S030 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 22

Technical content

Visit product website  DATA SHEET Type SE30  Transmitter for Inline sensor-fitting Type SE32  Transmitter for Inline sensor-fitting Type SE35  Transmitter or batch controller for Inline sensor-fitting Type SE36  ELEMENT transmitter for Inline sensor fitting Type 8611  eCONTROL - Universal controller Standard | EU | en | 2024-01-15 | 24 Inline sensor-fitting with paddle wheel for flow measure- ment

  • DN 06 to DN 65 Wide range of materials and type of process connections available to ideally fit to the individual applications and process conditions Closed pipe system, sensor inside fitting Quarter-turn technology Transmitter available for indication, monitoring, transmitting, On/Off control or batch control The sensor-fitting Type S030 has a built-in paddle wheel to measure the flow rate and is especially designed for use with neutral, slightly aggressive, solid free liq uids. The compact sensor-fitting (Type S030) must be equipped with a Bürkert transmit- ter (Type SE30, SE30 Ex, SE32, SE35, SE36 or 8611) quickly and easily connected together by a bayonet catch. The Bürkert “Inline quarter-turn” technology is a con- struction ensuring a leakage free operation. The paddle wheel rotation (permanent magnets included in the blades) is detected contactless by the sensitive element of the transmitter through the sensor-fitting wall. The transmitter can be fitted and removed without opening the pipe or inter- rupting the running process. Product variants described in the data sheet may differ from the product presentation and description. Type description Can be combined with Type S030 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 22Visit product website  Table of contents 1. General technical data 4 Approvals and conformities 2.2. Conformity ... 2.3. Standards .... 2.4. Pressure Equipment Directive (PED) .... Device used on a pipe 2.5. Foods and beverages/Hygiene ... 3. Materials 7 3.2. Material specifications ... 4. Dimensions 8 Internal thread connection External thread connection Weld spigot connection Clamp connection 4.2. Plastic sensor-fitting True union connection with nut and solvent/fusion socket External thread connection Solvent/fusion spigot connection 5. Performance specifications 13 With sensor-fitting S030 standard With sensor-fitting S030-HT 6. Product installation 14 Flow measurement 6.2. Selection of the nominal diameter ... 7. Product operation 15 8. Product design and assembly 16 9. Product accessories 16 10. Networking and combination with other Bürkert products 11.

Ordering information

11.2. Recommendation regarding product selection.... 11.3. Bürkert product filter 11.4. Ordering chart

3 | 22Visit product website  Plastic sensor-fitting Stainless steel sensor-fitting (S030-HT variant) 11.5. Ordering chart accessories ....

4 | 22Visit product website  1. General technical data Note: In the range of sensor fittings, there are specific ones for the measurement of flow rates at high temperature and pressure. These are the S030-HT models, which can only be used with the SE30 transmitter in the high temperature variant (SE30-HT). Product properties Material Make sure the device materials are compatible with the fluid you are using. Further information can be found in chapter “3.1. Bürkert resistApp” on page 7 Further information on the materials can be found in chapter “3.2. Material specifications” on page Non wetted parts Screw Stainless steel (316L 1.4404) Wetted parts Body, sensor armature Stainless steel (316L 1.4404), brass (CuZn39Pb2), PVC, PP or PVDF (depending on the sensor fitting variant Type S030) Axis Ceramics (Al2O3) Bearing • Ceramics (Al2O3) Iglidur® (only for Type S030-HT variant) Paddle wheel • PVDF Stainless steel (316L 1.4404) (only for Type S030-HT variant) PP on request Sensor-fitting body Stainless steel (316L 1.4404), brass (CuZn39Pb2), PVC, PP or PVDF (depending on the sensor fitting variant Type S030) Seal FKM or EPDM (depending on the sensor fitting variant Type S030) Further information can be found in chapter “11.5. Ordering chart accessories” on page 21 Compatibility • Bürkert flow transmitter Type SE30, SE30 Ex, SE32, SE35, SE36, batch controller SE35 or 8611 Universal controller Bürkert flow transmitter Type SE30-HT (only for Type S030-HT variant) Pipe diameter DN 06…DN Dimensions Further information can be found in chapter “4. Dimensions” on page 8 Measuring principle Paddle wheel Measuring range Flow rate: 0.5…1200 l/min (0.13…317 gpm) Performance data Measurement deviation • Teach-In (via a remote transmitter): ± % of the measured value 1.) at teach flow rate value Standard K factor: ± 2.5 % of the measured value 1.) Linearity ± 0.5 % of full scale 1.) Repeatability ± 0.4 % of the measured value 1.) Medium data Fluid Clean, neutral or slightly aggressive, solid-free liquids Fluid temperature For sensor-fitting in: PVC: 0…+ °C (+ 32…+ 122 °F) PP: 0…+ °C (+ 32…+ 176 °F) PVDF, stainless steel or brass: - 15…+ 100 °C (+ 5…+ 212 °F) stainless steel (Type S030-HT variant): - 15…+ 125 °C (+ 5…+ 257 °F) Fluid pressure For sensor-fitting in: plastic: max. PN metal: max. PN stainless steel (Type S030-HT variant): max. PN 40 (for - 15…+ °C (+ 5…+ 194 °F) temperature range) max. PN 25 (for + 90…+ 125 °C (+ 194…+ 257 °F) temperature range) Further information can be found in chapter “5.1. Pressure temperature diagram” on page 13 Viscosity Max. 300 cSt. Rate of solid particles Max. 1 Maximum particle size 0.5 mm Flow velocity • 0.3…10 m/s 0.5…10 m/s (only for Type S030-HT variant) Further information can be found in chapter “6.2. Selection of the nominal diameter” on page 15

5 | 22Visit product website  Process/Pipe connection & communication Measuring devices connection Bürkert bayonet catch Pipe connection For sensor-fitting in: plastic: true union with nut and solvent/fusion socket, spigot or external thread metal: internal or external thread, weld ends, clamp or flange stainless (Type S030-HT variant): internal or external thread, weld ends (clamp or flange on request) Approvals and conformities Directives CE directive Further information on the CE directive can be found in chapter “2.3. Standards” on page 6 Pressure equipment directive Complying with article 4, paragraph 1 of 2014/68/EU directive Further information on the pressure equipment directive can be found in chapter “2.4. Pressure Equipment Directive (PED)” on page 6 Foods and beverages/Hygiene FDA declaration of conformity (stainless steel fitting only with EPDM seal) Must be ordered separately. Further information can be found in chapter “Accessories for all variants” on page 25 Materials • Inspection certificate 3.1 (according to EN-ISO 10204) Certification of conformity for the surface finish (according to DIN4762, DIN4768, ISO/4287/1) Must be ordered separately. Further information can be found in chapter “Accessories for all variants” on page 25 Others • points flow calibration certificate Test report 2.2 (according to EN-ISO 10204) Must be ordered separately. Further information can be found in chapter “Accessories for all variants” on page 25 Environment and installation Ambient temperature Operation and storage: for sensor-fitting in PVC: - 15…+ °C (+ 5…+ 122 °F) PP: - 15…+ °C (+ 5…+ 176 °F) PVDF, stainless steel or brass: - 15…+ 100 °C (+ 5…+ 212 °F) The temperature limits also depend on the used transmitter, see the relevant data sheet or operating instructions for more information. 1.) Under reference conditions i.e. measuring medium = water, ambient and water temperature = + 20 °C (+ 68 °F), observing the minimum the minimum inlet and outlet sections and the appropriate inner diameter of the pipe.

6 | 22Visit product website  2. Approvals and conformities 2.1. General notes

  • The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available variants of the device can be supplied with t he below mentioned approvals or conformities. 2.2. Conformity In accordance with the Declaration of Conformity, the product is compliant with the EU Directives. 2.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 2.4. Pressure Equipment Directive (PED) The device conforms to article 4, paragraph 1 of the Pressure Equipment Directive (PED) 2014/68/EU under the following conditions: Device used on a pipe Note: The data in the table is independent of the chemical compatibil ity of the material and the fluid. PS = maximum admissible pressure (in bar), DN = nominal diameter of the pipe Type of fluid Conditions Fluid group 1, article 4, paragraph 1.c.i DN ≤ 25 Fluid group 2, article 4, paragraph 1.c.i DN ≤ 32 or PS*DN ≤ 1000 Fluid group 1, article 4, paragraph 1.c.ii DN ≤ 25 or PS*DN ≤ 2000 Fluid group 2, article 4, paragraph 1.c.ii DN ≤ 200 or PS ≤ 10 or PS*DN ≤ 5000 2.5. Foods and beverages/Hygiene Note: The specific sensor fittings (S030-HT) for the measurement of flow rates at high temperature and pressure is not covered by this certificat. Conformity Description FDA FDA – Code of Federal Regulations (valid for the variable code PL02, PL03) The variants with the body and the sensor armature made of PVDF or stainless steel materials, the paddle wheel made of PVDF material and the seal made of FKM or EPDM materials are compliant in their composition with the Code of Federal Regulations published by the FDA (Food and Drug Administration, USA) according to the manufac- turer‘s declaration.

7 | 22Visit product website  3. Materials 3.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check 3.2. Material specifications Note: The following picture describes the sensor-fitting with a process true union connection with nut and solvent/fusion socket, but this also applies to all variants of process connection. No. Element Material

1 Sensor armature Stainless steel

2 Screws Stainless steel

3 Axis and bearings •

Axis in ceramics (Al2O3) Bearings in: ceramics (Al2O3) Iglidur® (only for Type S030-HT variant)

4 Paddle wheel •

Stainless steel (only for Type S030-HT variant)

5 Seal FKM or EPDM (depending on Type

S030 variant)

6 Sensor-fitting body •

Stainless steel (316L 1.4404), brass (CuZn39Pb2), PVC, PP, PVDF (depending on the sensor-fitting variant Type S030) Stainless steel (316L 1.4404) (only for Type S030-HT)

7 Seals FKM or EPDM (depending on the sensor-fitting variant Type

S030 and only for true union connection with nut and solvent/fusion socket)

8 | 22Visit product website  4. Dimensions 4.1. Metal sensor-fitting Internal thread connection Note: Dimensions in mm, unless otherwise stated G, NPT or Rc in stainless steel (316L 1.4404) or brass (CuZn39Pb2) L D P DN P L L1 D [inch] 15 34.5 84.0 16.0 G

17.0 NPT

15.0 Rc 20 32.0 94.0 17.0 G

18.3 NPT

16.3 Rc 25 32.2 104.0 23.5 G

18.0 NPT

18.0 Rc 32 35.8 119.0 23.5 G

21.0 NPT

21.0 Rc 40 39.6 129.0 23.5 G

20.0 NPT

19.0 Rc 50 45.7 148.5 27.5 G

24.0 NPT

24.0 Rc External thread connection Note: Dimensions in mm, unless otherwise stated G, NPT or Rc in stainless steel (316L 1.4404) or brass (CuZn39Pb2) L D P DN P L L1 D [inch] 06 29.5 90.0 14.0 G 08 29.5 90.0 14.0 G, NPT or Rc 15 34.5 84.0 11.5 G 20 32.0 94.0 13.5 G 25 32.2 104.0 14.0 G 32 35.8 119.0 18.0 G SMS 1145 in stainless steel (316L 1.4404) L D P DN P L D 25 32.0 130 Rd 40 x ¹∕₆" 40 35.8 164 Rd 60 x ¹∕₆" 50 39.6 173 Rd 70 x ¹∕₆"

9 | 22Visit product website  Weld spigot connection Note: Dimensions in mm, unless otherwise stated EN ISO 1127/ISO 4200/DIN 11866 series B, SMS 3008, BS 4825 1/ASME BPE/DIN 11866 series C or DIN 11850 series 2/DIN 11866 series A/ DIN EN 10357 series A in stainless steel (316L 1.4404) L ∅ D P e DN P Standard L Ø D e 08 – EN ISO 1127/ISO 4200/DIN 11866 series B – – – – SMS 3008 – – – – ASME BPE/DIN 11866 series C – – –

29.5 DIN

A 96.0 13.00 1.50 15 34.5 EN ISO 1127/ISO 4200/DIN 11866 series B 84.0 21.30 1.60 – SMS 3008 – – – – ASME BPE/DIN 11866 series C – – –

34.5 DIN

A 84.0 19.0 1.50 20 32.0 EN ISO 1127/ISO 4200/DIN 11866 series B 94.0 26.9 1.60 – SMS 3008 – – –

34.5 ASME BPE/DIN

C 84.0 19.05 1.65 A 84.0 23.00 1.50 25 32.2 EN ISO 1127/ISO 4200/DIN 11866 series B 104.0 33.70 2.00 32.0 SMS 3008 94.0 25.00 1.20

32.0 BS 4825

C 94.0 25.40 1.65

32.0 DIN

A 94.0 29.00 1.50 32 35.8 EN ISO 1127/ISO 4200/DIN 11866 series B 119.0 42.40 2.00 – SMS 3008 – – –

32.2 BS 4825

C 104.0 32.00 1.65

32.2 DIN

A 104.0 35.00 1.50 40 39.6 EN ISO 1127/ISO 4200/DIN 11866 series B 129.0 48.30 2.00 35.8 SMS 3008 119.0 38.00 1.20

35.8 BS 4825

C 119.0 38.10 1.65

35.8 DIN

A 119.0 41.00 1.50 50 45.7 EN ISO 1127/ISO 4200/DIN 11866 series B 148.5 60.30 2.60 39.6 SMS 3008 128.0 51.00 1.20

39.6 BS 4825

C 128.0 50.80 1.65

39.6 DIN

A 128.0 53.00 1.50 65 – EN ISO 1127/ISO 4200/DIN 11866 series B – – – 45.7 SMS 3008 147.0 63.50 1.60

45.7 BS 4825

C 147.0 63.50 1.65 – DIN 11850 series 2/DIN 11866 series DIN EN 10357 series A – – –

10 | 22Visit product website  Clamp connection Note: Dimensions in mm, unless otherwise stated DIN 32676 series B, SMS 3017 1.), BS 4825-3/ASME BPE 1.) or DIN 32676 series A in stainless steel (316L - 1.4404) ∅ D P L ∅ D1 ∅ D2 ∅ D3 DN P Standard L Ø D Ø D1 Ø D2 Ø D3 08 – DIN 32676 series B

29.5 DIN 32676 series

A 125 34.0 27.5 13.00 10.00 15 34.5 DIN 32676 series B A 119 34.0 27.5 19.00 16.00 20 32.0 DIN 32676 series B 150 50.5 43.5 26.90 23.70

34.5 DIN 32676 series

A 119 34.0 27.5 23.00 20.00 25 32.2 DIN 32676 series B 160 50.5 43.5 33.70 29.70 3/ASME BPE 129 50.5 43.5 25.40 22.10

32.0 DIN 32676 series

A 136 50.5 43.5 29.00 26.00 32 35.8 DIN 32676 series B 180 50.5 43.5 42.40 38.40 – BS 4825 – DIN 32676 series 40 39.6 DIN 32676 series B 200 64.0 56.5 48.30 44.30 3/ASME BPE 161 50.5 43.5 38.10 34.80

35.8 DIN 32676 series

A 161 50.5 43.5 41.00 38.00 50 45.7 DIN 32676 series B 230 77.5 70.5 60.30 55.10 3/ASME BPE 192 64.0 56.5 50.80 47.50

39.6 DIN 32676 series

A 170 64.0 56.5 53.00 50.00 65 – DIN 32676 series 3/ASME BPE 216 77.5 70.5 63.50 60.2 – DIN 32676 series 1.) Available with internal surface finish Ra < 0.8 µm 2.) Similar to DIN 32676 series B, but with 34.0 mm clamp connection

11 | 22Visit product website  Flange connection Note: Dimensions in mm, unless otherwise stated EN1092 1/B1/PN 16, ANSI B16 - 5 or JIS 10 K in stainless steel (316L 1.4404) L P ∅ D2 ∅ D1 ∅ D ∅ J DN P Standard L L1 Ø D Ø D1 Ø D2 Ø J 14.0 ANSI 130 89.0 60.3 34.9 4 15.8 JIS 152 95.0 70.0 51.0 4 15.0 14.0 ANSI 150 99.0 69.8 42.9 4 15.8 JIS 178 100.0 75.0 56.0 4 15.0 14.0 ANSI 160 108.0 79.4 50.8 4 15.8 JIS 216 125.0 90.0 67.0 4 19.0 18.0 ANSI 180 117.0 88.9 63.5 4 15.8 JIS 229 135.0 100.0 76.0 4 19.0 18.0 ANSI 200 127.0 98.4 73.0 4 15.8 JIS 241 140.0 105.0 81.0 4 19.0 18.0 ANSI 230 152.0 120.6 92.1 4 19.0 JIS 267 155.0 120.0 96.0 4 19.0 4.2. Plastic sensor-fitting True union connection with nut and solvent/fusion socket Note: Dimensions in mm, unless otherwise stated DIN 8063, ASTM D 1785/76 or JIS K in PVC DIN 16962 in PP or ISO 10931 in PVDF ∅ D ∅ D1 L P DN P Standard L L1 L2 Ø D Ø D1 1.) 29.5 DIN/ISO 122.0 92 90 12.00 – 15 34.5 DIN/ISO 128.0 96 90 20.00 43 ASTM 130.0 21.30 JIS 129.0 18.40 20 32.0 DIN/ISO 144.0 106 100 25.00 53 ASTM 145.6 26.70 JIS 145.0 26.45 25 32.2 DIN/ISO 160.0 116 110 32.00 60 ASTM 161.4 33.40 JIS 161.0 32.55 32 35.8 DIN/ISO 168.0 116 110 40.00 74 ASTM 170.0 42.20 JIS 169.0 38.60 40 39.6 DIN/ISO 188.0 127 120 50.00 83 ASTM 190.2 48.30 JIS 190.0 48.70 50 45.7 DIN/ISO 212.0 136 130 63.00 103 ASTM 213.6 60.30 JIS 213.0 60.80 1.) Only available in PVC

12 | 22Visit product website  External thread connection Note: Dimensions in mm, unless otherwise stated G, NPT or Rc in PVC (only DN 06 and DN 08) or PVDF (only DN 08) L D P DN P L L1 D [inch] 06 29.5 90.0 14.0 G 08 29.5 90.0 14.0 G, NPT or Rc Solvent/fusion spigot connection Note: Dimensions in mm, unless otherwise stated DIN 8063 in PVC, DIN 16962 in PP or ISO 10931 in PVDF L PH ∅ D DN P Standard H L L1 Ø D 15 34.5 DIN 8063 17.5 90 16.5 20 DIN 16962 85 14.0 DIN 10931 85 14.0 20 32.0 DIN 8063 17.5 100 20.0 25 DIN 16962 92 16.0 DIN 10931 92 16.0 25 32.2 DIN 8063 21.5 110 23.0 32 DIN 16962 95 18.0 DIN 10931 95 18.0 32 35.8 DIN 8063 27.5 110 27.5 40 DIN 16962 100 20.0 DIN 10931 100 20.0 40 39.6 DIN 8063 31.5 120 30.0 50 DIN 16962 106 23.0 DIN 10931 106 23.0 50 45.7 DIN 8063 39.5 130 37.0 63 DIN 16962 110 27.0 DIN 10931 110 27.0

13 | 22Visit product website  5. Performance specifications 5.1. Pressure temperature diagram With sensor-fitting S030 standard -20 0 20 40 60 80 PVDF PVC PP Metal Application range for comp lete device (senso r-fitting Type S030 + transmitter Type SE30, SE32, SE35, SE36 or 8611 ) Fluid temperature °C Pressure (bar) 100 Application range for comp lete device (senso r-fitting Type S030 + transmitter Type SE30 Ex) With sensor-fitting S030-HT -20 0 20 40 60 80 100 Stainless steel Fluid temperature °C Pressure (bar) Application range for flowme ter Type 8030-HT (Inline senso r-fitting Type S030-HT + transmitter Type SE30-HT) 125

14 | 22Visit product website  6. Product installation 6.1. Installation notes Flow measurement Note: The device is not suitable for use in gaseous media and steam. Minimum straight distances upstream and downstream of the sensor must be observed. These stabilizing distances depend on the pipe’s design. Increasing these distances or installing a flow conditioner may be necessary to obtain the best accuracy. For more information, refer to EN ISO 5167 EN ISO 5167 1 specifies the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve calm flow conditions. The most commonly used elements that could lead to turbulence in the flow are shown below. The related minimum inlet and outlet distances that ensure a calm flow are also specified. Make sure that the measuring conditions at the point of measurement are calm and problem-free. 50 x DN 5 x DN 40 x DN 5 x DN 25 x DN 5 x DN 20 x DN 5 x DN 18 x DN 5 x DN 15 x DN 5 x DN Regulating valve1.) 2 x 90° elbow joint 3 dimensional 90° elbow joint or T-piece Expansion2.) Reduction 2 x 90° elbow joint Fluid direction DN = Orifice 1.) If the valve cannot be mounted after the measuring device, the minimal distances have to be respected. 2.) If an expansion cannot be avoided, the minimal distances have to be respected. Please note minimum flow velocity The complete measuring device can be installed in either horizontal or vertical pipes, but following additional conditions should be respected: The pipe always has to be filled with fluid at all times near the device. The pipe design must be such that no air bubbles or cavitation can form within the medium near the device at any time. Correct Incorrect Correct Correct Incorrect Incorrect Correct Incorrect Pressure and temperature ratings must be respected according to the selected fitting material. The suitable pipe size is selected using the diagram in the chapter “Nominal size selection” of the fitting, see chapter “6.2. Selection of the nominal diameter” on page 15

15 | 22Visit product website  6.2. Selection of the nominal diameter The following graph is used to determine the appropriate DN of the pipe and fitting for the application, according to the fluid velocity and the flow rate. On the chart, the intersection of flow velocity and flow rate gives the appropriate diameter. Note: For the fittings listed below, the corresponding nominal size in the bracket must be used: External threads acc. to SMS 1145 Weld ends acc. to SMS 3008, BS4825 1/ASME BPE/DIN 11866 series C or DIN 11850 series 2/DIN 11866 series DIN EN 10357 series A Clamp acc. to SMS 3017, BS 4825 3/ASME BPE or DIN 32676 series For all other fittings, the corresponding nominal diameter without bracket applies. Example 1: nominal flow: 10 m3/h optimal flow rate: 2…3 m/s Result: Select a pipe size of DN Example 2 with external threads according to SMS 1145: nominal flow: 10 m3/h optimal flow rate: 2…3 m/s Result: Select a pipe size of DN 0.1 0.3 0.5 1 3 5 10 0.01 0.02 0.05 0.1 0.2 0.5 100 200 m3/h 0.2 0.5 100 200 500 1000 2000 3000 l/min 0.3 0.5 1 3 5 10 30 m/s fps gpm 0.05 0.1 0.2 0.5 100 200 500 1000 DN65 DN50 (DN65)1.) DN40 (DN50)1.) DN32 (DN40)1.) DN25 (DN32)1.) DN20 (DN25)1.) DN15 (DN15 or DN20)1.) DN08 DN06 S030-HT Flow velocity Flow rate Diameter of example 1 and example 2 Not recommended S030 (standard) DN06 DN08 DN15 (DN15 or DN20) 1.)DN20 (DN25 ) 1.) DN25 (DN32 ) 1.) DN32 (DN40 ) 1.) DN40 (DN50 ) 1.) DN50 (DN65 ) 1.)DN65 Optimal flow rate 1.) See note at the beginning of this chapter . 7. Product operation 7.1. Measuring principle When liquid flows through the pipe, the paddle wheel with 4 inserted magnets is set in rotation producing a frequency signal in the transducer (Hall sensor) of the mounted transmitter. The rotation is detected contactless through the sensor-fitting wall. The frequency mod- ulated induced voltage is proportional to the flow velocity of the fluid.

16 | 22Visit product website  8. Product design and assembly 8.1. Product assembly Note: A complete device to measure the flow rate is made up of an sensor-fitting Type S030 equipped with a paddle wheel sensor and a Bürkert transmitter Type SE30, SE30 Ex, SE32, SE35, SE36 or 8611. The sensor-fitting Type S030 ensures simple installation into pipes from DN 06…DN 65. The transmitter Type SE30, SE30 Ex, SE32, SE35, SE36 or 8611 can be mounted on any sensor-fitting Type S030 and fastened with a bayonet catch. The drawing shows the assembly of a sensor-fitting Type S030 with a process true union connection with nut and solvent/fusion socket and a transmitter Type SE32 (Type S030 + Type SE32 = Type 8032). This also applies to all variants of process connection and compati- ble type of transmitter. See Data sheet Type 8030 Inline flowmeter, Data sheet Type 8032 Inline flowmeter/threshold detector, Data sheet Type 8035 Inline flowmeter or batch controller, Data sheet Type 8036 Inline flowmeter, ELEMENT design or Data sheet Type 8611 eCONTROL - Uni- versal controller for more information. Inline sensor-fitting Type S030 Transmitter Type SE32 9. Product accessories Note: Since March 2012, the Type S030 sensor-fittings in DN 15 and DN 20 have been available in 2 variants with different K factors. Further infor- mation can be found in the user manual in the K factor chapter, see Type S030 /Type S030-HT The 2nd variant is identified by the “v2” marking. This “v2” marking can be found: on the bottom of the DN 15 or DN 20 sensor-fitting in plastic

  • on the side of the DN 15 or DN 20 sensor-fitting in metal Accessories No. Description 1.)

1 Sensor holder

2 O-ring set for metal sensor-fitting

3 O-ring set for plastic sensor-fitting (O-Ring for process

1.) for sensor holder). 1.) Depends on sensor armature variant: flat seal to use for armature with groove (previous variant, no longer available), O-ring seal to use for armature with chamfer (variant “v2”)

17 | 22Visit product website  10. Networking and combination with other Bürkert products Example: Type S030 Transmitter Type SE30  Flow transmitter for Inline sensor-fitting Type SE30 Ex  Flow transmitter for hazardous areas Type SE32  Flow transmitter for Inline sensor-fitting Type SE35  Flow transmitter for Inline sensor-fitting Type SE35  Batch controller for Inline sensor-fitting Type SE36  ELEMENT transmitter for Inline sensor-fit ting Type 8611  eCONTROL - Universal controllers Flowmeter/Threshold detector/ Batch controller/Universal controller Type 8030  Inline flowmeter Type SE30 Ex Inline flowmeter for hazardous areas Type 8032  Inline flowmeter/ threshold detector Type 8035  Inline flowmeter Type 8035  Inline batch controller Type 8036  Inline flowmeter, ELEMENT design Type 8611 eCONTROL - Inline Universal controllers PNP/NPN output or current modulation according to NAMUR 1.) Type 8619  multiCELL - transmitter/controller Type 8025  Flow transmitter Type 8611  eCONTROL - Universal controller panel, wall or rail-mounting variant 1.) Only for SE30Ex: depending on the category, to be used with an intrinsic safety barrier with NAMUR input

18 | 22Visit product website  11. Ordering information 11.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 11.2. Recommendation regarding product selection A complete device to measure the flow rate is made up of a compact sensor-fitting (Type S030) with paddle wheel and a transmitter (Type SE30, SE30 Ex, SE32, SE35, SE36 or 8611). Two different components must be ordered in order to select a complete device. The following information is required: Article no. of the desired flow transmitter (see Data sheet Type 8030 , Data sheet Type 8032 , Data sheet Type 8035 , Data sheet Type 8036 or Data sheet Type 8611 Article no. of the selected S030 sensor-fitting (see chapter “11.4. Ordering chart” on page 19 11.3. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter

19 | 22Visit product website  11.4. Ordering chart Metal sensor-fitting Standard Article no. DN 1.)- DN 06 1.)- DN 08 1.)- DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 Brass - with PVDF paddle wheel - Fluid temperature max. 100 °C, PN FKM seal Internal thread connection G – – – 423980  423981  423982  423983  423984  423985  – NPT – – – 423986  423987  423988  423989  423990  423991  – Rc – – – 423992  423993  423994  423995  423996  423997  – External thread connection G 552557  552527  444023  423998  423999  424000  424001  – – – NPT – – 449182 Rc – – 448668 Stainless steel - with PVDF paddle wheel - Fluid temperature max. 100 °C, PN FKM seal Internal thread connection G – – – 424004  424005  424006  424007  424008  424009  – NPT – – – 424010  424011  424012  424013  424014  424015  – Rc – – – 424016  424017  424018  424019  424020  424021  – External thread connection G 552733  552559  444029  424022  424023  424024  424025  – – – NPT – – 449050 Rc – – 448669 Weld end spigot connection EN ISO 1127/ ISO 4200/ DIN 11866 series B – – 552845 3.) 424028  424029  424030  424031  424032  424033  – Clamp connection DIN 32676 series B – – – 424034 4.) 424035  424036  424037  424038  424039  – Flange connection EN 1092 1/B1/PN 16 – – – 424040  424041  424042  424043  424044  424045  – ANSI B16 - 5 – – – 424046  424047  424048  424049  424050  424051  – JIS 10K – – – 430108  430109  430110  430111  430112  430113  – EPDM seal External thread connection SMS 1145 – – – – – 443306  – 443307  443308  – Weld end spigot connection SMS 3008 – – – – – 443298  – 443299  443300  443374 6.) BS 4825-1/ ASME BPE/ DIN 11866 series C 5.) 443370  443371  443372  443373  443374  DIN 11850 series 2/ DIN 11866 series DIN EN 10357 series A – – 551788  551789  551790  551791  – 551792  551793  – Clamp connection SMS 3017 – – – – – 443302  – 443303  443304  443399  6.) SMS 3017 2.) – – – – – 443387  – 443388  443389  443720  6.) BS 4825-3/ ASME BPE 5.) 443396  – 443397  443398  443399  BS 4825 ASME BPE 2.) – – – – 443400  443717  – 443718  443719  443720  DIN 32676 series A – – 551794 4.) 551795  4.) 551796  551797  – 551798  551799  –

20 | 22Visit product website  Standard Article no. DN 1.)- DN 06 1.)- DN 08 1.)- DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 Stainless steel - with PVDF paddle wheel - Fluid temperature max. 100 °C, PN FKM seal Internal thread connection G – – – 427138  425737  425729  427152  427153  427154  – 1.) External thread 2.) Internal surface finish Ra < 0.8 µm 3.) EPDM seal 4.) Refer to clamp with D dimensions of 34 mm (see chapter “Clamp connection” on page 10 5.) DN 20 (¾") only available in ASME BPE 6.) Refer to ASME BPE Further variants on request Process connection External thread connection: Metric in mm Plastic sensor-fitting Standard Article no. DN 1.)- DN 06 1.)- DN 08 1.)- DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 PVC - with PVDF paddle wheel - Fluid temperature max. 50 °C, PN FKM seal True union connection with nut and solvent socket DIN 8063 – – 444022  423938  423939  423940  423941  423942  423943  – ASTM D 1785/76 – – – 423950  423951  423952  423953  423954  423955  – JIS K – – – 429072  429073  429074  429075  429076  429077  – External thread connection G – 552560  444025 Solvent spigot connection DIN 8063 – – – 423944  423945  423946  423947  423948  423949  – True union connection with nut and without socket – – – – 430734  430735  430736  430737  430738  430739  – EPDM seal True union connection with nut and without socket – – – – 430740  430741  430742  430743  430744  430745  – PP - with PVDF paddle wheel - Fluid temperature max. 80 °C, PN FKM seal True union connection with nut and fusion socket DIN 16962 – – – 423956  423957  423958  423959  423960  423961  – Fusion spigot connection DIN 16962 – – – 423962  423963  423964  423965  423966  423967  – PVDF - with PVDF paddle wheel - Fluid temperature max. 100 °C, PN FKM seal True union connection with nut and fusion socket ISO 10931 – – – 423968  423969  423970  423971  423972  423973  – External thread connection ISO 10931 – – 444028 Fusion spigot connection ISO 10931 – – – 423974  423975  423976  423977  423978  423979  – 1.) External thread

21 | 22Visit product website  Stainless steel sensor-fitting (S030-HT variant) Note: Only mount with transmitter Type SE30 in variant High Temperature (Type SE30-HT). This combination gives the High Temperature flowmeter variant (Type 8030-HT), see Data sheet Type 8030 Standard Article no. DN 1.) -¼" DN 1.) -½" DN 15 DN 20 DN 25 DN 32 DN 40 DN With stainless steel paddle wheel - Fluid temperature max. 125 °C, PN 25 (max. 90 °C, PN 40) FKM seal Internal thread connection G – – 449726  449727  449728  449729  449730  449731 NPT – – 449733  449734  449735  449736  449737  449738 Rc – – 449740  449741  449742  449743  449744  449745 External thread connection G 552735  449725 NPT – 449732 Rc – 449739 Weld end connection EN ISO 1127/ISO 4200/ DIN 11866 series B – – 551757  551758  551759  551760  551761  551762 1.) External thread Further variants on request Material EPDM seal Process connection Clamp or flange 11.5. Ordering chart accessories Note: Since March 2012, the Type S030 sensor-fittings in DN 15 and DN 20 exist in 2 variants, with different K factors. The 2nd variant is identified by the “v2” marking. See chapter “9. Product accessories” on page 16 Description Article no. Sensor armature set Sensor armature made of stainless steel with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 06, DN 08, DN 15 v2 and DN 20 v2 448678 Sensor armature made of stainless steel with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN (except DN 15 v2 and DN 20 v2)...DN 432306 Sensor armature made of stainless steel with paddle wheel (PVDF), seal (EPDM), screws and test certificate for DN (except DN 15 v2 and DN 20 v2)...DN 432305 Sensor armature made of stainless steel with paddle wheel (PVDF), seal (EPDM), screws and test certificate, Ra int. < 0.8 µm for DN 15 (except DN 15 v2 and DN 20 v2)...DN 434149 Sensor armature made of stainless steel with paddle wheel (PP), seal (EPDM), screws and test certificate for DN 06, DN 08, DN 15 v2 and DN 20 v2 554896 Sensor armature made of stainless steel with paddle wheel (PP), seal (EPDM), screws and test certificate for DN (except DN 15 v2 and DN 20 v2)...DN 449425 Sensor armature made of brass with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 06, DN 08, DN 15 v2 and DN 20 v2 448677 Sensor armature made of brass with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 432304 Sensor armature made of brass with paddle wheel (PVDF), seal (EPDM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 432303 Sensor armature made of brass with paddle wheel (PP), seal (EPDM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 449866 Sensor armature made of PVC with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 06, DN 08, DN 15 v2 and DN 20 v2 448674 Sensor armature made of PVC with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 432298

22 | 22Visit product website  Sensor armature made of PVC with paddle wheel (PVDF), seal (EPDM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 432297  Sensor armature made of PVC with paddle wheel (PP), seal (EPDM), screws and test certificate for DN 15 (except DN v2 and DN 20 v2)...DN 443982 Sensor armature made of PP with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 15…DN 65 432300 Sensor armature made of PP with paddle wheel (PVDF), seal (EPDM), screws and test certificate for DN 15…DN 65 432299 Sensor armature made of PP with paddle wheel (PP), seal (FKM), screws and test certificate for DN 15…DN 65 552881 Sensor armature made of PP with paddle wheel (PP), seal (EPDM), screws and test certificate for DN 15…DN 65 443983 Sensor armature made of PVDF with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 06, DN 08, DN 15 v2 and DN 20 v2 448676 Sensor armature made of PVDF with paddle wheel (PVDF), seal (FKM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 432302 Sensor armature made of PVDF with paddle wheel (PVDF), seal (EPDM), screws and test certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 432301 Sensor armature set for High Temperature variant Sensor armature made of stainless steel with paddle wheel (stainless steel), seal (FKM) and screws for DN 15 (except DN v2 and DN v2)...DN 551764 Sensor armature made of stainless steel with paddle wheel (stainless steel), seal (FKM) and screws for DN 06, DN 08, DN v2 and DN 449723 Sensor armature made of stainless steel with paddle wheel (stainless steel), seal (EPDM) and screws for DN 15 (except DN v2 and DN v2)...DN 551763 Sensor armature in stainless steel with paddle wheel (stainless steel), seal (EPDM) and screws for DN 06, DN 08, DN v2 and DN 449724 O-ring set FKM O-ring for metal fitting, DN 06…DN 65 426340 EPDM O-ring for metal fitting, DN 06…DN 65 426341 FKM O-ring for plastic fitting, DN 08 448679 FKM O-ring for plastic fitting, DN 15 431555 FKM O-ring for plastic fitting, DN 20 431556 FKM O-ring for plastic fitting, DN 25 431557 FKM O-ring for plastic fitting, DN 32 431558 FKM O-ring for plastic fitting, DN 40 431559 FKM O-ring for plastic fitting, DN 50 431560 EPDM O-ring for plastic fitting, DN 08 448680 EPDM O-ring for plastic fitting, DN 15 431561 EPDM O-ring for plastic fitting, DN 20 431562 EPDM O-ring for plastic fitting, DN 25 431563 EPDM O-ring for plastic fitting, DN 32 431564 EPDM O-ring for plastic fitting, DN 40 431565 EPDM O-ring for plastic fitting, DN 50 431566 Approvals and conformities 3-point flow calibration certificate 1.) 550676  Inspection certificate 3.1 (according to EN ISO 10204) 803723 Test report 2.2 (according to EN ISO 10204) 803722 Certification of conformity for the surface finish (according to DIN4762, DIN4768, ISO/4287/1) 804175 FDA declaration of conformity 803724 1.) S030 combined with the plugged-in flow transmitter, only for DN ≤ 200