24V Maxi Family Rev 6.6 vicorpower.com Page 1 of 15 01/2016 800 927.9474 24V Input Maxi Family Actual size: 4.6 x 2.2 x 0.5in 117 x 56 x 12,7mm S NRTLCU SC US Features & Benefits
- DC input range: 18 – 36V
- Isolated output
- Operation to 16V at 75% power after startup
- Input surge withstand: 50V for 100ms
- DC output: 3.3 – 48V
- Programmable output: 10 to 110%
- Regulation: ±0.25% no load to full load
- Efficiency: Up to 88%
- Maximum operating temp: 100°C, full load
- Power density: up to 99W per cubic inch
- Height above board: 0.43in. (10,9mm)
- Parallelable, with N+M fault tolerance
- Low noise ZCS/ZVS architecture
- RoHS Compliant (with F or G pin option) Product Overview These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Parameter Rating Unit Notes +In to –In voltage -0.5 to +53 VDC PC to –In voltage -0.5 to +7.0 VDC PR to –In voltage -0.5 to +7.0 VDC SC to -Out voltage -0.5 to +1.5 VDC -Sense to -Out voltage 1.0 VDC +Out to -Out, +Sense to -Out See Module Output Specifications Isolation voltage in to out 3000 VRMS Test voltage in to base 1500 VRMS Test voltage out to base 500 VRMS Test voltage Operating Temperature -55 to +100 °C M-Grade Storage Temperature -65 to +125 °C M-Grade Pin soldering temperature 500 (260) °F (°C) <5 sec; wave solder 750 (390) °F (°C) <7 sec; hand solder Mounting torque 5 (0.57) in-lbs (N-m) 6 each Output Power VOUT POUT 3.3V 200W, 264W 5V 300W, 400W 6.5V 400W 8V 300W 12V 300W, 400W, 500W 15V 300W, 400W 24V 300W, 400W, 500W 28V 300W, 400W, 500W 36V 300W, 400W 48V 300W, 400W Absolute Maximum Ratings Part Numbering e.g. V24A12T400BL2 24A B Output Voltage 3V3 = 3.3V 5 = 5V 6.5 = 6.5V 8 = 8V 12 = 12V 15 = 15V 24 = 24V 28 = 28V 36 = 36V 48 = 48V Product Grade Temperatures (°C) Grade Operating Storage E = -10 to +100 -20 to +125 C = -20 to +100 -40 to +125 T = -40 to +100 -40 to +125 H = -40 to +100 -55 to +125 M = -55 to +100 -65 to +125 Pin Style Finish Blank: Short Tin/Lead L: Long Tin/Lead S: Short ModuMate Gold N: Long ModuMate Gold F: Short RoHS Gold G: Long RoHS Gold K: Extra Long RoHS Gold Baseplate Blank: Slotted 2: Threaded 3: Through-hole Product Type V = Standard S = Enhanced efficiency (avail. ≤12 Vout only)
Applications
Industrial and process control, distributed power, medical, ATE, communications, defense and aerospace. For details on proper operation please refer to the: Design Guide & Applications Manual for Maxi, Mini, Micro Family.
24V Maxi Family Rev 6.6 vicorpower.com Page 2 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Operating input voltage 18 24 36 VDC These modules will operate at up to 75% of rated power down to 16VIN after start up at >18VIN Input surge withstand 50 VDC <100ms Undervoltage turn-on 17.5 17.9 VDC Undervoltage turn-off 14.8 15.3 VDC Overvoltage turn-off/on 36.3 37.8 39.6 VDC Disabled input current 4.0 mA PC pin low Parameter Min Typ Max Unit Notes Output voltage setpoint ±1% VOUT nom Nominal input; full load; 25°C Line regulation ±0.02 ±0.20 % Low line to high line; full load Temperature regulation ±0.002 ±0.005 % / °C Over operating temperature range Power sharing accuracy ±2 ±5 % 10 to 100% of full load Of nominal output voltage. For trimming below 90% Programming range 10 110 % of nominal, a minimum load of 10% of maximum rated power may be required. +Out to -Out, +Sense to -Out – Absolute Maximum Ratings 3.3V -0.5 to 4.7 VDC Externally applied 5V -0.5 to 7.0 VDC Externally applied 6.5V -0.5 to 9.0 VDC Externally applied 8V -0.5 to 10.9 VDC Externally applied 12V -0.5 to 16.1 VDC Externally applied 15V -0.5 to 20.0 VDC Externally applied 24V -0.5 to 31.7 VDC Externally applied 28V -0.5 to 36.9 VDC Externally applied 36V -0.5 to 47.2 VDC Externally applied 48V -0.5 to 62.9 VDC Externally applied MODULE INPUT SPECIFICATIONS MODULE OUTPUT SPECIFICATIONS Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474. Parameter Min Typ Max Unit Baseplate to sink; flat, greased surface 0.08 °C/Watt Baseplate to sink; thermal pad (P/N 20263) 0.07 °C/Watt Baseplate to ambient 4.9 °C/Watt Baseplate to ambient; 1000 LFM 1.1 °C/Watt Thermal capacity 165 Watt-sec/°C THERMAL RESISTANCE AND CAPACITY Module Family Electrical Characteristics
24V Maxi Family Rev 6.6 vicorpower.com Page 3 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Primary Side (PC = Primary Control; PR = Parallel) PC bias voltage 5.50 5.75 6.00 VDC PC current = 1.0mA current limit 1.5 2.1 3.0 mA PC voltage = 5.5V During normal operation PC module enable delay 4 7 ms PC module alarm 0.5 Vavg UV, OV, OT, module fault. See Figs. 3 and 5 PC resistance 0.9 1.0 1.1 MΩ See Fig. 3, converter off or fault mode PR emitter amplitude 5.7 5.9 6.1 Volts PR load >30Ω, <30pF PR emitter current 150 mA PR receiver impedance 375 500 625 Ω 25°C PR receiver threshold 2.4 2.5 2.6 Volts Minimum pulse width: 20ns PR drive capability 12 modules Without PR buffer amplifier Secondary Side (SC = Secondary Control) SC bandgap voltage 1.21 1.23 1.25 VDC Referenced to –Sense SC resistance 990 1000 1010 Ω SC capacitance 0.033 µF SC module alarm 0 VDC With open trim; referenced to –Sense. See Fig. 7 MODULE CONTROL SPECIFICATIONS MODULE GENERAL SPECIFICATIONS Module Family Electrical Characteristics (Cont.) * Isolation test voltage, 1 minute or less. Note: Specifications are subject to change without notice. Parameter Min Typ Max Unit Notes Remote sense (total drop) 0.5 VDC 0.25V per leg (sense leads must be connected to respective, output terminals) Isolation test voltage (in to out)* 3000 VRMS Complies with reinforced insulation requirements Isolation test voltage (in to base)* 1500 VRMS Complies with basic insulation requirements Isolation test voltage (out to base)* 500 VRMS Complies with operational insulation requirements Isolation resistance 10 MΩ in to out, in to baseplate, out to baseplate Weight (E, C, T grade) 6.5 7.3 8.1 ounces Weight (H, M grade) 7.4 8.2 9.0 ounces Temperature limiting 100 115 °C See Figs. 3 and 5. Do not operate coverter >100C. Agency approvals cURus, cTÜVus, CE UL60950-1, EN60950-1, CSA60950-1, IEC60950-1. With appropriate fuse in series with the +Input
24V Maxi Family Rev 6.6 vicorpower.com Page 4 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency S24A3V3C264BL (enhanced efficiency) 83.0 86.0 % Nominal input; full load; 25°C V24A3V3C264BL (standard efficiency) 80.0 81.4 Ripple and noise 75 94 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 8 12 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 80 Amps Current limit 81.6 92 108 Amps Output voltage 95% of nominal Short circuit current 56 92 108 Amps Output voltage <250mV 3.3VOUT, 264W (e.g. S24A3V3C264BL, V24A3V3C264BL) Parameter Min Typ Max Unit Notes Efficiency S24A3V3C200BL (enhanced efficiency) 82.0 86.0 % Nominal input; full load; 25°C V24A3V3C200BL (standard efficiency) 73.9 79.9 Ripple and noise 43 54 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 4.48 4.65 4.82 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.2 10 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 60.6 Amps Current limit 61.8 69.7 81.9 Amps Output voltage 95% of nominal Short circuit current 42.4 69.7 81.9 Amps Output voltage <250mV 3.3VOUT, 200W (e.g. S24A3V3C200BL, V24A3V3C200BL) Parameter Min Typ Max Unit Notes Efficiency S24A5C400BL (enhanced efficiency) 84.0 86.5 % Nominal input; full load; 25°C V24A5C400BL (standard efficiency) 80.0 84.5 Ripple and noise 152 190 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 6.03 6.25 6.47 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.8 10.1 Watts No load Load regulation ±0.02 ±0.25 % No load to full load; nominal input Load current 0 80 Amps Current limit 81.6 92 104 Amps Output voltage 95% of nominal Short circuit current 56 92 104 Amps Output voltage <250mV 5VOUT, 400W (e.g. S24A5C400BL, V24A5C400BL) Parameter Min Typ Max Unit Notes Efficiency S24A5C300BL (enhanced efficiency) 82.5 84.4 % Nominal input; full load; 25°C V24A5C300BL (standard efficiency) 82.5 84.4 Ripple and noise 120 150 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 6.03 6.25 6.47 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 7.2 8.8 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 60 Amps Current limit 61.2 69 81 Amps Output voltage 95% of nominal Short circuit current 42 69 81 Amps Output voltage <250mV 5VOUT, 300W (e.g. S24A5C300BL, V24A5C300BL) MODULE SPECIFIC OPERATING SPECIFICATIONS
24V Maxi Family Rev 6.6 vicorpower.com Page 5 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency S24A6V5C400BL (enhanced efficiency) 85.0 86.1 % Nominal input; full load; 25°C V24A6V5C400BL (standard efficiency) 85.0 86.1 Ripple and noise 220 275 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 7.7 7.98 8.26 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 9.2 10.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Output Current 0 61.5 Amps Current limit 62.7 70.7 83.1 Amps Output voltage 95% of nominal Short circuit current 43 70.7 83.1 Amps Output voltage <250mV 6.5VOUT, 400W (e.g. S24A6V5C400BL, V24A6V5C400BL) Parameter Min Typ Max Unit Notes Efficiency S24A8C300BL (enhanced efficiency) 85.6 86.5 % Nominal input; full load; 25°C V24A8C300BL (standard efficiency) 85.6 86.5 Ripple and noise 215 269 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 9.36 9.7 10.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 8.7 13.9 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 37.5 Amps Current limit 38.2 43.1 50.7 Amps Output voltage 95% of nominal Short circuit current 26.2 43.1 50.7 Amps Output voltage <250mV 8VOUT, 300W (e.g. S24A8C300BL, V24A8C300BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency S24A12C400BL (enhanced efficiency) 86.0 89.5 % Nominal input; full load; 25°C V24A12C400BL (standard efficiency) 87.0 88.3 Ripple and noise 250 320 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.8 10.2 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 33.33 Amps Current limit 34 38.4 43.5 Amps Output voltage 95% of nominal Short circuit current 23.3 38.4 43.5 Amps Output voltage <250mV 12VOUT, 400W (e.g. S24A12C400BL, V24A12C400BL) Parameter Min Typ Max Unit Notes Efficiency S24A12C500B (enhanced efficiency) 86.7 88.2 % Nominal input; full load; 25°C V24A12C500BL (standard efficiency) 86.0 87.5 Ripple and noise 272 340 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 13.8 14.3 14.8 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 10.8 12.0 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 41.67 Amps Current limit 42.5 47.9 56.3 Amps Output voltage 95% of nominal Short circuit current 29.2 47.9 56.3 Amps Output voltage <250mV 12VOUT, 500W (e.g. S24A12C500B, V24A12C500BL)
24V Maxi Family Rev 6.6 vicorpower.com Page 6 of 15 01/2016 800 927.9474 24V Input MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency 87.3 88.3 % Nominal input; full load; 25°C Ripple and noise 172 215 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 11.9 19.1 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 20.83 Amps Current limit 21.3 24.0 28.1 Amps Output voltage 95% of nominal Short circuit current 14.6 24.0 28.1 Amps Output voltage <250mV 24VOUT, 500W (e.g. V24A24C500BL) Parameter Min Typ Max Unit Notes Efficiency 85.0 86.2 % Nominal input; full load; 25°C Ripple and noise 160 200 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 8.1 10 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 20 Amps Current limit 20.4 23 27 Amps Output voltage 95% of nominal Short circuit current 14 23 27 Amps Output voltage <250mV 15VOUT, 300W (e.g. V24A15C300BL) Parameter Min Typ Max Unit Notes Efficiency 88.0 89.0 % Nominal input; full load; 25°C Ripple and noise 60 75 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.3 9.4 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 26.67 Amps Current limit 27.2 30.7 34.8 Amps Output voltage 95% of nominal Short circuit current 18.6 30.7 37.9 Amps Output voltage <250mV 15VOUT, 400W (e.g. V24A15C400BL) Parameter Min Typ Max Unit Notes Efficiency S24A12C300BL (enhanced efficiency) 88.0 89.5 % Nominal input; full load; 25°C V24A12C300BL (standard efficiency) 87.0 88.2 Ripple and noise 196 245 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.9 8.6 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 25 Amps Current limit 25.5 28.8 33.8 Amps Output voltage 95% of nominal Short circuit current 17.5 28.8 33.8 Amps Output voltage < 250mV 12VOUT, 300W (e.g. S24A12C300BL, V24A12C300BL)
24V Maxi Family Rev 6.6 vicorpower.com Page 7 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency 86.0 87.8 % Nominal input; full load; 25°C Ripple and noise 172 215 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 6.3 9.5 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 14.29 Amps Current limit 14.5 16.4 19.4 Amps Output voltage 95% of nominal Short circuit current 10 16.4 19.4 Amps Output voltage <250mV 28VOUT, 400W (e.g. V24A28C400BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency 86.8 88.2 % Nominal input; full load; 25°C Ripple and noise 85 107 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 7.8 10 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 12.5 Amps Current limit 12.7 14.4 16.9 Amps Output voltage 95% of nominal Short circuit current 8.75 14.4 16.9 Amps Output voltage <250mV 24VOUT, 300W (e.g. V24A24C300BL) Parameter Min Typ Max Unit Notes Efficiency 88.0 89.1 % Nominal input; full load; 25°C Ripple and noise 80 100 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 11 12 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 16.67 Amps Current limit 17 19.2 23.4 Amps Output voltage 95% of nominal Short circuit current 2.25 19.2 23.4 Amps Output voltage <250mV 24VOUT, 400W (e.g. V24A24C400BL) Parameter Min Typ Max Unit Notes Efficiency 86.0 88.0 % Nominal input; full load; 25°C Ripple and noise 172 215 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 13.5 14.8 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 17.9 Amps Current limit 18.3 20.6 24.2 Amps Output voltage 95% of nominal Short circuit current 12.5 20.6 24.2 Amps Output voltage <250mV 28VOUT, 500W (e.g. V24A28C500BL)
24V Maxi Family Rev 6.6 vicorpower.com Page 8 of 15 01/2016 800 927.9474 24V Input Parameter Min Typ Max Unit Notes Efficiency 87.0 88.0 % Nominal input; full load; 25°C Ripple and noise 100 125 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 7.1 9.3 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 10.71 Amps Current limit 10.9 12.3 14.5 Amps Output voltage 95% of nominal Short circuit current 3 12.3 14.5 Amps Output voltage <250mV 28VOUT, 300W (e.g. V24A28C300BL) Parameter Min Typ Max Unit Notes Efficiency 86.0 88.0 % Nominal input; full load; 25°C Ripple and noise 120 150 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 10 13 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 11.11 Amps Current limit 11.3 12.8 15 Amps Output voltage 95% of nominal Short circuit current 7.77 12.8 15 Amps Output voltage <250mV 36VOUT, 400W (e.g. V24A36C400BL) Parameter Min Typ Max Unit Notes Efficiency 87.0 88.3 % Nominal input; full load; 25°C Ripple and noise 80 100 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 9.8 12 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 8.33 Amps Current limit 8.49 9.58 11.3 Amps Output voltage 95% of nominal Short circuit current 5.83 9.58 11.3 Amps Output voltage <250mV 36VOUT, 300W (e.g. V24A36C300BL) Parameter Min Typ Max Unit Notes Efficiency 84.7 86.7 % Nominal input; full load; 25°C Ripple and noise 160 200 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 53.8 55.8 57.8 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 11.8 12.7 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 8.33 Amps Current limit 8.49 9.58 11.3 Amps Output voltage 95% of nominal Short circuit current 4.79 9.58 11.3 Amps Output voltage <250mV 48VOUT, 400W (e.g. V24A48C400BL) MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24V Maxi Family Rev 6.6 vicorpower.com Page 9 of 15 01/2016 800 927.9474 24V Input MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes Efficiency 86.0 87.1 % Nominal input; full load; 25°C Ripple and noise 180 225 mV p-p; Nominal input; full load; 20MHz bandwidth Output OVP setpoint 53.7 55.7 57.7 Volts 25°C; recycle input voltage or PC to restart (>100ms off) Dissipation, standby 7.7 10 Watts No load Load regulation ±0.02 ±0.2 % No load to full load; nominal input Load current 0 6.25 Amps Current limit 6.37 7.19 8.44 Amps Output voltage 95% of nominal Short circuit current 4.37 7.19 8.44 Amps Output voltage <250mV 48VOUT, 300W (e.g. V24A48C300BL)
24V Maxi Family Rev 6.6 vicorpower.com Page 10 of 15 01/2016 800 927.9474 24V Input +IN PC PR –IN +OUT SC –OUT C3* 4.7nF C2* 4.7nF For C1 – C5, keep leads and connections short. C5* 4.7nF C4* 4.7nF F1* C1* 0.2µF Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide. Basic Module Operation Comprehensive Online Application Information The Design Guide and Applications Manual includes:
- Application circuits
- Design requirements
- EMC considerations
- Current sharing in power arrays
- Thermal performance information
- Recommended soldering methods
- Accessory modules – filtering, rectification, front-ends
- Mounting options
- ...and more. Also at vicorpower.com
- PowerBench online configurators
- Over 20 Application Notes
- Online calculators – thermal, trimming, hold-up
- PDF data sheets for ALL Vicor products CLICK HERE TO VIEW DESIGN GUIDE
24V Maxi Family Rev 6.6 vicorpower.com Page 11 of 15 01/2016 800 927.9474 24V Input Module Enable/Disable The module may be disabled by pulling PC below 2.3V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes. See Figure 2. Primary Auxiliary Supply At 5.7V, PC can source up to 1.5mA. In the example shown in Figure 4, PC powers a module enabled LED. Module Alarm The module contains “watchdog” circuitry which monitors input voltage, operating temperature and internal operating parameters. In the event that any of these parameters are outside of their allowable operating range, the module will shut down and PC will go low. PC will periodically go high and the module will check to see if the fault (as an example, overtemperature) has cleared. If the fault has not been cleared, PC will go low again and the cycle will restart. The SC pin will go low in the event of a fault and return to its normal state after the fault has been cleared. See Figures 3 and 5. Primary Control - PC PIN +IN PC PR –IN Disable Disable = PC <2.3 V Figure 2 — Module enable/disable Figure 4 — LED on-state indicator +IN PC PR –IN 4 kΩ "Module Enabled" +IN PC PR –IN Optocoupler 4 kΩ Alarm 1.00V +OUT SC –OUT +IN PC PR –IN Comparator +OUT SC – OUT +IN PC PR –IN Input Undervoltage 2-20 ms typ. f (VIN) Auto Restart
5.7 Vdc
(0-3 mA) 50 Ω SW2 SW3 1.23 Vdc 6 K 1 K SW1 SW1, 2, & 3 shown in "Fault" position Input Overvoltage (See Note 1) Overtemperature Module Faults
1 Not applicable for 300 Vdc input family
Figure 3 — PC/SC module alarm logic Figure 6 — Isolated on-state indicator 2–20 ms typ. Fault SC PC 1.23 V 5.7 V 40 μs typ. Figure 5 — PC/SC module alarm timing Figure 7 — Secondary side on-state indicator
24V Maxi Family Rev 6.6 vicorpower.com Page 13 of 15 01/2016 800 927.9474 24V Input Module 2 Module 1 Module N+1 +OUT SC –OUT Load +OUT SC –OUT +OUT SC –OUT Figure 11 — N+1 module array output connections
- The +Out and –Out power buses should be designed to minimize and balance parasitic impedance from each module output to the load.
- The +Sense pins must be tied together to form a +Sense bus. This must be Kelvin connected to +Out at a single point. The –Sense pins should be tied together to form a –Sense bus. This must be Kelvin connected to –Out at a single point.
- At the discretion of the power system designer, a subset of all modules within an array may be configured as slaves by connecting SC to –S.
- OR’ing diodes may be inserted in series with the +Out pins of each module to provide module output fault tolerance.
- The +Sense and -Sense leads should be routed in close proximity to each other on the printed circuit board. If wires are used to connect the converters on a PCB to an external load, the Sense leads should be twisted together to reduce noise pickup. Designator Description Finish Notes (None) Short Tin/Lead Requires in-board, mounting L Long Tin/Lead On-board mounting for 0.065” boards S Short ModuMate Gold SurfMate or in-board socket mounting N Long ModuMate Gold On-board socket mounting F Short RoHS Gold Select for RoHS compliant in-board solder, socket, or SurfMate mounting G Long RoHS Gold Select for RoHS compliant on-board solder or socket mounting K Extra Long RoHS Gold Select for RoHS compliance on-board mounting for thicker PCBs (not intended for socket or Surfmate mounting) * Pin style designator follows the “B” after the output power and precedes the baseplate designator. Ex. V48A12T500BN2 — Long ModuMate Pins Parallel Bus Output PIN STYLES*
24V Maxi Family Rev 6.6 vicorpower.com Page 14 of 15 01/2016 800 927.9474 24V Input ALL MARKINGS THIS SURFACE PINS STYLES SOLDER:TIN/LEAD PLATED MODUMATE: GOLD PLATED COPPER RoHS: GOLD PLATED COPPER ALUMINUM BASEPLATE 0.195 4,95 1.400* 35,56 1.000* 25,40 0.700* 17,78 0.400* 10,16 3.844** 97,64 4.200* 106,68 1.790** 45,470.06 1,5R (4X) 0.178 4,52 56789 12 34 ±0.003 ±0,08* DENOTES TOL = PLATED THRU HOLE DIA PCB THICKNESS 0.062 ±0.010 1,57 ±0,25 SHORT PIN STYLE 0.094 ±0.003 2,39 ±0,08 0.194 ±0.003 4,93 ±0,08 LONG PIN STYLE 0.094 ±0.003 2,39 ±0,08 0.194 ±0.003 4,93 ±0,08 INBOARD SOLDER MOUNT 0.45 11,5 SOCKET HEADERS (SURFACE MOUNT) KIT INCLUDES INPUT & OUTPUT P/N 16017 ONBOARD SOLDER MOUNT (7X) (2X) ONBOARD SOCKET SURFACE MOUNT 0.56 14,2 SURFACE MOUNT N/A N/A INBOARD SOCKET MOUNT 0.46 11,7 SOCKET 0.183 ±0.003 4,65 ±0,08 0.266 ±0.003 6,76 ±0,08 SOCKETS 0.080" DIA. PINS (7X) P/N 13632 (100 pieces) 0.180" DIA. PINS (2X) P/N 13634 (100 pieces) KIT # 16015 INCLUDES (7X) 0.080" DIA. PINS & (2X) 0.180" DIA. PINS 0.53 13,5 **PCB WINDOW For Soldering Methods and Procedures Please refer to: THE MAXI, MINI, MICRO Design Guide. Mechanical Drawings NOTES: 1. MATERIAL: BASE: 6000 SERIES ALUMINUM PINS: RoHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS PINS: TIN/LEAD 90/10 BRIGHT 2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC 3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION DIMENSION L PIN SHORT – .55±.015 [14.0±.38] PIN EXTRA LONG–––- .71±.015 [18.0±.38] Figure 12 — Module outline Figure 13 — PCB mounting specifications Converter Pins No. Function Label 1 +In +
2 Primary PC Control
3 Parallel PR
4 –In – 5 –Out – 6 –Sense –S
7 Secondary SC Control
Unless otherwise specified, dimensions are in inches mm Decimals Tol. Angles 0.XX ±0.01 ±0.25 ±1° 0.XXX ±0.005 ±0.127
24V Maxi Family Rev 6.6 vicorpower.com Page 15 of 15 01/2016 800 927.9474 24V Input Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and ac- cessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Ex- press Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat- ing safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com