SCX...C Series Low cost compensated pressure sensors 1/4August 2005 / 060 www.sensortechnics.com

FEATURES

  • Low cost
  • Precision temperature compensation
  • Calibrated zero and span
  • Small size
  • Low noise
  • High impedance for low power applications

APPLICATIONS

  • Medical Equipment
  • Computer Peripherals
  • Pneumatic Control
  • H V A C GENERAL DESCRIPTION The SCX...C series sensors will provide a very cost effective solution for pressure applications that require operation over a wide temperature range. These internally calibrated and temperature compensated sensors give an accurate and stable output over a 0°C to 70°C temperature range. This series is intended for use with non-corro- sive, non-ionic working fluids such as air, dry gases, and the like. Devices are available to measure absolute, differential, and gage pressures from 1 psi (SCX01) up to 150 psi (SCX150). The ab- solute (A) devices have an internal vacuum reference and an output voltage proportio- nal to absolute pressure. The differential (D) devices allow application of pressure to either side of the pressure sensing diaphragm and can be used for gage or differential pressure measurements. The SCX devices feature an integrated cir- cuit sensor element and laser trimmed thick film ceramic housed in a compact nylon case. This package provides excellent corrosion resistance and provides isolation to external package stresses. The package has convenient mounting holes and pres- sure ports for ease of use with standard plastic tubing for pressure connection. All SCX devices are calibrated for span to within ±5 % and provide an offset (zero pressure output) of ±1 mV maximum. These parts were designed for low cost applica- tions where the user can typically provide fine adjustment of zero and span in extenal circuitry. For higher accuracies, refer to the standard SCX series datasheet. If the application requires extended temperature range operation, beyond 0 to 70°C, two pins which provide an output voltage pro- portional to temperature are available for use with external circuitry. The output of the bridge is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +20 V is acceptable. Because these devices have very low noise and 100 microsecond response time they are an excellent choice for medical equipment, computer peripherals, and pneumatic control applications. Note: The polarity indicated is for pressure applied to port B (for absolute devices pressure is applied to port A and the output polarity is reversed.) Pin 1) Temperature output (+) Pin 2) V S Pin 3) Output (+) Pin 4)Ground Pin 5) Output (-) Pin 6) Temperature output (-) Bottom view 1 2 3 4 5 6 EQUIVALENT CIRCUIT ELECTRICAL CONNECTION Vs 5+ - Scale: 1 cm ½ inch

SCX...C Series Low cost compensated pressure sensors 2/4 August 2005 / 060 www.sensortechnics.com Part number SCX01DNC SCX05DNC SCX15ANC SCX15DNC SCX30ANC SCX30DNC SCX100ANC SCX100DNC SCX150DNC Operating pressure 0 - 1 psid 0 - 5 psid 0 - 15 psia 0 - 15 psid 0 - 30 psia 0 - 30 psid 0 - 100 psia 0 - 100 psid 0 - 150 psid Maximum ratings (for all devices) Environmental specifications (for all devices) Supply voltage VS +20 VDC Temperature range Common-mode pressure 50 psig Compensated 0 to 70°C Lead temperature (soldering, 4 seconds)250°C Operating -40°C to +85°C Storage -55°C to +125°C Humidity limits (non-condensing) 0 to 99 %RH PRESSURE SENSOR CHARACTERISTICS 1 Standard pressure ranges Proof pressure2 20 psid 20 psid 30 psia 30 psid 60 psia 60 psid 150 psia 150 psid 150 psid Full-scale span1,3 COMMON PERFORMANCE CHARACTERISTICS 1 Characteristic Zero pressure offset Combined linearity and hysteresis4 Temperature effect on span (0 to 70°C)5 Temperature effect on offset (0 to 70°C)5 Repeatability6 Input impedance7 Output impedance8 Common-mode voltage9 Response time10 Long term stability of offset and span11 Min. -1.0 --- --- --- --- --- --- 5.7 --- --- Typ. ±0.2 ±0.4 ±0.20 ±0.2 4.0 4.0 6.0 100 ±0.1 Max. +1.0 ±1.0 ±2.0 ±1.0 ±0.5 --- --- 6.3 --- --- Unit mV %FSO %FSO mV %FSO kΩ kΩ V DC µsec mV Typ. 18 mV 60 mV 90 mV 90 mV 90 mV 90 mV 100 mV 100 mV 90 mV Max. 19 mV 62.5 mV 95 mV 95 mV 95 mV 95 mV 105 mV 105 mV 95 mV Min. 17 mV 57.5 mV 85 mV 85 mV 85 mV 85 mV 95 mV 95 mV 85 mV Reference conditions: Unless otherwise noted: supply voltage, VS = 12 V, TA = 25°C, common-mode line pressure = 0 psig, pressure applied to port B. For absolute devices only, pressure is applied to port A and the output polarity is reversed. Maximum pressure above which causes permanent sensor failure. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is ratiometric to the supply voltage. See Definition of Terms. Hysteresis - the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Maximum error band of the offset voltage and the error band of the span, relative to the 25°C reading. Maximum difference in output at any pressure with the operating pressure range and temperature within 0°C to +50°C after: a) 1,000 temperature cycles, 0°C to +70°C b) 1.5 million pressure cycles, 0 psi to full-scale span Input impedance is the impedance between pins 2 and 4. Output impedance is the impedance between pins 3 and 5. This is the common-mode voltage of the output arms (pins 3 and 5) for V S = 12 VDC . Response time for a 0 psi to full-scale span pressure step change, 10 % to 90 % rise time. Long term stability over a one year period. Specification notes: 10. 11.

SCX...C Series Low cost compensated pressure sensors 3/4August 2005 / 060 www.sensortechnics.com TYPICAL PERFORMANCE CHARACTERISTICS

SCX...C Series Low cost compensated pressure sensors 4/4 August 2005 / 060 www.sensortechnics.com SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Description

ORDERING INFORMATION

To order, use the following part number(s) Mounting Accessories 0 to 1 psi differential/gage 0 to 5 psi differential/gage 0 to 15 psi absolute 0 to 15 psi differential/gage 0 to 30 psi absolute 0 to 30 psi differential/gage 0 to 100 psi absolute 0 to 100 psi differential/gage 0 to 150 psi differential/gage Part Number SCX01DNC SCX05DNC SCX15ANC SCX15DNC SCX30ANC SCX30DNC SCX100ANC SCX100DNC SCX150DNC Part number SCXCLIP SCXCNCT SCXSNP1 PHYSICAL DIMENSIONS mass: 10 g dimensions in inches (mm)