High Voltage DC Relay SEV10 Version:V1.1 10A 1000MΩ(1000VDC) ≤10mΩ(@6V 20A) 3000VAC 1min. 10mA 4000VAC 1min. 10mA12VDC 0.5A 1000VDC ≤30ms ≤10ms 196m/s (20G) 490m/s (50G) 10Hz~500Hz 49m/s (5G)1× cycles5 (10A,500VDC) 5 10× cycles ( 10A,500VDC)- 5 10× cycles ( 10A,750VDC)- 7.5 10× cycles (10A,1000VDC) 3 10× cycles (-10A,1000VDC) 1 10× cycles (10A,750VDC) 100A,1000VDC,1cycle 5× cycles5 500V type 750V type 10KW -40℃~85℃ 5%~95% RH Approx.185g 66.8×44.5×36.85 10A:continuity 15A:1h 20A:20min. 40A:30s 60A:10s 100A:0.6s 12 24 ≤9 ≤18 ≥1.0 ≥2.0 48 192 3 3 3 3 Relays for advanced technology SANYOURELAYS Feature
- 10 amps continuous carry,100 amps interrupte under extreme condition.
- Hermetically sealed with hydrogen gas,the arc is not exposed. Be able to use in explosive & harsh environments without oxidation contamination contacts.Contacts' part meet or of IP67 protection degree.
- -Not position sensitive can be mounted in any position for ease of installation.
- o compliant.R HS Contact Data Item Information Contact arrangement 1 Form A contact Current rating Contact resistance Min.Switching load Max. Switching voltage Max. Breaking current Max. Switching power Electrical (1) life Resistive load Load current (2) capacity NOTES: (1)Ambient temperature:23℃,L/R≤1ms. (2)Ambient temperature:23℃,4mm conductor. (3)Other types of rated voltage,please contact us. Parameters Table Item Information Mechanical life Insulation resistance Dielectric strength Between open contacts Between contact and coil Operate time (at rated coil voltage) Release time (at rated coil voltage) Shock resistance Functional Destructive Vibration resistance Ambient temperature Ambient humidity Weight External dimension (3) Coil Data Rated voltage(VDC) Operation voltage(VDC) Max. voltage(VDC) Pick-up voltage(VDC) Drop-out voltage(VDC) Coil resistance(±10%)(Ω) Operating power (inrush,W) Operating power (stable,W)
SEV 10 - □ M □ □ Type designation SEV Load current 10:10A Contact arrangement M:1 Form A Coil voltage 12:12VDC 24:24VDC Customer special code Nil:No customer special requirement Numbers or Letters:Customer special requirement Voltage rating 750:12~750VDC 500:12~500VDC Packing quantity:1pcs inner carton, 60pcs outer carton
Ordering Information
Less than 10mm: ±0.3 10 to 50mm: ±0.5 More than 50mm: ±0.8
Installation Size Chart Schematic Diagram NOTE:The contacts are polarizedNOTES
- Mounting Attention 1.When installing the relay, always use washers to prevent the screws from loosening. 2.Tighten each screw within the rated range given in the . Exceeding outline dimensions the maximum torque may result in breakage. 3.Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or close to an object that radiates heat.
- Electrical Life Attention 1.This relay is a DC high-voltage switch. In its final breakdown mode, it may lose the ability to provide the proper cut-off.Therefore, do not exceed the indicated switching capacity and life. 2.Please treat the relay as a product with limited life and replace it when necessary. 3.The contacts of the relay are polarized. Please follow instructions in the connection schematic when connecting the contacts. 4.Be careful that foreign matter and oils and fats kind, don’t stick to the main terminal parts because it is likely to cause terminal parts to give off unusual heat. Also, please use the following specifications of conductor. 10A Min. 2mm nominal cross-sectional area 20A Min. 3mm nominal cross-sectional area 40A Min. 10mm nominal cross-sectional area 60A Min. 15mm nominal cross-sectional area 100A Min. 35mm nominal cross-sectional area 150A Min. 45mm nominal cross-sectional area 200A Min. 60mm nominal cross-sectional area 250A Min. 80mm nominal cross-sectional area 300A Min. 100mm nominal cross-sectional area
- Coil Attention 1.Please note that when using a diode, the switching speed may decrease and cause a reduction in cut-off performance, we recommend installing a surge protector varistor. 2.The pick-up voltage and drop-out voltage will change with ambient temperature, please use rated voltage to make sure the relay operate reliable. Don’t exceed maximum coil voltage. 3.The 250A and 300A types have built-in dedicated drive circuit, please drive the coil with a quick startup (Built-in one-shot pulse generator circuit). 4.After the ON signal enters the 250A and 300A types, automatic coil current switching occurs after approximately 0.1 seconds.Do not repeatedly turn it OFF within that 0.1 seconds interval, as doing so may damage the relay. Disclaimer: This datasheet is the customers’reference. All the specification are subject to change without notice. We could not evaluate all the performance and parameters for every possible application. Thus the users should be in a right position to choose the suitable product for their own application. If there is any query, please contact Sanyou for technical service. However it is the users' responsibility to determine which product should be used only. SANYOU CORPORATION LIMITED. All rights reserved by Sanyou.