HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 1 of 9 FAN REMOTE CONTROL DECODER USED TOGETHER WITH SC5104 DIP20 SDIP22
DESCRIPTION
SC8207 is a high performance electronic fan controller LSI, Speed control, offtimer, nature wind, sleep mode are all built into a single chip. Light control, buzzer output, key control input, as well as remote control decoding circuitry are all provided to build a full function electronic fan with remote control capability having the highest performance with the least external components. Pin assignment and application circuit are optimized for easy PCB layout and cost saving for electronic fan application. SC8207 adopted SDIP22 or DIP20 package.
FEATURES
- Two groups swing function: level swing , coldwind switch level swing , vertical swing * Independent light controlling: extension “ L” * Three operation modes: ordinary, nature and rhythm sleep. * Three speed modes: strong, middle and low * Memory startup mode * Middle wind startup * Buzzer indicator function operation * Two bits consumer code * Builtin 455kHz oscillator circuit * Continued press key for 6 sec, send out “ BiBi” * Cooperate with SC5104 coder can build a full function electronic * "ON/OFF" key select: "ON/OFF" — — “ K” version "ON/SPEED"— — other version * Timer mode: A4: 0.5, 1, 2, 4 hours accumulated timer N3: 1, 2, 4 hours nonaccumulated
APPLICATIONS
- Fan remote controller * Air cleaner * Humidifier * Heater
ORDERING INFORMATION
Part Package Accum ulated Non accumulated Light control Coldwind switch Vertical swing Note: “ A4” indicated have four time output (0.5, 1, 2, 4 hour) accumulated timer mode. “ N3” indicated have three time output (1, 2, 4 hour) nonaccumulated timer mode. “ L” indicated have light output mode.
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 2 of 9 BLOCK DIAGRAM Oscillator Timing Rectifier Decode Key Sense and LED Scan Output Memory Timer Buzzer, Swing/Light Output LED Scan Speed Control VDD VSS LOW MED STR COM 1 SHO1 SHO2 LTO OFF DI OSCO OSCI BUZ TIMER SPEED MODE SW1 LIGHT COM 2 COM 3 SW2 ABSOLUTE MAXIMUM RATING (Ta mb=25°C) Characteristics Symbol Ratings Unit Supply Voltage VDD 0.3~6 V Input/Output Voltage VIN VSS0.3V ~ VDD+0.3V V Power Consumption PD 500 mW Operating Temperature Topr 10 ~ +70 °C Storage Temperature Tstg 40~+125 °C DC ELECTRICAL CHARACTERISTICS (unless otherwise specified, Ta mb=25°C, VDD=5.0V) Characteristics Symbol Test conditions Min. Typ. Max. Unit Supply Voltage VDD 3.0 5.0 6.0 V Static Consumption Current ISB VDDVSS=5Vˈ OSC stop, no load 500 µ A Input High Level Voltage VIH 0.7VDD VDD V Input Low Level Voltage VIL 0 0.3VDD V OFF, MODE, SPEED, TIMER Scan Output Current IOH VDD=5.0V 10 mA COM1~COM3 Scan Output Sink Current IOL VDD=5.0V, Vo=0.7V 40 mA Driver Output Current IOL VDD=5.0V, Vo=0.7V 10 mA Buzzer Output Current IOH VDD=5.0V, Vo=4.3V 5 mA
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 3 of 9 PIN CONFIGURATION PIN DESCRIPTION DIP20 pin no. SDIP22 pin no. Symbol Description 1 LIGHT Light control key input. 1 2 DI Remote control sensor input. 2 3 OFF OFF control key input, shared with LED scan output. 3 4 TIMER TIMER control key input and LED scan output. 4 5 SPEED SPEED key control input and LED scan output. 5 6 MODE MODE key control input and LED scan output. 6 7 COM1 Consumer code C2 select and LED scan common port. 7 8 COM2 Consumer code C1 select and LED scan common port. 8 9 COM3 LED scan common port. 9 10 SW1 LEVEL SWING key control and consumer code select diode connect port. 10 11 SW2 COLD key control˄SC8207A4KS˅/VERTICAL SWING key control port(N3, A4K) 11 12 SHO2 Cold wind motor /vertical swing drive port 12 13 SHO1 Level swing output port 13 14 STR Strong wind drive output 14 15 MED Middle wind drive output 15 16 LOW Low wind drive output 16 17 VDD Positive power 17 18 BUZ Buzzer drive output 18 19 OSCO 19 20 OSCI 455kHz oscillator input/output port 20 21 VSS Negative power 22 LTO Light drive output
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 4 of 9 FUNCTION DESCRIPTIONS SC8207 is an electronic fan control IC, it use electronic touch switch and timer replace the traditional switch and timer. SC8207 improved nature wind and sleep wind mode except hold the traditional fan functions, and improved two groups of swing control and light control function. SC8206 cooperate with SC5104 encode IC, implement the remote control of the fan. “ OFF” key: It used to shut down the power of motor, fan stop operating. And the control circuit resume static state, and stored the operate mode of power on. When started next time, it is activated into the operation mode stored in the operation memory (Timer and sleep wind mode will not be stored). “ON/SPEED” key: It start fan if pressed when fan is off. It turn on the fan with middle wind for increase start mome nt. After three second, it resume low wind mode, or the operation mode stored in the operating memory. This key set the operate mode when fan is on, if successive pressing of ON/SPEED key, it will operate as low wind, middle wind, strong wind, low wind, middle wind … … .go along with cycle. “ON/OFF” key (extension K) It start fan if pressed when fan is off. It turn on the fan with middle wind for increase start mome nt. After three second, it resume low wind mode, or the operation mode stored in the operating memory. It turn off the power when fan is on, fan stopped, control circuit resume static state, and stored the operate mode into memory. When the fan turn on next time, it start in the operate mode in the memory (timer and sleep mode will not be stored). “SPEED” key (extension K) SPEED key is used to turn on the fan change speed of the fan. When successive pressing of SPEED key, fan will operate as follows: low wind, middle wind, strong wind, low wind… … go along with cycle. “MODE” key: It used to select the operating mode. If pressed successively when fan is on, it will operate as follows: normally wind, nature wind, sleep wind, normally, nature wind … … go along with cycle. a) Ordinary wind: the he wind speed is set by SPEED key and does not change as time passes. b) Nature wind: it is set in program, and operate with “ SPEED” key, can produce strong nature wind, middle nature wind, low nature wind, simulate the really nature wind. c) Sleep wind: In sleep wind mode, the wind speed steps down automatically one level every interval, until it reaches low wind level. Where is the rule of down: 1) If fan set in strong wind mode at first, it operate in strong nature wind for half an hour, then switch into middle nature wind, after half an hour switch into low nature wind, until the preset time end or turn off fan. 2) If fan set in middle wind mode at first, it operates in middle nature wind for half an hour, then switch into low nature wind, until the preset time end or turn off fan. 3) If fan set in low nature wind at first, it operates in low nature wind, until the preset time end or turn off.
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 5 of 9 “ TIMER” key: This key used to set the preset off time . Type m ark with “ A4” m ean have four section time output (0.5, 1, 2, 4hour) accumulated. Type m ark with “ N3” m eans have three section time output (1, 2, 4 hour) nonaccumulated. When fan is in the time mode, LED will indicate the re main time, means the fan will stop after the display time . “LEVEL SWING” key: If pressed when fan is in the operate mode, it can control the fan swing, it is invalid when fan stopped. “VERTICAL SWING” key: N3: If pressed when fan is in the operate mode, it can control the fan vertical swing, it is invalid when fan stopped. A4: If pressed when fan is in the operate mode, it can control the fan vertical swing. If continue pressed, fan up to down swing. When release the key, swing stopped. “ COLD WIND” key: If pressed when fan is in the operate mode, it can control the fan coldwind switch, it is invalid when fan stopped. “ LIGHT” key: It is used to control light, is independent of the operate mode. Buzzer output: a) Turn on send out “ BiBi” b) Turn off send out “ Bi“ c) Other available operate (include key press and remote controller receive) send out “ Bi” CONTROL PANEL
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 6 of 9 TYPICAL APPLICATION CIRCUIT Power circuit Controller unit M M M COMPONENTS LIST Symbol value Symbol value FUSE 1A, 250V C4 0.1µ F, R1 2x180Ω /2W C5 47µ F, 10V R2 200kΩ /0. 5W C6, C7 100pF R3 2x47Ω /0.25W D1, D2 1N4007 R4~R9, R16 10KΩ , 0.25W D3 5.1V, 1 W R10~R15 470Ω , 0.25W XL 455KHz R17~R19 120Ω , 0.25W BUZ ϕ 27 R20, R21 560Ω , 0.25W LED ϕ 3x12 C1 1.2µ F, 400VAC D4, D5 1N4148 C2 470µ F, 16V KEY 6mmX7 C3 470µ F, 10V T1~T6 Z00607MA, MAC97A6
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 7 of 9 SC5104 transmitter controller unit
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 8 of 9 PACKAGE OUTLINE DIP203002.54 UNIT: mm 6.60±0.25 7.62TYP 0.25±0.10 4.36MAX3.00MIN SDIP223002.54 UNIT: mm
HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.0 2004.08.03 Http: www.silan.com.cn Page 9 of 9 HANDLING MOS DEVICES: Electrostatic charges can exist in many things. All of our MOS devices are internally protected against electrostatic discharge but they can be damaged if the following precautions are not taken:
- Persons at a work bench should be earthed via a wrist strap.
- Equipment cases should be earthed.
- All tools used during assembly, including soldering tools and solder baths, must be earthed.
- MOS devices should be packed for dispatch in antistatic/conductive containers.