120 Watts
- Single, Dual & Triple Outputs
- Convection-cooled
- 3” x 5” Footprint
- High Efficiency to 85%
- Open Frame, U-Channel & Covered Versions
- Low Temperature Option
- Optional Power Fail Detect Signal SDS120 Series Input Input Voltage • 90-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz Input Current • 1.7 A at 115 VAC
1.0 A at 230 VAC
Inrush Current • <30 A at 115 VAC <55 A at 230 VAC Power Factor • 0.97 typical Earth Leakage Current • <0.30 mA at 115 VAC <0.75 mA at 230 VAC Input Protection • 3.15 A on board fuse Output Output Voltage • See table Output Voltage Trim • ±5% output 1 only (3.3 V variant ±10%) Initial Set Accuracy • Single output models: ±1% Multi-output models: ±5% Minimum Load • No minimum load required for single output models. For multi-output models see table. Start Up Delay • 2 s max Start Up Rise Time •2 m s Hold Up Time • >16 ms Line Regulation • 1% maximum, ±0.5% typical Load Regulation • 5% maximum, ±3.0% typical Transient Response • 4% max deviation, recovery to within 1% in 4 ms for a 50% load change Ripple & Noise • 1% pk-pk typical, 20 MHz BW Overvoltage Protection • 112-132% V1 only, recycle input to reset Overload Protection • All outputs: 110-150% with auto recovery (primary power limit) Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery Temperature • 0.04%/°C Coefficient xppower.com General Efficiency • 80% typical, 85% max,
230 VAC 100% load
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • PFC 100 kHz, PWM 67 kHz Power Density • 4.87 W/In Signals • Power Fail Detect = TTL active low, combined AC and DC OK signal (option) MTBF • >100 kHrs per MIL-HDBK-217F Environmental Operating Temperature • 0 °C to +70 °C, derate linearly from 100% load at +50 °C to 50% load at +70 °C, low temperature option ‘-L’ -40 °C Cooling • Convection-cooled Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Vibration • 2 g on 3 axes EMC & Safety Emissions • EN55022, CISPR22 and FCC, part 15 level B conducted Harmonic Currents • EN61000-3-2 Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 2 Perf Criteria A Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, >95% 5000 ms Perf Criteria A, B, B Safety Approvals • EN60950-1, UL60950-1, CSA60950-1 per cUL, CE Mark LVD
4.49 (114.3) 0.10 (2.5) 5.00 (127.0) 4.49 (114.3) 4.00 (101.6) 0.25 (6.4) 3.90 (99.06) M3XP0.5 (Mounting Holes) X 4 DC OUTPUT AC INPUT PFD L N G 0.25 (6.4) 1.54 (39.2) 3.20 (81.4) M3xP0.5 (Mounting Holes) X 3 SDS120 Mechanical Details Models and Ratings Max. Power Output 1 Output 2 Output 3 Model Number(2, 4, 5) Vnom Imin Imax Tol.(1) Vnom Imin Imax Tol.(1) Vnom Imin Imax Tol.(1) 72.0 W 3.3 V 0.00 A 22.00 A 5% SDS120PS03B† 110.0 W 5.0 V 0.00 A 22.00 A 5% SDS120PS05B† 115.0 W 7.0 V 0.00 A 16.42 A 5% SDS120PS07B 120.0 W 9.0 V 0.00 A 13.33 A 4% SDS120PS09B 120.0 W 12.0 V 0.00 A 10.00 A 3% SDS120PS12B† 120.0 W 15.0 V 0.00 A 8.00 A 3% SDS120PS15B† 120.0 W 18.0 V 0.00 A 6.66 A 3% SDS120PS18B 120.0 W 24.0 V 0.00 A 5.00 A 2% SDS120PS24B† 120.0 W 28.0 V 0.00 A 4.28 A 2% SDS120PS28B 120.0 W 36.0 V 0.00 A 3.33 A 2% SDS120PS36B 120.0 W 48.0 V 0.00 A 2.50 A 2% SDS120PS48B† Notes 1. Total regulation includes initial set accuracy, line regulation and load regulation. 2. For optional PCB only version, delete suffix ‘B’ from model number. Example SDS120PS03. 3. For non-standard voltages contact sales office. 4. For optional Power Fail Detect circuit, add suffix ‘P’ to model number 5. For optional -40 ˚C operation, add suffix ‘-L ’ to model number. Notes: 1. Optional Power Fail Detect signal on ‘P’ versions only. Standard models pin 13 is N/C. 2. I/P connector P1 mates with Molex housing 09-50-3051 & Molex 2878 series crimp terminal. 3. O/P P2 mates with Molex housing 09-50-3131 & Molex 2878 series crimp terminal. 4. For optional cover kit order part number SDS120 COVER †, to receive unit with cover fitted add suffix ‘C’ to model number (overall height is 1.73 (44.0)). 5. For mating connector kit order part number SDS120 CON KIT †. 6. For cable harness order part number SDS120S LOOM † for single output models & SDS120M LOOM† for multi-output models. 7. DIN clips are available for alternate mounting order 2 x ‘DIN CLIP’. All dimensions are in inches (mm). Weight: 0.77-0.99 lbs (350-450 g) approx. † Available from Farnell. See pages 204-206. PIN CONNECTIONS Pin Single Dual Triple
1 V1 V2 V2
2 V1 V2 V2
3 V1 V1 V1
4 V1 V1 V1
5 V1 V1 V1
6 V1 V1 V1
7 Return Common Common
8 Return Common Common
9 Return Common Common
10 Return N/C V3
11 Return Common Common
12 Return Common Common
13 PFD(1) PFD(1) PFD(1)
Power Fail Detect (PFD) is +5 V for normal operation. Source current is 5 mA max. PFD is <0.4 V for either AC Fail (<90 VAC) or DC Fail (<95% Vnom). Sink current is 10 mA max. +5 V Pin 13 Internal