Digital Output with Shutdown Input LB6116E < 2-channel < Outputs Ex ia < Mounting in Zone 2, Class I/Div.2 or in the safe area < Line fault detection switched on and off < Positive or negative logic selectable < Simulation mode for service operations (forcing) < Permanently self-monitoring < Output with watchdog < Output with bus-independent safety shutdown < Module can be exchanged under voltage (hot swap) Function The digital output features 2 independent channels. The device can be used to drive solenoids, sounders, or LEDs. Open and short circuit line faults are detected in on and off state. The outputs are galvanically isolated from the bus and the power supply. The output can be switched off via a contact. This can be used for bus-independent safety applications. Connection Zone 2 Div. 2 COM Zone 0, 20 Div. 1 single modeparallel mode Technical Data Slots Occupied slots 1 Supply Connection backplane bus Rated voltage Ur Use only in connection with the power supplies LB9*** Power dissipation 1.95 W Power consumption 2.9 W Internal bus Connection backplane bus Interface manufacturer-specific bus to standard com unit Release date: 2021-12--
01 Date of
Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 263862_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Field device Solenoid Valve Field device [2] audible alarm Field device [3] visual alarm Connection channel I: 1+, 4/5/6/8-; channel II: 7+, 4/5/6/8- Current limit Imax 40 mA both channels parallel 80 mA Internal resistor Ri 258 Ω , both channels parallel 129 Ω Open loop voltage 23 V , both channels parallel 23 V Line fault detection can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms) Short-circuit < 50 Ω Open-circuit > 10 kΩ Response time 10 ms (depending on bus cycle time) Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication Indicators/settings LED indication Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1, 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Mode LED (M) white: Parallel operation of outputs Coding optional mechanical coding via front socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Conformity Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 when mounted on backplane Connection removable front connector with screw flange (accessory) Mass approx. 150 g Dimensions 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) Data for application in connection with hazardous areas EU-type examination certificate EXA 16 ATEX 0025X Marking 1 II 3(1) G Ex nA [ia Ga] IIC T4 Gc
1 II (1) D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] I Digital Output with Shutdown Input LB6116E Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 263862_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Voltage Uo 24.2 V Current Io 108 mA Power Po 654 mW Internal capacitance Ci 12 nF Internal inductance Li 0 mH Output (both channels parallel) Voltage Uo 24.2 V Current Io 216 mA Power Po 1307 mW Internal capacitance Ci 24 nF Internal inductance Li 0 mH Galvanic isolation Output/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010 International approvals ATEX approval EXA 16 ATEX 0025X UL approval E106378 Control drawing 116-0426 (cULus) IECEx approval IECEx EXA 16.0010X Approved for Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I General information System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Digital Output with Shutdown Input LB6116E Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 263862_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
I P M Front view Status LED red/yellow output 1 Mode LED white Power LED green Diagnostic LED red/white Socket for removable plug blue (accessory) Status LED red/yellow output 2 Digital Output with Shutdown Input LB6116E Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 263862_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 263862_eng.pdf LB6116E Germany: +49 621 776 2222Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091 Digital Output with Shutdown Input Characteristic Curve Load calculation Output characteristics Us Imax Rload Ie Ue Rload = Field loop resistance Us Ie U (V) I (mA) Ri Imax Ue = Us - Ri x Ie Ie = Us/(Ri + Rload)