SET40 SANYOU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Features

SANYOU RELAYSRelays for advanced technology Large Power Relay AC2,000V,50/60Hz 1min. 40A 250VAC 30,000 version:V1.1 applying Environment friendly product(Compliant with RoHS) Nominal operating current ±10% (mA) Coil resistance ±10% (Ω) Max. allowable voltage Pick-up voltage (Max.) Drop-out voltage (Min.) Nominal operating power Nominal voltage (VDC) Coil Data (at 20℃) 100 638.30 319.15 160.00 80.00 40.00 19.23 4.7 18.8 300 1200 5200 110% of 80 % of 10 % of Approx. 1.90W 4KV dielectric between coil and contact Have 2 groups of Normal open contacts Strong load capacity 3mm contacts gap for safty design UL insulation: Class F insulation is available AC2,000V,50/60Hz 1min.Between contact sets: 110 200 17.26 9.52 6300 21000 Nominal voltage Nominal voltage Nominal voltage

Insulation System:Nil-Standard, B-Class B, F-Class F Contact material:Nil-AgSnO2 Terminal Form: B- screw terminal, T- quick connection terminal, Coil Power:D-DC coil,A-AC coil Number of Poles:2-2 Pole Type Designation:SET40 Special Parameter:Nil-Standard type, Letters or Numbers-Special reqirements SET40 SET40 - 2 12 D B F - F -S -XX Safety Approval Ratings (Note:More detail of approval ratings,please refer to the safety certification)

Ordering Information

Outline Dimensions, Wiring Diagram, P.C. (unit:mm)Board Layout 40A 250VAC 40A 250VAC 40A 250VAC CQC TUV UL/CULVDEApproval File No. Approved ratings Wiring Diagram 18.8 300 1200 5200 20800 18.7/22.1 9.7/10.8 1.7~2.5VA 275.00 138.00 74.00 39.00 Nominal operating current ±10% (mA) Coil resistance ±10% (Ω) Max. allowable voltage Pick-up voltage (Max.) Drop-out voltage (Min.) Nominal operating power Nominal voltage (VAC) applying applying applying applying 40A 250VAC Coil Voltage(VDC):03,06,12,24, 48, 100, 110, 200 Coil Voltage(VAC):06, 12, 24, 48, 120, 220/240 S-with microswitch + wire, S1-with microswitch + connector Cover Form: F- flange cover, Nil-non-flange cover P- PCB terminal SET40-BF P.C.B layout(Bottom view) 110% of 80 % of 10 % of Nominal voltage Nominal voltage Nominal voltage

Unless otherwise specified: If dimension <1mm, tolerance: ±0.2mm; If dimension 1~5mm, tolerance: ±0.3mm; If dimension >5mm, tolerance: ±0.4mm. Note: 1. Extended terminal dimension is dimension before soldering. Wiring Diagram P.C.B layout(Bottom view) Wiring Diagram P.C.B layout(Bottom view)

Wiring Diagram P.C.B layout(Bottom view) Wiring Diagram P.C.B layout(Bottom view)

Contact Current(A) Contact Voltage(V) Max. Switching Power Contact Current(A) Operations(×10000 Ops.) Endurance Curve AC Res. 250VAC Res. Especially suitable for Photovoltaic inverter,UPS,charging pile etc 100 0.5 0.1 10 30 50 100 300 10001 20 200 SET40 100 500 4 8 12 16 20 24 28 32 36 40 30

  • Assembly
  • Installation at dry and less dust place.
  • The PCB terminals'weight is approx. 100g. Pls. mind its strength.
  • Load This relay is used for motor,transformer,spiratron,lamp,heater,etc.
  • Manual soldering, pls. avoid automatic soldering. Sometimes
  • It's not sealed structure which can't be washable.
  • Connection
  • When it's the screw terminals, the terminal space size as reference below.
  • Pls. leave room on wire when wiring. Do not put too much force
  • Fasten torque Coil terminals: 0.98 N.m Contacts terminals: 1.37 N.m
  • Installation torque 0.98N·m
  • Pls. do not put too much force when push and pull plug socket.
  • Pls. avoid connecting the QC terminals by soldering. Note: If use the hole terminal, pls. sure the current is less 30A.
  • Reference data
  • AC100V as standards if the rated voltage is AC100V~120V.
  • Coil operation
  • When it's drived by transistor, pls. sure the electric leakage,
  • There is full-wave rectifier circuit in AC operation coil. If use Cautions Screw terminals Coil terminals side Contacts terminals side <Coil inner circuit drawing>
  • DC operation coil ·AC operation coil SET40 In addition,the heat will cause reduction of welding cracks. So pls. use through hole type board. Pls. don't use for tiny load. flux will stick on the test button which cause NG operation.
  • Soldering on terminals. Also, do it one by one, do not at the same time or at an oblique angle. connect the bleeder resistance if necessary. SSR or bi-directional triode to drive relay which will cause reset NG. Pls. confirm on the actual equipment if it has this situation. Disclaimer: This datasheet is the customers' reference. All the specification are subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application.Thus the user should in a right position to choose the suitable product for their own application.If there is any query, please contact Sanyou for the technical service.However it is the user's responsibility to determine which product should be used only. Sanyou Corporation Limited ,All rights of Sanyou to reserved