SC2-N0-GN PF | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
2 mm slot width Technical Data General specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5 ... 7 mm , typ. 6 mm Output type 2-wire Nominal ratings Nominal voltage U o 8.2 V (Ri approx. 1 kΩ) Operating voltage U B 5 ... 25 V Switching frequency f 0 ... 5000 Hz Design data Current consumption Measuring plate not detected ≥ 3 mA Measuring plate detected ≤ 1 mA Switching state indicator LED, yellow Functional safety related parameters MTTFd 5790 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Mechanical specifications Connection type cable PVC , 500 mm Core cross-section 0.06 mm 2 Housing material PBT Degree of protection IP67 General information Use in the hazardous area see instruction manuals Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates UL approval cULus Listed, General Purpose Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0453 CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated ≤36 V Dimensions Electrical Connection LED 4,2 ø1,5 121 BN L-BU
Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive slot sensor SC2-N0-GN Release date: 2019-08-27 16:38 Date of issue: 2019-08-27 095288_eng.xml Data for application in connection with hazardous areas Equipment protection level Ga , Gb , Gc (ic) , Da , Mb Equipment protection level Ga Type of protection intrinsic safety CE marking 0102 Certificates Appropriate type SC2-N0... ATEX certificate PTB 99 ATEX 2219 X ATEX marking ¬ II 1G Ex ia IIC T6...T1 Ga Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 IECEx certificate IECEx PTB 11.0091X IECEx marking Ex ia IIC T6...T1 Ga Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 150 nF A cable length of 10 m is considered. Effective internal inductance L i ≤ 150 µH A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. for ATEX at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , at U i = 16 V , Ii = 25 mA , Pi = 64 mW , at U i = 16 V , Ii = 52 mA , Pi = 169 mW , T5 : 35 °C (95 °F) at U i = 16 V , Ii = 76 mA , Pi = 242 mW , for IECEx at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 16 V , Ii = 25 mA , Pi = 64 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 16 V , Ii = 52 mA , Pi = 169 mW , at U i = 16 V , Ii = 76 mA , Pi = 242 mW ,
Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive slot sensor SC2-N0-GN Release date: 2019-08-27 16:38 Date of issue: 2019-08-27 095288_eng.xml Equipment protection level Gb Type of protection intrinsic safety CE marking 0102 Certificates Appropriate type SC2-N0... ATEX certificate PTB 99 ATEX 2219 X ATEX marking ¬ II 1G Ex ia IIC T6…T1 Ga Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 IECEx certificate IECEx PTB 11.0091X IECEx marking Ex ia IIC T6...T1 Ga Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 150 nF A cable length of 10 m is considered. Effective internal inductance L i ≤ 150 µH A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at U i = 16 V , Ii = 25 mA , Pi = 34 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 16 V , Ii = 25 mA , Pi = 64 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 16 V , Ii = 52 mA , Pi = 169 mW , at U i = 16 V , Ii = 76 mA , Pi = 242 mW , Equipment protection level Gc (ic) Type of protection intrinsic safety CE marking Certificates ATEX certificate PF13CERT2895 X ATEX marking ¬ II 3G Ex ic IIC T6...T1 Gc Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 Effective internal capacitance C i ≤ 150 nF A cable length of 10 m is considered. Effective internal inductance L i ≤ 150 µH A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 20 V , Ii = 25 mA , Pi = 64 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 20 V , Ii = 52 mA , Pi = 169 mW , at U i = 20 V , Ii = 76 mA , Pi = 242 mW ,
Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive slot sensor SC2-N0-GN Release date: 2019-08-27 16:38 Date of issue: 2019-08-27 095288_eng.xml Equipment protection level Da Type of protection intrinsic safety CE marking 0102 Certificates Appropriate type SC2-N0... ATEX certificate PTB 99 ATEX 2219 X ATEX marking ¬ II 1D Ex ia IIIC T135°C Da Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 IECEx certificate IECEx PTB 11.0091X IECEx marking Ex ia IIIC T135°C Da Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 150 nF A cable length of 10 m is considered. Effective internal inductance L i ≤ 150 µH A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at U i = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 75 °C (167 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 54 °C (129.2 °F) Equipment protection level Mb Type of protection intrinsic safety Certificates Appropriate type SC2-N0... IECEx certificate IECEx PTB 11.0091X IECEx marking Ex ia I Mb Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 150 nF A cable length of 10 m is considered. Effective internal inductance L i ≤ 150 µH A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 75 °C (167 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 54 °C (129.2 °F)