Page 1 of 2 www.aecsensors.com Sales Department Tel: (888) 847-6552 +1 574-293-8013 Ref:SDB 1 60 80 111816FEW Specifications are subject to change without notice. E&OE. SDB1 - 60 - 80 DIN rail 60A & 80A solid-state relays Output (load) Load type SPST-NO (1 N/O) Resistive Load current 60A, 80A Load switching voltage AC Vrms 60 - 660V Maximum peak voltage AC Vpk 900V Minimum load current 0.1A Inrush Current (max.) 10ms 60A: 720A / 80A: 1000A I2t 60A: 2600A2s / 80A: 5000A2s Switch type Zero Cross (Consult factory for Random) On voltage drop V AC 1.6V Leakage current off mA ≤ 10mA Input (control) Control voltage (rated) V DC Control: 4 - 32VDC / AC Control: 90 - 250VAC Control current mA < 20mA Turn-on voltage (min) Vmin DC Control: 3.5VDC / AC Control: 80VAC Turn-on voltage (max) Vmax DC Control: 35VDC / AC Control: 280VAC Turn-off voltage V DC Control: 2VDC / AC Control: 40VAC Insulation Insulation resistance ≤ 500MΩ at 500VDC, 50%RH Dielectric strength V AC ≥ 2500V General Data Operating time (typical) mS Approximately 1/2 cycle of load frequency + ≤1ms Release time (typical) mS Approximately 1/2 cycle of load frequency + ≤1ms Dimensions L x W x H 100 x 110 x 127mm Weight approx. 940g Ambient temperature storage -30 to 100°C (No icing or condensation) operating -30 to 80°C (with derating). (No icing or condensation) Relative Humidity 45 - 85% RH

  • Enhanced load voltage - up to 660VAC with high power dual SCR output.
  • 4 ~ 32VDC or 90 ~ 250VAC control voltage.
  • Single Phase, Zero cross-over switching.
  • LED control input indicator.
  • Integrated heatsink.
  • RoHS Compliant. E325835

Page 2 of 2 www.aecsensors.com Sales Department Tel: (888) 847-6552 +1 574-293-8013 Ref:SDB 1 60 80 111816FEW Specifications are subject to change without notice. E&OE. SDB1 - 60 - 80 DIN rail 60A & 80A solid-state relays Ordering Code S D B 1 Z - 60 U - D Switch Function Z - Zero Crossover R - Random Load Current Rating 60 - 60A 80 - 80A Load Voltage U - 60 to 660VAC Control Voltage Input A - 90 to 250VAC D - 4 to 32VDC Dimensions Dimensions in mm Input Current v. Control Voltage: 4 ~ 32VDC Input Current v. Control Voltage: 90 ~ 250VAC Load Current Derating v. Ambient Temperature Load Output v. Input Control Action (Zero X-over) Fig. 1 Fig. 2 Load or Fuse Control Input DC Control Input AC Control Input