300 Watts
- 3.2” x 5” Footprint
- Fits1U Ap plications
- High Efficiency
- Up to 600 W Peak Power
- Single& DualOutputs
- Ou tputVoltagesfrom 5 V to 54 V
- 3 YearWa rranty SDF Series Input InputVoltage • 90-264 VAC InputFrequency • 47-63 Hz InputCurrent • 5.0 A at 90 VAC, 2 A at 230 VAC InrushCurrent • Max 70 A at 230 VAC, 35 A at 115 VAC, cold start 25 °C Power Factor • >0.9 EarthLeakage Current • <1 mA at 264 VAC InputProtection • F5 A / 350 V internal in line fuse Output Output Voltage • See table Output VoltageTrim • ±5% on V1 (V2 of dual output models will track by same % of adjustment) InitialSet Accuracy • ±1% Minimum Load • 1% on single output models, 10% on both outputs of dual output models StartUp Delay • 1.5 s max at 120 VAC StartUp Rise Time • 100 ms typical Hold Up Time • 16 ms min at 80% of full load, 120 VAC LineRegulation • ±0.5% Load Regulation • ±1% 1-100% load for single outputs ±3% V1, ±7% V2 for dual output models (except 0512, ±10% on V2) Over/Undershoot • 5% max TransientResponse • 5% max deviation, recovery to within 1% in 2.5 ms for a 50% load change Ripple& Noise • 1% pk-pk (see note 1) OvervoltageProtection • 105-130% Vnom on output V1, recycle input to reset Overtemperature • Measured internally with auto recovery Protection Overload Protection • 110-140% ShortCircuitProtection • Trip & restart (hiccup mode), auto recovery Remote On/Off • Requires a low signal to inhibit output Fan Supply • 12 VDC, 300 mA, not available on ‘-F’, ‘-E’ or ‘-K’ versions with built-in fan xppo w er.com Ge neral Efficiency • Single output models: typically 87% Dual output models: typically 82% Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
250 VDC Output to Ground
SwitchingFrequency • 40-66 kHz PFC variable, 55 kHz - 75 kHz PWM fixed Power Density • 12.5 W/in 3 Signals • Power Good goes Hi 100-500 ms after output is in regulation and goes Low at least 1 ms before loss of regulation MTBF • 110 kHrs to MIL-HDBK-217F at 25 °C, GB Environm ental OperatingTemperature • 0 °C to +70 °C, derate at 2.5%/ °C from +50 °C to +70 °C StorageTemperature • -20 °C to +85 °C OperatingHumidity • 5-90%, non-condensing StorageHumidity • 5-95%, non-condensing Cooling • ‘-F’, ‘-E’ & ‘-K’ versions have built-in fan, others require 15 CFM to meet forced air ratings OperatingAltitude • 3000 m Vibration • 5-50 Hz, acceleration 7.35 m/s 2 on X, Y and Z axis EMC & Safety Emissions • EN55022 Level B conducted & radiated Harmonic Currents • EN61000-3-2 class A EN61000-3-2 class C for loads ≥20% VoltageFlicker • EN61000-4-2, level 3 Perf Criteria A ESD Immunity • EN61000-3-3 RadiatedImmunity • EN61000-4-3, 3 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Surge • EN61000-4-5, installation class 3, Perf Criteria A Conducted Immunity • EN61000-4-6, 3V Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B SafetyApprovals • UL60950-1, CSA C22.2 No. 950, EN60950-1
Voltage Output Power Output Current Model Number (3,4,5,6) Nominal Peak (2) 5 V 210 W 42.00 A 120.00 A SDF300PS05 (7) 9 V 245 W 27.27 A 66.67 A SDF300PS09 (7) 12 V 300 W 25.00 A 50.00 A SDF300PS12 15 V 300 W 20.00 A 40.00 A SDF300PS15 18 V 300 W 16.67 A 33.30 A SDF300PS18 (7) 24 V 300 W 12.50 A 25.00 A SDF300PS24 28 V 300 W 10.70 A 21.43 A SDF300PS28 (7) 36 V 300 W 8.33 A 16.67 A SDF300PS36 (7) 48 V 300 W 6.25 A 12.50 A SDF300PS48 54 V 300 W 5.56 A 11.10 A SDF300PS54 (7) V1: +5.00 V V2: +12.0 V 240 W 24.00 A 13.33 A 28.80 A
16.00 A SDF300PD0512 (7)
V1: +5.00 V V2: +24.0 V 240 W 24.00 A 6.67 A 28.80 A
8.00 A SDF300PD0524 (7)
V1: +5.00 V V2: +48.0 V 240 W 24.00 A 3.33 A 28.80 A
4.00 A SDF300PD0548 (7)
V1: +12.0 V V2: +24.0 V 240 W 13.33 A 6.67 A 16.00 A
8.00 A SDF300PD1224 (7)
- R ipple & noiseis measured using a 0.1 µF ceram iccapacitorinparallelwith 22 µF electrolyticand 20 MH z bandwidth 2.Peak load can be takenfor 500 µs.A verage power notto exceed m ax power. 3.A dd suffix ‘-F’fortop fancoveroption e.g.SDF3 00P S24-F Add suffix‘-E’forend fan coverw ithscrew term inaloption e.g.SD F300PS24-E Add suffix ‘-K’forend fan coverw ithIEC inletoption e.g.SDF 300P S24-K 4.A dd suffix ‘D’ foroptionaloutputterminalblock on singleoutputmo dels exceptthe5 V,9 V and 12 V outputmod elsw hich are only available withoutput terminalblocks eg.SDF3 00P S24D-F. (7) 5.Add suffix ‘G’foroptionalinputterminalblockseg.SDF 300 PS 24DG-F, except forenclosed withend fan(option ‘-E’) which has input terminalblocks as standard. (7) 6.Add suffix ‘H’foroptionalmolex outputterminalon dualoutputmodels used in convection applications. (7) 7.A vailable forOE M quantities,contactSales. 1. All dimensions are in inches (mm 2. Tolerance: ±0.012 (±0.3) 3. Weight: Enclosed with top fan (option ‘-F’): 1.23 lbs (560 g) Enclosed with end fan (option ‘-E’ &’-K’): 1.32 lbs (600 g) 4. Mounting holes and mating half connectors common to all models. Enclosed withtop fan(Option‘-F ’) Me chanicalDetails 1.60 (40.64) 3.20 (81.28) 0.20 (0.5) 2.23 (56.75) 5.00 (127.00) 0.75 (19.05) A A 4.50 (114.30) 0.25 (6.35) 0.25 (6.35) Voltage Adj. CN3 CN2 Input Connector Voltage Adj. CN3 CN2 Input Connector Terminal block 3 pins 0.25 (6.35) center HD-602-3P A A A A AA 6.50 (165.10) 0.33 (8.26) 0.33 (64.77) 4.50 (114.30) 3.20 (81.28) 1.60 (40.64) 0.25 (6.35) A Mounting hole 6 places M3 x 0.5 ax. screw penetration 0.15 (3.8) Enclosed withend fan(Option‘-E ’)
Output Power Output Current Model Number (3,4,5,6) Forced Cooled ConvectionCooled Forced Cooled ConvectionCooled Peak (2) 5 V 210 W 100 W 42.00 A 20.00 A 120.00 A SDF300PS05 (7) 9 V 245 W 120 W 27.27 A 13.36 A 66.67 A SDF300PS09 (7) 12 V 300 W 150 W 25.00 A 12.50 A 50.00 A SDF300PS12 15 V 300 W 150 W 20.00 A 10.00 A 40.00 A SDF300PS15 18 V 300 W 150 W 16.67 A 8.33 A 33.30 A SDF300PS18 (7) 24 V 300 W 150 W 12.50 A 6.25 A 25.00 A SDF300PS24 28 V 300 W 150 W 10.70 A 5.35 A 21.43 A SDF300PS28 (7) 36 V 300 W 150 W 8.33 A 4.17 A 16.67 A SDF300PS36 (7) 48 V 300 W 150 W 6.25 A 3.12 A 12.50 A SDF300PS48 54 V 300 W 150 W 5.56 A 2.78 A 11.10 A SDF300PS54 (7) V1: +5.00 V V2: +12.0 V 240 W 120 W 24.00 A 13.33 A 12.00 A 6.67 A 28.80 A V1: +5.00 V V2: +24.0 V 240 W 120 W 24.00 A 6.67 A 12.00 A 3.33 A 28.80 A V1: +5.00 V V2: +48.0 V 240 W 120 W 24.00 A 3.33 A 12.00 A 1.67 A 28.80 A V1: +12.0 V V2: +24.0 V 240 W 120 W 13.33 A 6.67 A 6.67 A 3.33 A 16.00 A
- R ipple & noise isme asured using a 0.1 µF ceramic capacitorinparallelwith 22 µF electrolytic and 20 M Hz bandw idth 2.Peak load can be taken for500 µs.A verage power not to exceed m ax power. 3.Ad d suffix‘-C’ forvented coveroptione.g.SDF300PS 24-C 4.A dd suffix‘D’foroptionaloutputterminalblockon singleoutputm odels except the 5 V,9 V and 1 2 V outputmodels which areonlyavailablewith outputterm inalblocks eg.SDF3 00 PS 24D-F. (7) 5.Add suffix ‘G’foroptionalinputterminalblocks eg.SDF 30 0PS24DG-F, except forenclosed withend fan(option ‘-E’)which has inputterminalblocks as standard. (7) 6.Add suffix ‘H’foroptionalmolex outputterminalon dualoutputmodels used in convection applications. (7) 7.Available forO EM quantities,contactSales. U-Channel Mec hanicalD etails 3.20 (81.28) 0.75 (19.05) A AA A A A 0.55 (13.90) 2.70 (68.58) 0.32 (8.26) 2.55 (64.77) L N G 1.75 (44.52) 5.00 (127.00) 1.50 (38.10) 4.50 (114.30) 0.25 (6.35) 0.25 (6.35) CN1 FAN1 CN3 CN2 Voltage Adj. Input Connector 0.75 (19.05) 1.66 (42.10) 3.20 (81.28) CN3 CN2 Input Connector A A 5.00 (127.00) 4.50 (114.30) 0.25 (6.35) 0.25 (6.35) Voltage Adj. A Mounting hole 6 places M3 x 0.5 Max. screw penetration 0.15 (3.8) U-Channel withcover (Option‘-C ’) Notes 1. All dimensions are in inches (mm 2. Tolerance: ±0.012 (±0.3) 3. Weight: U-Channel: 1.08 lbs (490 g) U-Channel with cover (option ‘-C’): 1.12 lbs (510 g) 4. Mounting holes and mating half connectors common to all models. AC -D C
3 pins 0.25 (6.35) center HD-601-3P INPUT CONNECTORS Standard Option ‘G’ L N G NEUTRAL FG LINE CN1 Mating JST part no. VHR-5N or equivalent (5 pin, 3 used) Crimp contacts for JST VHR Series: SVH-21T-P1.1 - 22~18awg SVH-41T-P1.1 - 20~16awg 14-M ay-13 C onnectors Remote On/Off (INH) Fan Fail(FF) Power Good (PG) Thermal Considerations- U Channel CN3 INH PSU CN3 RTN CN3 PG +5 V 1 K CN3 RTN PSU CN3 FF CN3 RTN Fan OK Fan Fail POWER NOT GOOD POWER GOOD AIR FLOW
15 CFM AIR FLOW
15 CFM
No te: 1. Applying <0.3 V or short between pins INH and RTN turns the output OFF. 2. Applying >4.5 V or open circuit between pins INH and RTN turns output ON. 3. The output will enter at hiccup mode. Recommended maximum time is 3 minutes. N ote: 1. Open collector signal: 28 V maximum voltage and 5 mA (maximum sink current) No te: Sink current = 6 mA, Source current = 1 mA Power is good 100-500 ms after output is in regulation. Power not good at least 1 ms before loss of regulation. In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table (right) must not be exceeded. See drawing above for component locations. The temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct airflow). Temperature Measurement Component Max Continuous Temp ºC C26 85 C6 105 C21 105 L6 120 T1 Coil 120 SingleOutput Models Dual Output Models (1)Av ailab leforO EM quan tities,contact Sales. AC-DC OUTPUT CONNECTORS Standard CN2 CN2 Mating JST part no. VHR-6N or equivalent RTN V1 Dual Output models Terminal block M3 screws 0.33 (8.25) 3 pins SIGNALS & FAN CONNECTORS CN3 P .G FF RTN INH FAN1 FF Mating JST Part No XHP-3 with SXH-002T-P0.6 Pins Mating JST Part No XHP-4 Housing SXH-002T-P0.6 Pins RTN Dual Output models Mating JST part no. VHR-8N or equivalent OPTIONAL OUTPUT CONNECTORS (1) CN2 CN2 Option ‘D’(Standard on 5-12 V models) Option ‘H’(only on dual output models in convection-cooled applications) Dinkle PCB terminals P-830 N 2 pins M5 screws