SB4-OR-4XP-B-B-B-B PF | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 7
Technical content
< Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4 < Expansion slots for SB4 modules for optional enhanced functionality < Self-monitoring (type 4 according to IEC/EN 61496-1) < Operating mode can be selected by means of DIP switches < 7-segment diagnostic display < Safety outputs OSSD, external status displays OSSD SB4 series safety control unit with optional module slots for functional enhancement Safety tested Production monitored Functional Safety Dimensions X (see table) Model number Number of Housing width X optional slots [mm] SB4-OR-4CP-B 1 67.8 SB4-OR-4CP-B-B 2 90.4 SB4-OR-4CP-B-B-B 3 113 SB4-OR-4CP-B-B-B-B 4 135.6 SB4-OR-4CP-B-B-B-B-B 5 180.8 107.5 112.7 13 14 15 16 9 10 11 12 13 14 15 16 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 13 14 15 16 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 13 14 15 16 9 10 11 12 Technical Data General specifications Operating mode Start/restart disable, relay monitor, Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Performance level (PL) PL e Category Cat. 4 Mission Time (TM) 20 a PFHd see instruction manuals B10d see instruction manuals Type 4 Release date: 2023-02--
15 Date of
Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
Indicators/operating means Diagnostics indicator 7-segment display Function indicator LED red: OSSD OFF LED green: OSSD ON Yellow LED: start readiness channel 1 - 4 LED yellow: switching state (receiver) Stability alarm indicator LED yellow flashing: Indicator lamp channel 1 ... 4 Electrical specifications Operating voltage UB 24 V DC, ± 20 % No-load supply current I0 max. 500 mA Protection class no identification ; see instruction manuals Power dissipation If additional modules are used, max. 50 W Input Activation current approx. 7 mA Test input Reset-input for system test Output Safety output 2 relay outputs, force-guided NO-contact Signal output Output for displaying the switching state of the OSSDs Switching voltage 10 V ... 250 V AC/DC Switching current min. 10 mA , max. 6 A AC/DC Switching power DC: max. 24 VA AC: max. 230 VA Response time 30 ms Conformity Functional safety ISO 13849-1 ; EN 61508 part1-4 Product standard EN 61496-1 Approvals and certificates CE conformity CE UKCA conformity UKCA UL approval cULus TÜV approval TÜV Ambient conditions Relative humidity max. 95 %, not condensing Shock resistance see instruction manuals Vibration resistance see instruction manuals Mechanical specifications Degree of protection IP20 Connection screw terminals , lead cross section 0.2 ... 2 mm2 Material Housing Polyamide (PA) Mass 470 g Safety control unit SB4-OR-4XP-B-B-B-B Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
1 Reset input; NC contact
2 Restart input (RI); NC contact
3 24 V DC connection for reset, restart and RM
4 Relay monitor (RM)
5 - 6 OSSD1; floating relay contact; NO contact 7 - 8 OSSD2; floating relay contact; NO contact
9 Signal output OSSD OFF
10 Signal output OSSD ON
11 Signal output Restart
12 Reserved (n.c.) 13 +24 V DC supply voltage 14 0 V DC supply voltage
15 Functional ground
16 Reserved (n.c.) Terminal position 1 Position 1 Position 2 T erminal Function Channel Connection 2-channel connection Connection Photoelectric sensor/light grid Assignment Safety device P-switching Switching mat 1 Receiver 2 input Input Receiver output 2 OSSD output 1. 2 Switching mat 1.4
2 Sensor 2 24 V DC +U 24 V receiver 2 24 V supply 1
3 Sensor 2 ground GND 0 V receiver 2, transmitter 2 0 V su pply 1
4 T ransmitter 2 output Output T ransmitter input 2 Switchin g mat 1.3 5 Receiver 1 input Input Receiver output 1 OSSD output 1. 1 Switching mat 1.2
6 Sensor 1 24 V DC +U 24 V receiver 1
7 Sensor 1 ground GND 0 V receiver 1, transmitter 1
8 T ransmitter 1 output Output T ransmitter input 1 Switchin g mat 1.1 9 T ransmitter 3 output Output T ransmitter input 3 Switchin g mat 2.4
10 Sensor 3 ground GND 0 V receiver 3, transmitter 3 0 V supply voltage 2
11 Sensor 3 24 V DC +U 24 V receiver 3 24 V supply voltage 2
12 Receiver 3 Input Input Receiver output 3 OSSD output 2.2 Switching mat 2.3 13 T ransmitter 4 output Output T ransmitter input 2 Switching mat 2.2
14 Sensor 4 ground GND 0 V receiver 4, transmitter 4
15 Sensor 4 24 V DC +U 24 V receiver 4
16 Receiver 4 input Input Receiver output 4 OSSD output 2.1 Switching mat 2.1 Terminal position 2 The information applies only to the basic device. If additional SB4 modules are used, the operating instructions that accompany the device must be observed during planning, installation and operation. OSSD RI 13 14 15 16 9 10 11 12 13 14 15 16 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Matching System Components SLP8-2 Safety light grid SLP8-2-A-L Safety light grid, active column SLP8-2-L Safety light grid SLP8-2-M Deviation mirror SLP10-2 Safety light grid SLP10-2-L Safety light grid SLP10-3 Safety light grid SLP10-3-L Safety light grid Safety control unit SB4-OR-4XP-B-B-B-B Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
Matching System Components SLP10-4 Safety light grid SLP10-4-L Safety light grid SLCT14 Safety light curtain SLCT14-*-3702 Safety light curtain SLCT30 Safety light curtain SLCT30-/35 Safety light curtain SLCT30-*-3702 Safety light curtain SLCT60 Safety light curtain SLCT60-/35 Safety light curtain SLCT90 Safety light curtain SLCT90-/35 Safety light curtain SLCS14 Safety light curtain SLCS14-*-3702 Safety light curtain SLCS14-*-3702 Safety light curtain SLCS30 Safety light curtain SLCS30/35 Safety light curtain SLCS30-*-3702 Safety light curtain SLCS30-*-3702 Safety light curtain SLCS60 Safety light curtain SLCS60/35 Safety light curtain Safety control unit SB4-OR-4XP-B-B-B-B Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
Matching System Components SLCS90 Safety light curtain SLCS90/35 Safety light curtain SLCT-M-01 Inclined mirror for stable 90° deflection with cover plate SLCT-M-01-1200 Inclined mirror for stable 90° deflection with cover plate SLCT-M-01-1500 Inclined mirror for stable 90° deflection with cover plate SLCT-M-01-2100 Inclined mirror for stable 90° deflection with cover plate SLC-XXX-M Safety light grid mirror Safety control unit SB4-OR-4XP-B-B-B-B Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf SB4-OR-4XP-B-B-B-B Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Safety control unit The operating instructions that accompany the unit must be observed during planning, installation and operation. The SB4 evaluation system is a type 4 (EN 61496-1 or IEC 61496-1) and category 4 (EN 954-1) AOPD. This system has also been designed and tested in accordance with IEC 61508. The system meets the requirements of SIL3. At most 4 safety thru-beam sensors can be connected to the control interface in the default setting. The SB4 module at position 2 enables SLA-series "3-wire" thru-beam sensors (such as SLA5) and SLP light grids to be connected. P-switching safety devices with integrated cross-circuit monitoring can also be connected, such as SLC series safety light curtains. Switching mats designed according to the 4-wire principle and single or dual-channel contact-equipped safety sensors can also be connected. The cables must be selected for and routed to the photoelectric sensors and light grids in such a way as to ensure short circuits cannot occur between the receiver and the emitter wire. Light curtains with semiconductor switching outputs and dual-channel contact-equipped safety sensors are monitored for simultaneity The monitoring time is 2 seconds. The devices are connected at channels 3 and 4 and/or 1 and 2. Please note that these sensors must feature integrated cross- circuit monitoring, as the module in these sensors is not designed to include this feature. Contact-equipped safety sensors that are connected to the SafeBox must operate normally closed outputs. An open contact signifies that the status is "safe". Switching mats designed in accordance with the 4-wire principle can be connected to channels 1 and 2 and/or 3 and 4. The control interface has empty slots. They are used for individual function extensions with SB4 modules. The following SB4 modules can be used:
- SB4 modules 4C:SB4 modules 4C in various versions. SB4 module for connecting four 2-wire sensors
- SB4 modules 4X:SB4 modules 4X in various versions. SB4 module for connecting 3-wire sensors and safety devices with semiconductor switching outputs
- SB4 modules 6C:SB4 modules 6C in various versions. SB4 module for connecting six 2-wire sensors
- SB4 modules 2E:SB4 modules 2E in various versions. Additional 2 OSSDs, relay monitoring, restart connection and 2 connections for contact-equipped safety signals(e.g. emergency off switch), timer functions
- SB4 modules 4M:SB4 modules 4M in various versions. Muting module for connecting up to 4 muting sensors The startup/restart interlock is activated by default. All groups feature DIP switches to select the functions. Two switches must always be actuated in order to select a function. Switches on the first group: Switches on the second group: Six DIP switches for selecting the sensor type and position are available on the module. There are six ways in which to combine the sensors. The required combination must be set in binary form. Two switches must always be actuated in order to select a function, e.g. DIP switches 1–3 have the same switch position as DIP switches 4–6. Function Operating modes Switch Position Operating mode 1 and 3 OFF without startup/restart interlock (restart, RI) ON with startup/restart interlock (restart, RI) 2 and 4 OFF without relay monitor (RM) ON with relay monitor (RM) DIP switches Operating mode 3 and 2 and 1 and 0 0 0 SLA/SLP/bridge on channel 1 + 2 and channel 3 + 4 0 0 1 SLA/SLP/bridge on channel 1 + 2 and SLC channel 3 + 4 0 1 0 SLC channel 1 + 2 and channel 3 + 4 0 1 1 SLA/SLP/bridge on channel 1 + 2 and pressure-sensitive mat channel 3 + 4 1 0 0 Pressure-sensitive mat channel 1 + 2 and channel 3 + 4 1 0 1 SLC channel 1 + 2 and channel 3 + 4
Release date: 2023-02-15 Date of issue: 2023-02-15 Filename: 240959_eng.pdf SB4-OR-4XP-B-B-B-B Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Safety control unit The OSSD-R/supply module in position 1 features a red/green LED to signal the OSSD off/on statuses, a yellow LED to indicate the "Ready for startup" status and a 7-segment display for system diagnostics. The 7-segment display signals the system status and error codes. Indicators Displ ay 7-segment display
1 DIP switch setting not identical
2 Incorrect configuration
3 Time-out of one or more muting sensors
4 Transmitter fault
6 Muting lamp fault
7 Simultaneity monitoring fault
8 Receiver fault
9S e n s o r c h a n n e l f a u l t CS e n s o r c h a n n e l f a u l t E System fault F Relay monitor fault H Selection chain fault L Configuration fault U Under/overvoltage detected