SA8702 02.02.93 BLOCK MODE TIME SLOT ALLOCATION CIRCUIT Figure 1.

DESCRIPTION

The SA8702 (BMTSAC) is a Block Mode Time Slot Allocation Circuit. The device is used to generate 8 consecutive timeslots in one of 4 blocks in a 32 time-slot PCM system. Each timeslot pulse is 8 BLCK cycles long. BCLK is the 2,048 station clock provided by the system. An active MRST will disable all outputs until a valid XSYNC input is recognised. The output TSX is delayed by half a cycle and indicates that one of 8 timeslots is currently active. There are 4 possible modes of operation, selectable by means of the BL0 and BL1 pins (See Table 1).

APPLICATIONS

I PCM Transmission Systems I Subscriber Multiplex Equipment I PBX Systems PIN CONNECTIONS All inputs and outputs are C-MOS compatible. All outputs are push-pull with the exception of TSX which is open drain. The inputs MRST and BCLK are Schmitt Trigger. Inputs BL0 and BL1 have pull-ups. (See figure 1).

Table 1. Input pulse XSYNC occurs periodically in every frame and is used to generate the first of the eight timeslots and also defines the beginning of Block 0. If XSYNC fails high then the outputs will be generated as they were before the failure occured. Should XSYNC fail low then the outputs will be deactivated after completion of the frame. Maximum Ratings All voltages measured with respect to V SS . Parameter Symbol Value Units Supply voltage V DD +7,5 V Positive voltage on any pin V HM VDD +0,3 V Negative voltage on any pin V LM VSS -0,3 V Maximum current through any pin I HM ±10 mA Storage temperature T ST -55 to +150 °C Operating temperature T O -10 to +70 °C Stresses beyond these values may cause permanent damage to the device. Exposure to maximum rated conditions for extended periods may affect device reliability. Operating Modes BL1 BL0 Mode of Operation 0 0 Outputs active in timeslots 0 to 7 0 1 Outputs active in timeslots 8 to 15 1 0 Outputs active in timeslots 16 to 23 1 1 Outputs active in timeslots 24 to 31

AC Parameters Symbol Min. Nom. Max. Unit Conditions XSYNC setup before T s 60 - - ns 4,75 ≤ VDD BCLK goes low ≤ 5,25 Output propagation T pd - - 150 ns 4,75 ≤ Vdd delay from active clock ≤ 5,25 edge XSYNC hold time from T h 50 - - ns 4,75 ≤ VDD BCLK ≤ 5,25 Operating Conditions: All voltages measured with respect to VSS . Inputs must never be left open. DC Parameters Symbol Min. Nom. Max. Unit Conditions Supply Voltage V DD 4,75 5,00 5,25 V - * Input Low Voltage V IL - - 1,0 V V DD = 5V * Input High Voltage VIH 4,0 - - V V DD = 5V Output Low Voltage V OL - - 0,5 V V DD = 5V Iol = 0,5mA Output High Voltage VOH 4,5 - - V V DD = 5V Ioh = 0,5mA Operating Frequency - 2,048 2,273 MHz 4,75 ≤ VDD ≤ 5,25 Operating Temp. range -10 25 70 °C - * All inputs are C-MOS level compatible. Pins 6 and 7 have internal pull-up devices. ** All outputs are push-pull except pin 1 which is open drain.

Pin No. I/O Name Description

1 O TSX An open drain N-channel high impedance, but pulls

low during any active timeslot.

2 I MRST A Schmitt trigger input that asynchronously disables

all outputs.

3 O FSO A timeslot output which is normally low, and goes

active-high for 8 cycles of BCLK when a valid XSYNC is made. 4 O FS1 Similar to pin 3. 5 O FS2 Similar to pin 3.

6 I BL0 The input for the LSB of the 2 bit word which defines

the active block.

7 I BL1 The input for the MSB of the 2 bit word which defines

the active block. 8 I VSS The OV ground connection to the device. 9 I BCLK The 2,048MHz station clock input.

10 I XSYNC The input pulse XSYNC used to generate the first of

the eight timeslots and also defines the beginning of block 0. 11 O FS7 Similar to pin 3. 12 O FS6 Similar to pin 3. 13 O FS5 Similar to pin 3. 14 O FS4 Similar to pin 3. 15 O FS3 Similar to pin 3. 16 I VDD The positive supply to the device.

Any sales or technical questions may be posted to our e-mail adress below: energy@sames.co.za For the latest updates on datasheets, please visit our web site: http://www.sames.co.za South African Micro-Electronic Systems (Pty) Ltd P O Box 15888, 33 Eland Street, Lynn East, Koedoespoort Industrial Area,

0039 Pretoria,

Republic of South Africa, Republic of South Africa Tel: 012 333-6021 Tel: Int +27 12 333-6021 Fax: 012 333-8071 Fax: Int +27 12 333-8071 Disclaimer: The information contained in this document is confidential and proprietary to South African Micro- Electronic Systems (Pty) Ltd ("SAMES") and may not be copied or disclosed to a third party, in whole or in part, without the express written consent of SAMES. The information contained herein is current as of the date of publication; however, delivery of this document shall not under any circumstances create any implication that the information contained herein is correct as of any time subsequent to such date. SAMES does not undertake to inform any recipient of this document of any changes in the information contained herein, and SAMES expressly reserves the right to make changes in such information, without notification,even if such changes would render information contained herein inaccurate or incomplete. SAMES makes no representation or warranty that any circuit designed by reference to the information contained herein, will function without errors and as intended by the designer.