NDS1.1334 - Page 1 / 2

Document overview

  • PDF pages: 2

Technical content

NDS1.1334 - Page 1 / 2 Product Datasheet SFD2-10-100-275-A Two Phase DIN Mount Surge Filters The Novaris SFD2 range of surge Ölters is designed for protecting ×oating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems. Multistage Protection. The SFD2 uses 3 stages of protection to provide a low let through voltage. The Örst stage comprises a delta conÖguration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass Ölter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges. No Earth Leakage. The SFD2 conÖguration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth. Safe Metal Enclosure. Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch Öre or explode. Installation Independent Performance. Series surge protectors such as the SSP and SFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations. Wiring Dimensions Standards IEC 61643-11:2011 SPD connected to low-voltage power systems - Type 2+3 AS/NZS 1768:2007 A.C. power system SPD - Cat C, B, A UL 1449 3rd edition Low voltage SPD - Type 2, 3 IEEE 62.41.2:2002 Low voltage SPD - Cat B  72 Browns Road, Kingston Tasmania 7050 Australia

NDS1.1334 - Page 2 / 2 Product Datasheet Specications Electrical Specications Connection type 1 Series Modes of protection 2 L-L, L-PE Number of phases 3 2 Nominal voltage 4 230VAC Maximum load current 10A Electrical (L-L) Specications Maximum continuous voltage AC 8 275VAC Maximum continuous voltage DC 8 350VDC Maximum discharge current (8/20 μ s) 9 100kA Nominal discharge current (8/20 μ s) 0 40kA Voltage protection level (3kA 8/20 μ s) q <600V Electrical (L-PE) Specications Maximum discharge current (8/20 μ s) 9 40kA Nominal discharge current (8/20 μ s) 0 40kA Voltage protection level (1kV/ μ s) q <700V Response time w <100ns Voltage protection level (In) q <1000V Indication Specications Display t LED thermal failure Alarm y Passive alarm Alarm isolation u 4kV Mechanical Specications Minimum operating temperature g -40°C Maximum operating temperature h 70°C Minimum operating humidity k 5% Maximum operating humidity j 95% Mounting method a TS35 DIN Rail Environmental rating f IP20 Enclosure material s Aluminium Enclosure nish d Black powdercoat Length l 95mm Width ; 118mm Height z 69mm Other Specications Product Code x SFD2-10-100-275-A Shipping Specications Weight v 850g Customs tariff b 85354010  72 Browns Road, Kingston Tasmania 7050 Australia