5420 BURKERT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 11
Technical content
Visit product website DATA SHEET Type 1087 Timer Type 2518 Cable Plug DIN EN 175301 803 - F orm A Type 2000 Pneumatically operat- ed 2/2 way angle seat valve CLASSIC Type 2511 Cable Plug Form A Type 2513 Cable plug acc. to DIN EN 175301 803 F orm A 1000011020 | Standard | EU | en | 201906 | 07 4/2 way Solenoid Valve for pneumatics
- Compact design P ush-over solenoid coil Exhaust air can be r egulated T ube, threaded and sub-base connections Ser vo-diaphragm seat discs The Type 5420 is a pilot-controlled 4-way seat valve with servo-diaphragms. A minimum differential pressure of 2.5 bar is needed for switch-over. The valve can be mounted on two channel manifolds with a common pressure supply. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 5420 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 11Visit product website Table of contents 1. Gener al technical data 3 Cir cuit functions Materials 4. Dimensions 5 4.2. Dimension for A TEX/IECEx version 5. P roduct accessories 7 5.2. Special t ool to turn the junction box 6. Or dering information 7 6.2. Bürk ert product filter 6.3. Or dering chart standard version 6.4. Or dering chart ATEX/IECEx version 6.5. Or dering chart accessories Side by side manifolds made of light metal (Aluminium) Cable plug Type 2518, form A acc. to DIN EN 175301 803 Cable plug Type 2513, form A acc. to DIN EN 175301 803 Cable glands for ATEX/IECEx terminal box
3 | 11Visit product website 1. Gener al technical data Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 5 Materials Body Polyamide Seal NBR Coil Polyamide, Epoxy Orifice DN3 Electrical data Operating voltage Standard version: 24 V DC 24/230 V/50…60 Hz ATEX version: 24/110/230 V UC Power consumption V DC version: 2 W V AC version: 11 VA (inrush), 6 VA (hold) Voltage tolerance Performance data Air pressure quality ISO 8573 1:2010, class 7.4.4 Flow r ate (QNn-value air) 200 l/min (Measured at + 20 °C, 6 bar pr essure at valve inlet and 1 bar pressure differ- ence) Duty cycle 100 % continuously r ated Response time Opening: 30 ms (pressure rise 0…90 Closing: 20 ms (pr essure drop 100…10 Medium data Medium Neutr al medium, e.g. lubricated or unlubricated compressed air Medium temperature - °C… Medium pr essure 2.5…10 bar (Overpressure to the atmospheric pressure) Approvals and certificates Protection class IP65 with cable plug Type of protection (ATEX and IECEx) Coil with cable EPS 18 ATEX 1232 X / IECEx EPS 18.0110X II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T95 °C Db Coil with junction bo x EPS 18 ATEX 1232 X / IECEx EPS 18.0110X II 2G Ex eb mb IIC T5 Gb II 2D Ex mb tb IIIC T95 °C Db P roduct connections Port connection G ⅛, tube SL 6/4, sub-base Cable plug Type 2518 Cable plug Type 2518 acc. to DIN EN 175301 803, F orm A (previously DIN 43650, Form A) Detailed information can be found in chapter “Cable plug Type 2518, form A acc. to DIN EN 175301 803” on page Environment and installation Installation As required, preferably with actuator upright Ambient temperature (max.) 55 1.) To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Orifice QNn value Port connection Coil power Pressure range Response times1.) Weight 1 and 3 2 and 4 Opening Closing [mm] [l/min] [W] [bar] [ms] [ms] [kg] 3 200 G ⅛ G ⅛ 3 2.5…10 30 20 ca. 0.4 3 200 SL 6/4 SL 6/4 3 2.5…10 30 20 ca. 0.4 3 200 sub-base1.) G ⅛ 3 2.5…10 30 20 ca. 0.4 3 200 sub-base2.) SL 6/4 3 2.5…10 30 20 ca. 0.4 1.) For full opening a differential pressure of 2.5 bar is required. 2.) Sub-base for mounting on manifolds.
4 | 11Visit product website 2. Cir cuit functions Circuit functions Description 2(B) 4(A) 1(P) 3(R) Type: G, solenoid valve 4/2 way Servo-controlled Normally open 3. Mat erials 3.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? V erify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check
5 | 11Visit product website 4. Dimensions 4.1. Dimension for standar d version Note: Dimensions in mm T ube connection for semi-soft plastic tubes (outer-Ø 6 mm, inner-Ø 4 mm) F or battery mounting, the union nuts on the Ports 1 and 3 are replaced by O-rings (10 2). 101.6 11.2 21.5 18.5 24.5 G1/8 G1/8 G1/8 24.5 18.5 Threaded connection G 1/8
6 | 11Visit product website 4.2. Dimension for A TEX/IECEx version Note: Dimensions in mm 101.6 10.9 Length acc. to order details 6.2 21.5 20.5 68.8 min. R25 18.5 24.5 G1/8 24.5 G1/8 SW27 5.2 32.3 18.5 68.1 41.3 29.7 10.9 101.6 20.5 84.3 R84 Pivoting radius M20x1.5 99.8 174.7 21.5 Version with junction box Version with moulded cable (3 m)
7 | 11Visit product website 5. P roduct accessories 5.1. C able glands for ATEX/IECEx terminal box Note: A cable gland in polyamide version is included in the deliver y. A nickel-plated brass version can be ordered at a surcharge, see “Cable glands for ATEX/IECEx terminal box” on page 10. This special t ool is not supplied with the valve (see “Cable glands for ATEX/IECEx terminal box” on page 10) Description Ex approvals Dimensions Certification Identification Ex cable gland, Brass, nickelplated, 6…13 mm PTB 04 ATEX 1112 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 29…37 mm L 6 mm D 20 mm SW 24 mm E 27 mm Ex cable gland, Polyamide, 7…13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 36…45 mm L 10 mm D 20 mm SW 24 mm E 28 mm 5.2. Special t ool to turn the junction box Note: This special t ool is not supplied with the valve (see “Cable glands for ATEX/IECEx terminal box” on page 10) This special t ool can only be used with ATEX AC10 coils. Set SC02-AC10 Set includes: Special wr ench Ser vice manual 6. Or dering information 6.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now
8 | 11Visit product website 6.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 6.3. Or dering chart standard version Note: Please not e that the cable plug must be ordered separately, see “Cable plug Type 2518, form A acc. to DIN EN 175301 803” on page 9 or separate data sheet for Type 2518 Corr osion-resistant body in polyamide, with coil AC10 (32 mm) , 2 W, seal material NBR A pr essure difference of 2.5 bar is necessary for switch-over. The pr essure range of the following table is 2.5…10 bar. Circuit function Port connection Port connection Orifice QNn value air Article no. per voltage/frequency 024/DC 024/50 60 230/50 [1 and 3] [2 and 4] [mm] [l/min] [V/Hz] [V/Hz] [V/Hz] Type: G, solenoid valve 4/2 way Servo-controlled Normally open 2(B) 4(A) 1(P) 3(R) G ⅛ G ⅛ 3.0 200 134622 134623 134625 Hose fitting 6/4 Hose fitting 6/4 3.0 200 134630 134631 134633 Flange for manifold G ⅛ 3.0 200 134634 134635 134637 Flange for manifold Flange for manifold 6/4 3.0 200 134638 134639 134641 6.4. Or dering chart ATEX/IECEx version Note: Please not e that the cable plug must be ordered separately, see “Cable plug Type 2518, form A acc. to DIN EN 175301 803” on page 9 or separate data sheet for Type 2518 V ersions acc. to Ex m II T5, Polyamide body with manual override; with moulded cable (3 m long) The maximum fluid t emperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K. Junction bo x is available on request. The pr essure range of the following table is 2.5…10 bar. Circuit function Port connec- tion Port connec- tion Orifice QNn value air Electrical connection Application Article no. per voltage/frequency 024/UC 110/UC 230/UC [1 and 3] [2 and 4] [mm] [l/min] [V/Hz] [V/Hz] [V/Hz] Type: G, solenoid valve 4/2 way Servo-controlled Normally open 2(B) 4(A) 1(P) 3(R) G ⅛ G ⅛ 3.0 200 Single unit 350417 On request On request Hose fitting 6/4 Hose fitting 3.0 200 Single unit 350410 On request 350411 Flange for manifold G ⅛ 3.0 200 Block assembly 350414 350415 350416 Flange for manifold Flange for manifold 6/4 3.0 200 Block assembly 350412 On request 350413
9 | 11Visit product website 6.5. Or dering chart accessories Side by side manifolds made of light metal (Aluminium) Total Manifolds Hole spacing A [mm] Total length B [mm] Article no. 2 75 87 005356 3 108 120 005357 4 141 153 005372 5 174 186 005373 6 207 219 005374 8 273 285 006553 Accessories for Manifolds Article no. Silencer 005424 Screw plug for unused ports 1 or 4 005390 Cover, complete, for unused valve positions on manifolds 005432 Nipple with O-rings for connecting junction plate 005049 A±0,20 B ±0,30 G1/4 27 n x 33 M4 - 8 tief 3,5 5,5 9,5 Cable plug Type 2518, form A acc. to DIN EN 175301 - 803 Not For other versions see data sheet Type 2518 Cable plug Dimensions Version Voltage Article no. ca. 51 35.7 3.5 1.5 29.2 Ø 19 29.2 Without circuitry (AC/DC) 0…250 V AC/DC 314802 With LED (AC/DC) 12…24 V AC/DC 314812 With LED and varistor (AC/DC) 12…24 V AC/DC 314820 With rectifier, LED and varistor 12…24 V AC/DC 314816 Cable plug Type 2513, form A acc. to DIN EN 175301 803 Not The cable plug T ype 2513 meets the requirements of ATEX category 3 GD. F or more information on the cable plug, see data sheet Type 2513 Cable plug Circuit diagram Cable length [mm] Article no. BN BU GNYE 12000 260893 5000 260892 3000 260891 300 260890
10 | 11Visit product website Cable glands for ATEX/IECEx terminal box Note: A cable gland in polyamide version is included in the deliver y. A nickel-plated brass version can be ordered at surcharge. F or more information on Ex cable glands, see “6.1. Cable glands for ATEX/IECEx terminal box” on page 12. Description Article no. Ex cable gland, brass, nickelplated, 6…13 mm1.) 773278 Ex cable gland, polyamide, 7…13 mm1.) 773277 Set SC02-AC10: Special wrench2.) incl. service manual 293488 1.) Cable diameter 2.) Not included in the scope of delivery of the valve
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Portugal Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab EmiratesArgentina Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -
74653 Künzelsau
www.burkert.com