24V Mini Family Rev 4.9 vicorpower.com Page 1 of 15 01/2016 800 927.9474 S NRTLCU SC US Actual size: 2.28 x 2.2 x 0.5in 57,9 x 55,9 x 12,7mm Features & Benefits
- DC input range: 18 – 36V
- Isolated output
- Operation to 16V at 75% power after startup
- Input surge withstand: 50V for 100ms
- DC output: 3.3 – 48V
- Programmable output: 10 to 110%
- Regulation: ±0.5% no load to full load
- Efficiency: Up to 89%
- Maximum operating temp: 100°C, full load
- Power density: up to 80 W per cubic inch
- Height above board: 0.43in. (10,9mm)
- Parallelable, with N+M fault tolerance
- Low noise ZCS/ZVS architecture
- RoHS Compliant (with F or G pin option) Product Overview These DC-DC converter modules use advanced power processing, control and packaging tech- nologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Parameter Rating Unit Notes +In to –In voltage -0.5 to +53 VDC PC to –In voltage -0.5 to +7.0 VDC PR to –In voltage -0.5 to +7.0 VDC SC to -Out voltage -0.5 to +1.5 VDC -Sense to -Out voltage 1.0 VDC Isolation voltage in to out 3000 VRMS Test voltage in to base 1500 VRMS Test voltage out to base 500 VRMS Test voltage Operating Temperature -55 to +100 °C M-Grade Storage Temperature -65 to +125 °C M-Grade Pin soldering temperature 500 (260) °F (°C) <5 sec; wave solder 750 (390) °F (°C) <7 sec; hand solder Mounting torque 5 (0.57) in-lbs (N-m) 6 each Output Power VOUT P OUT 3.3V 100W, 150W 5V 150W, 200W 6.5V 200W 8V 200W 12V 150W, 200W, 250W 15V 150W, 200W 24V 150W, 200W, 250W 28V 150W, 200W, 250W
36 V 150W, 200W
48 V 150W, 200W, 250W
e.g. V24B12T200BL2 Absolute Maximum Ratings 24B B
Applications
Industrial and process control, distributed power, medical, ATE, communications, defense, and aerospace. For details on proper operation please refer to the: Design Guide & Applications Manual for Maxi, Mini, Micro Family. Output Voltage 3V3 = 3.3V 5 = 5V 6.5 = 6.5V 8 = 8V 12 = 12V 15 = 15V 24 = 24V 28 = 28V 36 = 36V 48 = 48V Product Grade Temperatures (°C) Grade Operating Storage E = -10 to +100 -20 to +125 C = -20 to +100 -40 to +125 T = -40 to +100 -40 to +125 H = -40 to +100 -55 to +125 M = -55 to +100 -65 to +125 Pin Style Finish Blank: Short Tin/Lead L: Long Tin/Lead S: Short ModuMate Gold N: Long ModuMate Gold F: Short RoHS Gold G: Long RoHS Gold K: Extra Long RoHS Gold Baseplate Blank: Slotted 2: Threaded 3: Through-hole Product Type V = Standard S = Enhanced efficiency (avail. ≤12 Vout only)
24V Mini Family Rev 4.9 vicorpower.com Page 2 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Operating input voltage 18 24 36 VDC Input surge withstand 50 VDC <100ms Undervoltage turn-on 17.5 17.9 VDC Undervoltage turn-off 14.8 15.3 VDC Overvoltage turn-off/on 36.3 37.8 39.6 VDC Disabled input current 4.0 VDC PC pin low Parameter Min Typ Max Unit Notes Output voltage setpoint ±1% VOUT nom. Nominal input; full load; 25°C Line regulation ±0.02 ±0.20 % Low line to high line; full load Temperature regulation ±0.002 ±0.005 %/°C Over operating temperature range Power sharing accuracy ±2 ±5 % 10 to 100% of full load Of nominal output voltage. For trimming below 90% Programming range 10 110 % of nominal, a minimum load of 10% of maximum rated power may be required. +Out to –Out, +Sense to –Out — Absolute Maximum Ratings 3.3V -0.5 to 4.7 VDC Externally applied 5V -0.5 to 7.0 VDC Externally applied 6.5V -0.5 to 9.1 VDC Externally applied 8V -0.5 to 10.9 VDC Externally applied 12V -0.5 to 16.1 VDC Externally applied 15V -0.5 to 20.0 VDC Externally applied 24V -0.5 to 31.7 VDC Externally applied 28V -0.5 to 36.9 VDC Externally applied 36V -0.5 to 47.1 VDC Externally applied 48V -0.5 to 62.9 VDC Externally applied MODULE INPUT SPECIFICATIONS MODULE OUTPUT SPECIFICATIONS Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474. Parameter Min Typ Max Unit Baseplate to sink; flat, greased surface 0.16 °C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.14 °C/Watt Baseplate to ambient 8.0 °C/Watt Baseplate to ambient; 1000 LFM 1.9 °C/Watt Thermal capacity 83 Watt-sec/°C THERMAL RESISTANCE AND CAPACITY Module Family Electrical Characteristics
24V Mini Family Rev 4.9 vicorpower.com Page 3 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Remote sense (total drop) 0.5 VDC 0.25V per leg (sense leads must be connected to respective, output terminals) Isolation test voltage (in to out)* 3000 VRMS Complies with reinforced insulation requirements Isolation test voltage (in to base)* 1500 VRMS Complies with basic insulation requirements Isolation test voltage (out to base)* 500 VRMS Complies with operational insulation requirements Isolation resistance 10 MΩ in to out, in to baseplate, out to baseplate Weight (E, C, T grade) 3.1 3.5 3.9 ounces Weight (H, M grade) 3.5 3.9 4.3 ounces Temperature limiting 100 115 °C See Figs. 3 and 5. Do not operate coverter >100C. Agency approvals cURus, cTÜVus, CE UL60950-1, EN60950-1, CSA60950-1, IEC60950-1. With appropriate fuse in series with the +Input Parameter Min Typ Max Unit Notes Primary Side (PC = Primary Control; PR = Parallel) PC bias voltage 5.50 5.75 6.00 VDC PC current = 1.0mA current limit 1.5 2.1 3.0 mA PC voltage = 5.5V During normal operation PC module enable delay 4 7 ms PC module alarm 0.5 Vavg UV, OV, OT, module fault. See Figs. 3 and 5 PC resistance 0.9 1.0 1.1 MΩ See Fig. 3, converter off or fault mode PR emitter amplitude 5.7 5.9 6.1 Volts PR load >30Ω, <30pF PR emitter current 150 mA PR receiver impedance 375 500 625 Ω 25°C PR receiver threshold 2.4 2.5 2.6 Volts Minimum pulse width: 20ns PR drive capability 12 modules Without PR buffer amplifier Secondary Side (SC = Secondary Control) SC bandgap voltage 1.21 1.23 1.25 VDC Referenced to –Sense SC resistance 990 1000 1010 Ω SC capacitance 0.033 µF SC module alarm 0 VDC With open trim; referenced to –Sense. See Fig. 7 MODULE CONTROL SPECIFICATIONS MODULE GENERAL SPECIFICATIONS * Isolation test voltage, 1 minute or less. Note: Specifications are subject to change without notice. Module Family Electrical Characteristics (Cont.)
24V Mini Family Rev 4.9 vicorpower.com Page 4 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency S24B3V3C100BL (enhanced efficiency) 83.5 85.1 % Nominal input; full load; 25°C V24B3V3C100BL (standard efficiency) 80.4 81.4 Ripple and noise 71 89 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 2.5 3 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 30.3 Amps Current limit 30.9 34.8 41 Amps Output voltage 95% of nominal Short circuit current 21.2 34.8 41 Amps Output voltage <250mV 3.3VOUT, 100W (e.g. S24B3V3C100BL, V24B3V3C100BL) Parameter Min Typ Max Unit Notes Efficiency S24B3V3C150BL (enhanced efficiency) 84.0 86.5 % Nominal input; full load; 25°C V24B3V3C150BL (standard efficiency) 80.0 81.4 Ripple and noise 160 200 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 5 6 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 45.45 Amps Current limit 46.4 52.3 61.5 Amps Output voltage 95% of nominal Short circuit current 31.8 52.3 61.5 Amps Output voltage <250mV 3.3VOUT, 150W (e.g. S24B3V3C150BL, V24B3V3C150BL) Parameter Min Typ Max Unit Notes Efficiency S24B5C150BL (enhanced efficiency) 86.0 87.2 % Nominal input; full load; 25°C V24B5C150BL (standard efficiency) 83.5 84.8 Ripple and noise 50 63 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 6.03 6.25 6.47 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 3.7 4.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 30 Amps Current limit 30.6 34.5 40.5 Amps Output voltage 95% of nominal Short circuit current 5 34.5 40.5 Amps Output voltage <250mV 5VOUT, 150W (e.g. S24B5C150BL, V24B5C150BL) Parameter Min Typ Max Unit Notes Efficiency S24B5C200BL (enhanced efficiency) 85.9 87.0 % Nominal input; full load; 25°C V24B5C200BL (standard efficiency) 80.5 84.9 Ripple and noise 95 119 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 6.07 6.3 6.53 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 5.1 5.5 Watts No load Load regulation ±0.02 ±0.45 % No load to full load; nominal input Load current 0 40 Amps Current limit 40.8 52 54.5 Amps Output voltage 95% of nominal Short circuit current 28 52 62 Amps Output voltage <250mV 5VOUT, 200W (e.g. S24B5C200BL, V24B5C200BL) MODULE SPECIFIC OPERATING SPECIFICATIONS
24V Mini Family Rev 4.9 vicorpower.com Page 5 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency S24B12C200BL (enhanced efficiency) 87.0 90.0 % Nominal input; full load; 25°C V24B12C200BL (standard efficiency) 87.0 88.0 Ripple and noise 360 450 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 13.8 14.4 15 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.6 7.4 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 16.67 Amps Current limit 17 19.2 22.6 Amps Output voltage 95% of nominal Short circuit current 11.6 19.2 22.6 Amps Output voltage <250mV 12VOUT, 200W (e.g. S24B12C200BL, V24B12C200BL) Parameter Min Typ Max Unit Notes Efficiency S24B8C200BL (enhanced efficiency) 87.0 89.0 % Nominal input; full load; 25°C V24B8C200BL (standard efficiency) 85.0 86.4 Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 9.36 9.7 10.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 5 6 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 25 Amps Current limit 25.5 28.8 33.8 Amps Output voltage 95% of nominal Short circuit current 17.5 28.8 33.8 Amps Output voltage <250mV 8VOUT, 200W (e.g. S24B8C200BL, V24B8C200BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency S24B6V5C200BL (enhanced efficiency) 84.5 87.5 % Nominal input; full load; 25°C V24B6V5C200BL (standard efficiency) 83.2 84.6 Ripple and noise 182 230 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 7.7 8.0 8.3 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 5.3 6.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 30.8 Amps Current limit 31.4 35.4 41.5 Amps Output voltage 95% of nominal Short circuit current 21.5 35.4 41.5 Amps Output voltage <250mV 6.5VOUT, 200W (e.g. S24B6V5C200BL, V24B6V5C200BL) Parameter Min Typ Max Unit Notes Efficiency S24B12C250BL (enhanced efficiency) 87.0 89.0 % Nominal input; full load; 25°C V24B12C250BL (standard efficiency) 86.0 87.4 Ripple and noise 172 215 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 13.8 14.3 14.8 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.5 7.6 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 20.8 Amps Current limit 21.3 24.0 28.1 Amps Output voltage 95% of nominal Short circuit current 14.6 24.0 28.1 Amps Output voltage <250mV 12VOUT, 250W (e.g. S24B12C250BL, V24B12C250BL)
24V Mini Family Rev 4.9 vicorpower.com Page 6 of 15 01/2016 800 927.9474 24V Input MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency 86.0 87.0 % Nominal input; full load; 25°C Ripple and noise 300 360 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 7.7 9.0 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 10.4 Amps Current limit 10.6 12.0 14.1 Amps Output voltage 95% of nominal Short circuit current 7.3 12.0 14.1 Amps Output voltage <250mV 24VOUT, 250W (e.g. V24B24C250BL) Parameter Min Typ Max Unit Notes Efficiency 88.0 88.9 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.4 5.4 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 10 Amps Current limit 10.2 11.5 13.5 Amps Output voltage 95% of nominal Short circuit current 7 11.5 13.5 Amps Output voltage <250mV 15VOUT, 150W (e.g. V24B15C150BL) Parameter Min Typ Max Unit Notes Efficiency 88.0 88.9 % Nominal input; full load; 25°C Ripple and noise 250 313 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 3.4 3.8 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 13.33 Amps Current limit 13.5 15.9 17.3 Amps Output voltage 95% of nominal Short circuit current 13.5 16.1 17.3 Amps Output voltage <250mV 15VOUT, 200W (e.g. V24B15C200BL) Parameter Min Typ Max Unit Notes Efficiency S24B12C150BL (enhanced efficiency) 87.5 90.0 % Nominal input; full load; 25°C V24B12C150BL (standard efficiency) 87.0 88.6 Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.5 5.4 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 12.5 Amps Current limit 12.7 14.4 16.9 Amps Output voltage 95% of nominal Short circuit current 8.75 14.4 16.9 Amps Output voltage <250mV 12VOUT, 150W (e.g. S24B12C150BL, V24B12C150BL)
24V Mini Family Rev 4.9 vicorpower.com Page 7 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency 86.5 87.7 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.7 5.1 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 6.25 Amps Current limit 6.37 7.19 8.44 Amps Output voltage 95% of nominal Short circuit current 3 7.19 8.44 Amps Output voltage <250mV 24VOUT, 150W (e.g. V24B24C150BL) Parameter Min Typ Max Unit Notes Efficiency 87.2 88.7 % Nominal input; full load; 25°C Ripple and noise 133 166 mV p-p Nominal input; full load; 20MHz bandwidth Output OVP setpoint 31.5 32.7 33.8 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 9.6 10.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 8.9 Amps Current limit 9.1 10.3 12.1 Amps Output voltage 95% of nominal Short circuit current 6.3 10.3 12.1 Amps Output voltage <250mV 28VOUT, 250W (e.g. V24B28C250BL) Parameter Min Typ Max Unit Notes Efficiency 85.0 87.0 % Nominal input; full load; 25°C Ripple and noise 180 225 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 31.6 32.8 34 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.5 5.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 7.14 Amps Current limit 7.29 8.22 9.66 Amps Output voltage 95% of nominal Short circuit current 5 8.22 9.66 Amps Output voltage <250mV 28VOUT, 200W (e.g. V24B28C200BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency 85.4 87.0 % Nominal input; full load; 25°C Ripple and noise 260 325 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 27.5 28.5 29.5 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 5.1 6.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 8.33 Amps Current limit 8.46 9.8 11.5 Amps Output voltage 95% of nominal Short circuit current 5.81 9.8 11.5 Amps Output voltage <250mV 24VOUT, 200W (e.g. V24B24C200BL)
24V Mini Family Rev 4.9 vicorpower.com Page 8 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency 87.6 89.1 % Nominal input; full load; 25°C Ripple and noise 182.0 228.0 mV p-p Nominal input; full load; 20MHz bandwidth Output OVP setpoint 53.8 55.7 57.6 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 7.4 8.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 5.2 Amps Current limit 5.3 6.0 7.0 Amps Output voltage 95% of nominal Short circuit current 3.6 6.0 7.0 Amps Output voltage <250mV 48VOUT, 250W (e.g. V24B48C250BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency 86.7 88.0 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.2 5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 4.17 Amps Current limit 4.25 4.8 5.63 Amps Output voltage 95% of nominal Short circuit current 2.91 4.8 5.63 Amps Output voltage <250mV 36VOUT, 150W (e.g. V24B36C150BL) Parameter Min Typ Max Unit Notes Efficiency 87.0 88.0 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.5 5.3 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 5.55 Amps Current limit 5.67 6.39 7.51 Amps Output voltage 95% of nominal Short circuit current 3.89 6.39 7.51 Amps Output voltage <250mV 36VOUT, 200W (e.g. V24B36C200BL) Parameter Min Typ Max Unit Notes Efficiency 86.5 87.8 % Nominal input; full load; 25°C Ripple and noise 200 250 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 4.3 5.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 5.36 Amps Current limit 5.46 6.16 7.24 Amps Output voltage 95% of nominal Short circuit current 3.75 6.16 7.24 Amps Output voltage <250mV 28VOUT, 150W (e.g. V24B28C150BL)
24V Mini Family Rev 4.9 vicorpower.com Page 9 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency 87.9 88.9 % Nominal input; full load; 25°C Ripple and noise 125 157 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 53.7 55.7 57.7 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 3.7 4.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 3.13 Amps Current limit 3.19 3.6 4.23 Amps Output voltage 95% of nominal Short circuit current 2.19 3.6 4.33 Amps Output voltage <250mV 48VOUT, 150W (e.g. V24B48C150BL) Parameter Min Typ Max Unit Notes Efficiency 86.0 87.5 % Nominal input; full load; 25°C Ripple and noise 225 282 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 53.8 55.8 57.8 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 5.4 5.8 Watts No load Load regulation ±0.02 ±0.5 % No load to full load; nominal input Load current 0 4.17 Amps Current limit 4.25 4.8 5.63 Amps Output voltage 95% of nominal Short circuit current 2.91 4.8 5.63 Amps Output voltage <250mV 48VOUT, 200W (e.g. V24B48C200BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24V Mini Family Rev 4.9 vicorpower.com Page 10 of 15 01/2016 800 927.9474 24V Input +IN PC PR –IN +OUT SC –OUT C3* 4.7nF C2* 4.7nF For C1 – C5, keep leads and connections short. C5* 4.7nF C4* 4.7nF F1* C1* 0.2µF Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide. Basic Module Operation Comprehensive Online Application Information The Design Guide and Applications Manual includes:
- Application circuits
- Design requirements
- EMC considerations
- Current sharing in power arrays
- Thermal performance information
- Recommended soldering methods
- Accessory modules – filtering, rectification, front-ends
- Mounting options
- ...and more. Also at vicorpower.com
- PowerBench online configurators
- Over 20 Application Notes
- Online calculators – thermal, trimming, hold-up
- PDF data sheets for ALL Vicor products CLICK HERE TO VIEW DESIGN GUIDE
24V Mini Family Rev 4.9 vicorpower.com Page 11 of 15 01/2016 800 927.9474 24V Input Disable Disable = PC <2.3V +Out SC –Out +In PC PR –In Figure 2 — Module enable/disable +OUT SC – OUT +IN PC PR –IN Input Undervoltage 2-20 ms typ. f (VIN) Auto Restart
5.7 Vdc
(0-3 mA) 50 Ω SW2 SW3 1.23 Vdc 6 K 1 K SW1 SW1, 2, & 3 shown in "Fault" position Input Overvoltage (See Note 1) Overtemperature Module Faults
1 Not applicable for 300 Vdc input family
Figure 3 — PC/SC module alarm logic Figure 4 — LED on-state indicator 4kΩ "Module Enabled" +Out SC –Out +In PC PR –In 2–20 ms typ. Fault SC PC 1.23 V 5.7 V 40 μs typ. Figure 5 — PC/SC module alarm timing Optocoupler +Out SC –Out +In PC PR –In 4 k/uni03A9 Alarm 1.00V +Out SC –Out +In PC PR –In Figure 6 — Isolated on-state indicator Figure 7 — Secondary side on-state indicator Module Enable/Disable The module may be disabled by pulling PC to 0V (2.3V max) with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes for 2 or more converters. See Figure 2. Primary Auxiliary Supply During normal operation only, the PC Pin can source 5.7V @ 1.5mA. In the example shown in Figure 4, PC powers a module enabled LED. Module Alarm The module contains “watchdog” circuitry which monitors input voltage, operating temperature and internal operating parame- ters. In the event that any of these parameters are outside of their allowable operating range, the module will shut down and PC will go low. PC will periodically go high and the module will check to see if the fault (as an example, Input Undervoltage) has cleared. If the fault has not been cleared, PC will go low again and the cycle will restart. The SC pin will go low in the event of a fault and return to its normal state after the fault has been cleared. See Figures 3 and 5. Primary Control - PC PIN
24V Mini Family Rev 4.9 vicorpower.com Page 13 of 15 01/2016 800 927.9474 24V Input Module 2 Module 1 Module N+1 +OUT SC –OUT Load +OUT SC –OUT +OUT SC –OUT Figure 11 — N+1 module array output connections
- The +Out and –Out power buses should be designed to minimize and balance parasitic impedance from each module output to the load.
- The +Sense pins must be tied together to form a +Sense bus. This must be Kelvin connected to +Out at a single point. The –Sense pins should be tied together to form a –Sense bus. This must be Kelvin connected to –Out at a single point.
- At the discretion of the power system designer, a subset of all modules within an array may be configured as slaves by connecting SC to –S.
- OR’ing diodes may be inserted in series with the +Out pins of each module to provide module output fault tolerance.
- The +Sense and -Sense leads should be routed in close proximity to each other on the printed circuit board. If wires are used to connect the converters on a PCB to an external load, the Sense leads should be twisted together to reduce noise pickup. Designator Description Finish Notes (None) Short Tin/Lead Requires in-board, mounting L Long Tin/Lead On-board mounting for 0.065” boards S Short ModuMate Gold SurfMate or in-board socket mounting N Long ModuMate Gold On-board socket mounting F Short RoHS Gold Select for RoHS compliant in-board solder, socket, or SurfMate mounting G Long RoHS Gold Select for RoHS compliant on-board solder or socket mounting K Extra Long RoHS Gold Select for RoHS compliance on-board mounting for thicker PCBs (not intended for socket or Surfmate mounting) * Pin style designator follows the “B” after the output power and precedes the baseplate designator. Ex. V24B12T250BN2 — Long ModuMate Pins Parallel Bus Output PIN STYLES*
24V Mini Family Rev 4.9 vicorpower.com Page 14 of 15 01/2016 800 927.9474 24V Input Mechanical Drawings PINS: TIN / LEAD HOT SOLDER DIPPED ALUMINUM BASEPLATE ALL MARKINGS THIS SURFACE NOTES: 1. MATERIAL: BASE: 6000 SERIES ALUMINUM COVER: LCP, ALUMINUM 3003 H14 PINS: R oHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS PINS: TIN/LEAD 90/10 BRIGHT 2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC 3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION DIMENSION L PIN SHORT – .55±.015 [14.0±.38] PIN EXTRA LONG–––- .71±.015 [18.0±.38] Figure 12 — Module outline 0.195 4,95 1.400* 35,56 1.000* 25,40 0.700* 17,78 0.400* 10,16 1.790** 45,470.06 1,5R (4X) 0.158 4,01 56789 12 34 ±0.003 ±0,08* DENOTES TOL = PCB THICKNESS 0.062 ±0.010 1,57 ±0,25 SHORT PIN STYLE 0.094 ±0.003 2,39 ±0,08 INBOARD SOLDER MOUNT 0.450.430.450.45 11,5 0.53 13,5 0.52 13,2 Requires Style 2 (Long) Pin 1.900* 48.26 1.900* 48,26 1.575 40,00 0.164 ±0.003 4,16 ±0,08 LONG PIN STYLE 0.094 ±0.003 2,39 ±0,08 ONBOARD SOLDER MOUNT 0.164 ±0.003 4,16 ±0,08 SOLDER PIN 0.094 ±0.003 2,39 ±0,08 ONBOARD SOLDER MOUNT 0.164 ±0.003 4,16 ±0,08 PLATED THROUGH HOLE DIA (7X) (2X) SOCKET HEADERS (SURFACE MOUNT) KIT INCLUDES INPUT & OUTPUT P/N 16021 INBOARD SOCKET MOUNT 0.46 11,7 SOCKET 0.183 ±0.003 4,65 ±0,08 ONBOARD SOCKET SURFACE MOUNT 0.56 14,2 SURFACE MOUNT N/A N/A SOCKETS 0.080" DIA. PINS (7X) P/N 13632 (100 pcs.) 0.150" DIA. PINS (2X) P/N 13633 (100 pcs.) P/N 16019 (9 pc. Kit) 0.266 ±0.003 6,76 ±0,08 Sockets and Standoffs are on hold as of 3-3-99 Sockets and Standoffs are staying the same as of 3-3-99 PCB WINDOW 0.45 SOLDER MOUNT SOCKET MOUNT OPTIONAL (2X) * ±0,08 ±DENOTES TOL= 0.003** 4312 98 76 5 (9X) PLATED THROUGH HOLE DIA PCB Mounting Specifications 0.400 10,16 0.700 17,78 1.000 25,40 1.400 35,56 1.900 48,26 FULL R (6X) (6X) (REF.) 0.10 2,5 2.000 50,80 1.30 33,0 2.28 57,9 2.20 55,9 0.130 3,30 0.10 2,5 0.49 12,4 0.65 16,5 0.06 1,5R( 3X) ALL MARKINGS THIS SURFACE X 45˚ CHAMFER Use a 4-40 Screw (6X) Torque to: 5 in-lbs
0.57 N-m
SOLDER:TIN / LEAD PLATED MODUMATE: GOLD PLATED COPPER RoHS: GOLD PLATED COPPER ALUMINUM BASEPLATE (2X) 0.01 0.35 8,8 0.20** 5,1 0.12* 3,1 DIA,(7X) 0.150 3,81 (REF) DIA,(2X) 0.080 2,03 431 76 5 0.23 5,8 0.400 10,16 1.400 35,56 1.000 25,40 0.700 17,78 2.20 55,9 1.76 44,7 0.54 13,7 0.43 10,9 Pin Style 2&N (Long Pin) 0.62 15,7 Pin Style 1&S (Short Pin) (9X) (9X) (ALL MARKINGS THIS SURFACE) ALUMINUM BASEPLATE 0.50 ±0.02 12,7 ±0,5 * Style 1 baseplate only Style 2 & 3 baseplates * Reserved for Vicor accessories Not for mounting Pin center line style 2 & 3 baseplates only (4X)*** 0.300 ±0.015 7,62 ±0,38 0.300 ±0.015 7,62 ±0,38 1.900 48,26 Pin C L C L Slotted Threaded 4-40 UNC-2B (6X) Thru Hole #30 Drill Thru (6X) (0.1285) 0.13 3,3 FULL R (6X) (6X) Pin Style K (Extra Long Pin) 0.71 18,0 (9X) NOTES: 1. MATERIAL: BASE: 6000 SERIES ALUMINUM COVER: LCP, ALUMINUM 3003 H14 PINS: R oHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS PINS: TIN/LEAD 90/10 BRIGHT 2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC 3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION For Soldering Methods and Procedures Please refer to: THE MAXI, MINI, MICRO Design Guide. Figure 13 — PCB mounting specifications Converter Pins No. Function Label 1 +In +
2 Primary PC Control
3 Parallel PR
4 –In – 5 –Out – 6 –Sense –S
7 Secondary SC Control
Unless otherwise specified, dimensions are in inches mm Decimals Tol. Angles 0.XX ±0.01 ±0.25 ±1° 0.XXX ±0.005 ±0.127
24V Mini Family Rev 4.9 vicorpower.com Page 15 of 15 01/2016 800 927.9474 24V Input Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and ac- cessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DIS- CLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat- ing safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com