NDS1.138 - Page 1 / 2 Product Datasheet SDD1-100-275-A DINsafe Surge Diverter Use DIN compliant SDD Surge Diverters for distribution boards or for point of entry protection in small industrial and domestic applications. Installing two levels of surge protection, incoming and distributi on boards, greatly increases the protection provided especially if the re is a considerable distance between the two locations. All Mode Protection Protection is provided for all combinations of line s ensuring the maximum level of protection is achieved at all times. Thermal Sensing Sustained overvoltages can cause components to over heat and degrade. Thermal sensing warns of this condition without disconnecting the protection. LED Status Active Display An LED indicates that power is applied and the unit is healthy. An extinguished LED indicates that no power is present on the phase or that an internal overload has occurred. Safe Metal Enclosure Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch re or explode. Wiring Dimensions Standards IEC 61643-11:2011 SPD connected to low-voltage power systems - Type 1 & Type 2 AS/NZS 1768:2007 Low voltage SPD - Type 2 IEEE 62.41.2:2002 Low voltage SPD - Cat B UL 1449 3rd edition Low voltage SPD - Type 2 Generated Fri Sep 17 2021

72 Browns Road, Kingston Tasmania 7050 Australia

NDS1.138 - Page 2 / 2 Product Datasheet Electrical Specications Connection type 1 Shunt Modes of protection 2 L-N, L-PE, N-PE Number of ports 1 Number of phases 3 1 Location Indoor Nominal voltage 4 230VAC Short circuit withstand level 5 50kA Maximum backup fuse 6 63A Recommended SCB SCB1-3-80 Earth leakage current 7 <10μA Electrical (L-N) Specications Maximum continuous voltage AC 8 275VAC Maximum discharge current (8/20 μs) 9 100kA Nominal discharge current (8/20 μs) 0 40kA Lightning impulse current (10/350 μs) n 12.5kA Voltage protection level (3kA 8/20μs) q <800V Voltage protection level (In) q <1700V Response time w <25ns Voltage withstand (5s) e 335V Electrical (N-PE) Specications Maximum continuous voltage 8 255VAC Maximum discharge current (8/20 μs) 9 60kA Lightning impulse current (10/350 μs) n 50kA Nominal discharge current (8/20 μs) 0 50kA Voltage protection level (1kV/μs) q <1000V Voltage protection level (3kA 8/20μs) q <1200V Response time w <100ns Voltage withstand (200ms) e 1200V Follow current interrupt rating r 100A Indication Specications Display t LED power and thermal failure Alarm y SPDT power and thermal failure Alarm isolation u 4kV Mechanical Specications Minimum operating temperature g -40°C Maximum operating temperature h 70°C Minimum operating humidity k 5% Maximum operating humidity j 95% Mounting method a TS35 DIN Rail Environmental rating f IP20 Enclosure material s Aluminium Enclosure nish d Black Powdercoat Terminal capacity - power i 16mm² Terminal screw torque - power o 2Nm Terminal capacity - alarms i 2.5mm² Terminal screw torque - alarms o 0.5Nm Length l 95mm Width ; 36mm Height z 70mm Other Specications Product Code x SDD1-100-275-A Shipping Specications Weight v 295g Customs tariff b 85363000, 85363010 Generated Fri Sep 17 2021