 0.2” micro display panels
- Compact 3030 SMT package
- Typical Dominant Wavelength: 612 nm (Red-Amber) and 457 nm (Blue)
- Unencapsulated, windowless monolithic emitter allowing proximity optics, resulting in simpler and more efficient optical collection
- Matched SFT-03X-CG for 2-channel projectors
- Large dynamic range: up to 1.4 A (Red-Amber) and 2 A (Blue) peak drive current Table of Contents Angular Distribution and Typical
- Stand alone and embedded pico-projectors based on 0.16” and 0.2” class micro displays
Product Family Chip Area Color Package Configuration Bin Kit SFM: Surface mount Flat top Multi-chip windowless format 03: 0.35 mm2 X: Technology indicator RAB: Red-Amber and Blue J30: 3.0 mm x 3.0 mm Electrical and Thermal isolated SMT package Refer to ordering part numbers in this document SFM 03X RAB J30 <Bin kit> Note: 1. Flux Bin listed is minimum bin shipped, higher bins may be included at Luminus’ discretion. Color Luminous Flux Bin Kit Ordering Code Ordering Part NumberRed Amber Blue Min. Flux Bin Min. Flux (lm) Min. Flux (mW) RAB 1Z 30 300 MPZ SFM-03X-RAB-J30-MPZ 1A 33 300 MPA SFM-03X-RAB-J30-MPA Ordering Part Numbers1
Ordering Information
2PDS-003157 Rev 01 www.luminus.com
All SFM-03X LEDs are tested for luminous flux/dominant wavelength and placed into one of the following flux/wavelength bins. The binning structure is universally applied across each monochromatic color of the SFM-03X product line. Color Flux Bin3 Binning @ 0.25 A, Tc= 25°C Red Amber Blue Min. Flux (lm) Max. Flux (lm) Min. Flux (mW) Max. Flux (mW) RAB 1Z 30 33 300 400 1A 33 38 300 400 1B 38 43 300 400 1C 43 50 300 400 1D 50 55 300 400 Flux Bins1,2 Note: 1. Luminus maintains a +/- 6% tolerance on flux measurements. 2. Products are production tested then sorted and packed by bin. 3. Individual bins are not orderable. Please refer to the Product Ordering information page for a list of orderable bin kits. 4. Tc= Case temperature. SFM-03X-RAB Product Datasheet 3PDS-003157 Rev 01 www.luminus.com
Symbol Red Amber Blue Unit Forward Current (Single pulse 20 ms or Pulsed)2,3,4 If min 0.1 0.1 A If max 1.05 1.4 Forward Current Pulsed 2,3,4 Frequency >240Hz, Duty <70% Ifp max 1.4 2.0 A Forward Surge Current (Pulsed) 2,3,4 Frequency >240Hz, duty cycle <10% or t=1ms) Isurge max 1.55 2.2 A Storage Temperature Ts min -40 -40 Ts max 100 100 Junction Temperature Tj max 110 150 °C ESD sensitivity ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) VESD 8000 8000 V SFM-03X-RAB Product Datasheet Note: 1. All ratings are based on standard testing conditions at drive current 0.25 A, 20 ms single pulse at Tc = 25°C. 2. In pulsed operation, rise time from 10% to 90% of forward current should be larger than 0.5 microseconds. 3. Product performance and lifetime data is specified at recommended forward drive current. Sustained operation at or near absolute minimum current may result in a reduction of device performance and device lifetime compared to recommended forward drive current. 4. Sustained operation above maximum current is not recommended and will result in a reduction of device lifetime. 4PDS-003157 Rev 01 www.luminus.com
Optical and Electrical Characteristics Symbol Red Amber Blue Unit Emitting Area AE 0.35 0.35 mm2 Emitting Area Dimension 0.75 x 0.46 0.75 x 0.46 mm Peak Luminous Flux2 ΦV 38 13 lm Peak Radiometric Flux2 ΦE 0.14 0.38 W Forward Voltage Vf min 1.7 2.6 VVf 2.2 3.0 Vf max 2.8 3.5 Dominant Wavelength λd min 610 450 nmλd 612 457 λd max 620 460 FWHM- Spectral bandwidth at 50% of ΦV ∆λ1/2 16 19 nm Chromaticity Coordinates3 CIE x 0.67 0.15 CIE y 0.32 0.03 Thermal Characteristics Real thermal resistance (junction-case) Rth real (j-c) 10 8.0 °C/W Electrical thermal resistance4,5(junction-case) Rth elec.(j-c) 7.7 4.2 °C/W SFM-03X-RAB Product Datasheet Note: 1. Product test condition: 0.25 A, 25°C case temperature. 2. Typical flux at typical dominant wavelength. 3. CIE 1931 chromaticity diagram coordinates, normalized to X+Y+Z=1. 4. Thermal resistance values are based on modeled results correlated to measured Rth(j-c) data using Forward Voltage sensitivity parametric method, compliant with JEDEC Standards JESD51-14. 5PDS-003157 Rev 01 www.luminus.com
Relative Luminous Flux - Red Amber Forward current: φv/φv(0.25 A) Single pulse 20 ms, Tc = 25°C Temperature: φv/φv(25°C) Single pulse 20 ms, If = 0.25 A 30% 40% 50% 60% 70% 80% 90% 100% 110% 20 30 40 50 60 70 80 90 100 Relative Luminous Flux Tc (°C) Forward Voltage Shift - Red Amber Forward current: Vf = V(If) Single pulse 20 ms, Tc = 25°C Temperature: ∆Vf = V(Tc) - V(25°C) Single pulse 20 ms, If = 0.25 A -0.15 -0.12 -0.09 -0.06 -0.03 0.00 0.03 20 30 40 50 60 70 80 90 100 Δ Forward Voltage (Vf) Tc (°C) 6PDS-003157 Rev 01 www.luminus.com
Dominant Wavelength Shift - Red Amber Forward current: ∆λd= λd(If) - λd(0.25 A) Single pulse 20 ms, Tc = 25°C Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.25 A -1.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 20 30 40 50 60 70 80 90 100 Δ Dominant Wavelength (λd) Tc (°C) Peak Wavelength Shift - Red Amber Forward current: ∆λd= λd(If) - λd(0.25 A) Single pulse 20 ms, Tc = 25°C Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.25 A -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 20 30 40 50 60 70 80 90 100 Δ Peak Wavelength (λp) Tc (°C) 7PDS-003157 Rev 01 www.luminus.com
Relative Radiometric Flux - Blue Forward current: φv/φv(0.25 A) Single pulse 20 ms, Tc = 25°C 50% 100% 150% 200% 250% 300% 350% 400% 450% 500% Relative Radiometric Flux If (A) Temperature: φv/φv(25°C) Single pulse 20 ms, If = 0.25 A 76% 80% 84% 88% 92% 96% 100% 104% 20 30 40 50 60 70 80 90 100 110 120 Relative Radiometric Flux Tc (°C) Forward Voltage Shift - Blue Forward current: Vf = V(If) Single pulse 20 ms, Tc = 25°C -0.40 -0.20 0.00 0.20 0.40 0.60 0.80 1.00 Δ Forward Voltage (Vf) If (A) Temperature: ∆Vf = V(Tc) - V(25°C) Single pulse 20 ms, If = 0.25 A -0.18 -0.15 -0.12 -0.09 -0.06 -0.03 0.00 0.03 20 30 40 50 60 70 80 90 100 110 120 Δ Forward Voltage (Vf) Tc (°C) 8PDS-003157 Rev 01 www.luminus.com
Dominant Wavelength Shift - Blue Forward current: ∆λd= λd(If) - λd(0.25 A) Single pulse 20 ms, Tc = 25°C -5.0 -4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0 3.0 Δ Dominant Wavelength (λd) If (A) Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.25 A -0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 20 30 40 50 60 70 80 90 100 110 120 Δ Dominant Wavelength (λd) Tc (°C) Peak Wavelength Shift - Blue Forward current: ∆λd= λd(If) - λd(0.25 A) Single pulse 20 ms, Tc = 25°C -5.0 -4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0 3.0 Δ Peak Wavelength (λp) If (A) Temperature: ∆λd= λd(Tc) - λd(25°C) Single pulse 20 ms, If = 0.25 A -0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 20 30 40 50 60 70 80 90 100 110 120 Δ Peak Wavelength (λp) Tc (°C) 9PDS-003157 Rev 01 www.luminus.com
Angular Intensity Distribution Angular Distribution and Typical Spectrum Typical Spectrum Iref = f(Φ); Tc = 25°C Φref = f(λ); If = 0.25 A; Tc = 25°C 10PDS-003157 Rev 01 www.luminus.com 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 300 400 500 600 700 800 Relative Intensity Wavelength (nm) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 300 400 500 600 700 800 Relative Intensity Wavelength (nm) Blue Red Amber
11PDS-003157 Rev 01 www.luminus.com SMT Rework Guideline Manual Hotplate Reflow Hot Air Gun Reflow Heating Time < 60 sec Hotplate Temperature < 245°C < 150°C Temperature Time Preheat RT to 150°C 1 - 2.5°C/sec Soak 150°C to 180°C 0.4 - 1°C/sec Reflow 180 to TL + 20°C 3 - 6°C/sec Cool down Peak to below 150°C 3 - 7°C/sec Liquidus Temperature, TL (SAC305 = 220°C) Peak Temperature (235 - 245°C) Time Above Liquidus (45 - 90 sec) 65 -> 200°C, 120 - 250 sec max Note: 1. Product complies to Moisture Sensitivity Level 3 (MSL 3). 2. The numbers in the table are specific to SAC305. Luminus recommends using an SAC305 solder paste with a no-clean flux for RoHS compliant products. 3. During the pick and place process, ensure the pick-up tool does not touch any die components. 4. Use of a multi-zone IR reflow oven with a nitrogen blanket is recommended. 5. Time-temperature profile of the reflow process showing the four functional profile zones are defined in IPC-7801. Temperature is referenced to the center of the PCB. 6. Luminus recommends to use the solder paste data sheet information as a starting point in time-temperature process development. 7. These are general guidelines. Consult the solder paste manufacturer’s datasheet for guidelines specific to the alloy and flux combination used in your application. For more information, please refer to: https://luminusdevices.zendesk.com/hc/en-us/articles/360060306692-How-do-I-Reflow-Solder-Luminus-SMD-Components- 8. For any technical questions about soldering process, please contact Luminus at techsupport@luminus.com.
12PDS-003157 Rev 01 www.luminus.com 3.00±0.20 .118±.008 3.00±0.20 .118±.008 0.76 .030 RED DIE EMITTING AREA 0.75 .030 BLUE DIE EMITTING AREA 1.67 .066 0.46 .018 EMITTING AREA A B 0.75 .030 0.50 .020 0.50 .020 0.60 .024 0.54 .021 0.70 .028 2.64 .104 2.55 .100 T B B 0.65 .026 0.44 .017 TOP OF EMISSION TO BACK OF SUBSTRATE C REVISIONS ECO REV. DESCRIPTION DATE APPROVED A INSTIAL DRAWING 06/08/2022 PAD ASSIGNMENTS P1 ANODE (BLUE) N1 CATHODE (BLUE) P2 ANODE (RED) N2 CATHODE (RED) T THERMAL PAD D C B AA B C D 12345678 8 7 6 5 4 3 2 1 .XX = 0.050mm SFM-03X-PICO X.XIE
1145 SONORA COURT
SUNNYVALE, CA 94086 408-708-7000 DESCRIPTION: B UNLESS OTHERWISE SPECIFIED TOLERANCES ARE MILLIMETERS [INCHES] This document and its contents are confidential information of Luminus Devices, Inc. Copyright 2005 Luminus Device,Inc. All rights reserved. B SCALE: ENGINEER: NUMBER:DRAFTER: SIZE: REV:1 OF 3DIMENSIONS ARE IN (UNLESS OTHERWISE SPECIFIED): SHEET: ANGLES 1 PROPRIETARY AND CONFIDENTIAL 3.00±0.20 .118±.008 3.00±0.20 .118±.008 0.76 .030 RED DIE EMITTING AREA 0.75 .030 BLUE DIE EMITTING AREA 1.67 .066 0.46 .018 EMITTING AREA A B 0.75 .030 0.50 .020 0.50 .020 0.60 .024 0.54 .021 0.70 .028 2.64 .104 2.55 .100 T B B 0.65 .026 0.44 .017 TOP OF EMISSION TO BACK OF SUBSTRATE C REVISIONS ECO REV. DESCRIPTION DATE APPROVED A INSTIAL DRAWING 06/08/2022 PAD ASSIGNMENTS P1 ANODE (BLUE) N1 CATHODE (BLUE) P2 ANODE (RED) N2 CATHODE (RED) T THERMAL PAD D C B AA B C D 12345678 8 7 6 5 4 3 2 1 .XX = 0.050mm SFM-03X-PICO X.XIE SUNNYVALE, CA 94086 408-708-7000 DESCRIPTION: B UNLESS OTHERWISE SPECIFIED TOLERANCES ARE MILLIMETERS [INCHES] This document and its contents are confidential information of Luminus Devices, Inc. Copyright 2005 Luminus Device,Inc. All rights reserved. B SCALE: ENGINEER: NUMBER:DRAFTER: SIZE: REV:1 OF 3DIMENSIONS ARE IN (UNLESS OTHERWISE SPECIFIED): SHEET: ANGLES 1 PROPRIETARY AND CONFIDENTIAL 0.65 .026 2X 0.50 .020 2X 0.64 .025 4X 0.40 .016 2X 2.53 .100 2X 0.54 .021 2X 0.54 .021 2X 0.07 .003 1.28 .050 2X 0.45 .018 2X 0.56 .022 2X 0.44 .017 2X 0.04 .002 RECOMMENDED STENCIL PATTERN * TOLERANCE UNLESS MENTIONED IS 0.1mm. ANODE (BLUE) P1 CATHODE (BLUE)N1 ELECTRICL CIRCUIT CATHODE (RED)N1 ANODE (RED) P1 D C B AA B C D 12345678 8 7 6 5 4 3 2 1 NONE SFM-03X-SAPPGIRE X.XIE SUNNYVALE, CA 94086 408-708-7000 DESCRIPTION: AMILLIMETERS [INCHES] B SCALE: ENGINEER: NUMBER:DRAFTER: SIZE: REV:2 OF 3DIMENSIONS ARE IN (UNLESS OTHERWISE SPECIFIED): SHEET: 0.65 .026 2X 0.50 .020 2X 0.64 .025 4X 0.40 .016 2X 2.53 .100 2X 0.54 .021 2X 0.54 .021 2X 0.07 .003 1.28 .050 2X 0.45 .018 2X 0.56 .022 2X 0.44 .017 2X 0.04 .002 RECOMMENDED STENCIL PATTERN * TOLERANCE UNLESS MENTIONED IS 0.1mm. ANODE (BLUE) P1 CATHODE (BLUE)N1 ELECTRICL CIRCUIT CATHODE (RED)N1 ANODE (RED) P1 D C B AA B C D 12345678 8 7 6 5 4 3 2 1 NONE SFM-03X-SAPPGIRE X.XIE SUNNYVALE, CA 94086 408-708-7000 DESCRIPTION: AMILLIMETERS [INCHES] B SCALE: ENGINEER: NUMBER:DRAFTER: SIZE: REV:2 OF 3DIMENSIONS ARE IN (UNLESS OTHERWISE SPECIFIED): SHEET:
13PDS-003157 Rev 01 www.luminus.com 图纸编号:K036200 P0 P2 D0 EF W K0B0 T SYMBOL A0 B0 K0 P0 P1 P2 SYMBOL T E F D0 D1 W ToleranceUsage drawer checker date name Scale: 1:1 Weight: Part No.: page replace for replace bysourcechange date name K074113(3032-0.60) 2020-1-13 ZN D1P1 Ruizai Version A B C D E F G H NOTE: A.10个连续孔的累计偏差不得超过0.2mm B.每250mm载带的弯曲度不得超过1mm C.所有的尺寸都要符合EIA-481-D的要求 D.K0的尺寸为型腔内底部到载带上表面距离 E.材料:黑色,导电ECM3 F.A0&B0的测量位置在载带型腔最底部. P0 P2 D0 EF W K0B0 T SYMBOL A0 B0 K0 P0 P1 P2 SYMBOL T E F D0 D1 W ToleranceUsage drawer checker date name Scale: 1:1 Weight: Part No.: page replace for replace bysourcechange date name K074113(3032-0.60) 2020-1-13 ZN D1P1 Ruizai Version A B C D E F G H NOTE: A.10个连续孔的累计偏差不得超过0.2mm B.每250mm载带的弯曲度不得超过1mm C.所有的尺寸都要符合EIA-481-D的要求 D.K0的尺寸为型腔内底部到载带上表面距离 E.材料:黑色,导电ECM3 F.A0&B0的测量位置在载带型腔最底部. Parameter Dimension (mm) A0 3.20+/-0.10 B0 3.40+/-0.10 K0 0.85+/-0.10 P0 4.00+/-0.10 P1 4.00+/-0.10 P2 2.00+/-0.10 T 0.20+/-0.05 E 1.75+/-0.10 F 3.50+/-0.10 D0 1.55+/-0.05 D1 1.10+/-0.05 W 8.00+/-0.10 Note: Minimum order quantity: 500 pieces. Parameter Dimension (mm) A 179.0+/-1.0 B 60.5+/-0.5 C 11.8+/-0.3 D 9.2+2.0 9.2-0.3 E 13.5+/-0.2 F 10.0+/-0.2 T1 1.0+/-0.2 T2 1.6+/-0.2
Label Fields:
- CPN: Luminus ordering part number
- CID: Customer’s part number
- QTY: Quantity of devices in pack
- Flux: Bin as defined on page 3
- Voltage: NA
- Color: NA
- CRI: NA
- Lot ID: For Luminus internal use
- Reel ID: For Luminus internal use Packing Configuration:
- Maximum of 500 devices per reel
- Partial reel may be shipped
- Each pack is enclosed in anti-static bag
- Shipping label is placed on top of each pack XXX-XX-XXXX-XXXX-XXXXXXXXX 500 Reel ID 14PDS-003157 Rev 01 www.luminus.com
This product is sensitive to static electricity, and care should be taken when handling them. Static electricity or surge voltage will damage the LEDs. It is recommended to wear an anti-electrostatic wristband or anti-electrostatic gloves when handling the LEDs. All devices, equipment and machinery must be properly grounded. It is recommended that measures be taken to isolate LED processing equipment from potential sources of voltage surges. Reference: APN-002815 Electrical Stress Damage to LEDs and How to Prevent It Eye Safety According to the test specification risk group IEC 62471-Non-GLS under 0.25 A, this product complies to Risk group 2 (RG2) Moderate risk. Do not stare at operating lamp, may be harmful to the eyes. For more information, please refer to: https://luminusdevices.zendesk.com/hc/en-us/articles/10532958752397 15PDS-003157 Rev 01 www.luminus.com
Revision History
Rev Date Description of Change 01 03/18/2024 Initial release SFM-03X-RAB Product Datasheet 16PDS-003157 Rev 01 www.luminus.com