AC Variable Frequency Drives Type Variflex
3 RVLF Advance
Product Description Ordering Key Approvals Type Selection Variflex3 AC Drive Frame Size AC Supply Drive Voltage Rating Drive kW Rating Filter Advance Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 1
- AC variable frequency drive for use with AC induction motors
- V/F + Sensorless Vector (SLV)
- Input voltage ranges: 100-120V, 200-240V, 380-480V
- Conforms to EMC standard EN 61800-3
- PTC input provide motor temperature protection
- PID mode available on board
- Built-in Class A filter*
- DIN-rail or panel mounting
- Inbuilt BACNET communication
- Communication interface modules for Profibus/ DeviceNet/Ethernet (TCP/IP)/CANopen The RVLF is the economical and compact AC variable frequency drive for use with 3-phase AC induction motors. The drives have compact dimensions and can be installed side by side to save space. The full range of products covers various voltage ratings: single-phase 100V or 200V, as well as, three- phase 200V or 480V. The RVLF Advance comes with sensorless vector control as well as onboard BACnet communication. RVLF RVLF A 1 20 075 F A Frame Size AC Supply Phase Drive Voltage Rating Drive kW Rating Filter Advance A: Size 1 B: Size 2 C: Size 3 D: Size 4 1: 1-Phase 3: 3-Phase 10: 100-120VAC 20: 200-240VAC 40: 380-480VAC 040: 0.4kW, 0.5HP F: Built-in EMI filter A: Advance 075: 0.75kW, 1.0HP 150: 1.5kW, 2.0HP 220: 2.2kW, 3.0HP 370: 3.7kW, 5.0HP 550: 5.5kW, 7.5HP 750: 7.5kW, 10HP 1100: 11kW, 15HP
2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 Motor Controllers AC Variable Frequency Drives Type Variflex Model RVLFA110040A RVLFB110075A Horse power rating 0.5HP 1HP Nominal motor power 0.4kW 0.75kW Rated output current 2.6A 4.3A Rated capacity 1.00kVA 1.65kVA Input voltage range Single phase: 100~120VAC (+10% / -15%), 50/60HZ Output voltage range Three phase 0~240VAC Input current 13A 19A Allowable momentary power loss time 1.0 s 1.0 s Ingress protection class IP20 100V Class: Single phase Model RVLFA120040FA RVLFA120075FA RVLFB120150FA RVLFB120220FA Horse power rating 0.5HP 1HP 2HP 3HP Nominal motor power 0.4kW 0.75kW 1.5kW 2.2kW Rated output current 2.6A 4.3A 7.5A 10.5A Rated capacity 1.0kVA 1.65kVA 2.90kVA 4.0kVA Input voltage range Single phase: 200~240VAC (+10% / -15%), 50/60HZ Output voltage range Three phase 0~240VAC Input current 7.2A 11A 15.5A 21A Allowable momentary power loss time 1.0s 1.0s 2.0s 2.0s Ingress protection class IP20 200V Class: Single phase Selection Guide Voltage Rating AC Supply Phase Motor Rating Ordering Code 100 - 120VAC (+10% / -15%) 1-Phase 0.4kW 0.5HP RVLFA110040A 0.75kW 0.75HP RVLFA110075A 0.4kW 0.5HP RVLFA120040FA 0.75kW 0.75HP RVLFA120075FA 1.5kW 2.0HP RVLFB120150FA 2.2kW 3.0HP RVLFB120220FA 200-240VAC (+10%/-15%) 3 Phase 0.4kW 0.5HP RVLFA320040A 0.75kW 0.75HP RVLFA320075A 1.5kW 2.0HP RVLFB320150A 2.2kW 3.0HP RVLFB320220A 0.75kW 0.75HP RVLFB340075FA 1.5kW 2.0HP RVLFB340150FA 2.2kW 3.0HP RVLFB340220FA 3.7kW 5.0HP RVLFC340370FA 5.5kW 7.5HP RVLFC340550FA 7.5kW 10HP RVLFD340750FA 11kW 15HP RVLFD3401100FA
AC Variable Frequency Drives Type Variflex Input / Output Data cont. Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 3 Model RVLFB340075KW RVLFB340150FA RVLFB340220FA RVLFC340370FA Horse power rating 1HP 2HP 3HP 5HP Nominal motor power 0.75kW 1.5kW 2.2kW 3.7kW Rated output current 2.3A 3.8A 5.2A 9.2A Rated capacity 1.7kVA 2.9kVA 4.0kVA 7.01kVA Input voltage range Three phase: 380~480VAC (+10% / -15%), 50/60HZ Output voltage range Three phase 0~480VAC Input current 4.2A 5.6A 7.3A 10.1A Allowable momentary power loss time 2.0s 2.0s 2.0s 2.0s Ingress protection class IP20 400V Class: Three phase Environmental Data Installation Location Indoor (protected from corrosive gases and dust) Operating Temperature -10~+50°C / -14 ~+122°F Storage Temperature -20~+60°C / -4°~+140° F Humidity Under 95% RH (no condensation) Vibration 0.075mm Amplitude for 10Hz to 57Hz 1G for 57Hz to 150Hz EMC Compliance EN61800-3, first environment LVD Compliance EN61800-5-1 Ingress Protection Level IP20 Model RVLFA320040A RVLFA320075A RVLFB320150A RVLFB320220A Horse power rating 0.5HP 1HP 2HP 3HP Nominal motor power 0.4kW 0.75kW 1.5kW 2.2kW Rated output current 2.6A 4.3A 7.5A 10.5A Rated capacity 1.0kVA 1.65kVA 2.90kVA 4.0kVA Input voltage range Three phase: 200~240VAC (+10% / -15%), 50/60HZ Output voltage range Three phase 0~240VAC Input current 4A 6.4A 9.4A 12.2A Allowable momentary power loss time 1.0s 1.0s 2.0s 2.0s Ingress protection class IP20 200V Class: Three Phase Model RVLFC340550FA RVLFD340750FA RVLFD3401100FA Horse power rating 7.5HP 10HP 15HP Nominal motor power 5.5kW 7.5kW 11kW Rated output current 13.0A 17.5A 24A Rated capacity 9.91kVA 13.34kVA 18.29kVA Input voltage range Three phase: 380~480VAC (+10% / -15%), 50/60HZ Output voltage range Three phase 0~480VAC Input current 14.3A 19.3A 26.4A Allowable momentary power loss time 2.0s 2.0s 2.0s Ingress protection class IP20
4 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 Motor Controllers AC Variable Frequency Drives Type Variflex Control Mode V/F Control + SLV Control Frequency Range 0.01 ~ 599Hz. Speed accuracy (100% torque) V/F: 3% SLV: 1% Starting torque V/F: 3Hz / 100% SLV: 3Hz / 150% Setting resolution Digital input: 0.01Hz. Analog input: 0.015Hz/60Hz Setting • Keypad: Set directly with keys or the VR (potentiometer) on the keypad.
- External input terminals: AVI (0/2~10V), ACI (0/4~20mA) input. Multifunction input up/down function (Group3).
- Setting frequency by communication method. Frequency limit Lower and upper frequency limits, 3 skip-frequency settings. Run Operational settings • Keypad run, stop button.
- External terminals: Multi-operation-mode 2/3 wire selection jog operation.
- Run signal, by communication method. Drive Functions V/F curve setting 6 fixed curve and one customized curve. Carrier frequency 1~16KHz (default 5KHz). Acceleration and deceleration control 2 off Acc/Dec time parameters, 4 off S curve parameters. Multifunctional input 19 functions (refer to description on group3). Multifunctional output 16 functions (refer to description on group3). Multifunctional analog output 5 functions (refer to description on group4). Main Features Overload detection, 8 preset speeds, Auto-run, Acc/Dec switch (2 stages), Main/Alt run command select, Main/Alt frequency command select, PID control, torque boost, V/F start frequency, fault reset. Display 7 segment display (LED) Display: parameter/para- meter value/frequency/line speed/DC voltage/ output voltage/output current/PID feedback/input and output terminal status/ heat sink temperature/ program version/fault log. LED status Indicator For run/stop/forward and reverse. Protection Functions Overload protection Integrated motor and inverter overload protection. (150% rated current for 60sec, every 10 minutes) Over voltage 100V/200V: Over 410V, 400V: Over 820V. Under voltage 100V/200V: Under 190V, 400V: Under 380V. Momentary power loss restart Inverter auto-restart after a momentary power loss. Stall prevention Stall prevention for acceleration/deceleration/ and continuous run. Short-circuit output terminal Electronic circuit protection. Grounding fault Electronic circuit protection. Additional protective functions Heatsink over temperature protection, auto carrier frequency reduction with temperature rise, fault output, reverse prohibit, number of auto restart attempts, parameter lock, over voltage protection (OVP), motor PTC over- temperature protection. Internation Certification CE/cULus Communication RS485 (Modbus) built in, with one-to-one or one-to- many control. Built-in BacNet communication
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 5 Motor Controllers AC Variable Frequency Drives Type Variflex Model: Single Phase (NPN) 100V: RVLFA110040A, RVLFA110075A Model: Single Phase (PNP) 200V: RVLFA120040FA, RVLFA120075FA, RVLFB120150FA, RVLFB120220FA (MCCB L1(L) AC source AO 3 + 250VAC/1A (30VDC/1A) RB RA L3 (N) ON-OFF Surge Suppressor 10V AVI ACI GND MC Magnetic Contactor RS485 FWD (Run/Stop) REV (Run/Stop) Speed Control External speed potentiometer = 10 Kohm or PID input Induction Motor COM MC Thermal relay MC GND 0~10V 2 AO Frequency Indicator 0~10VDC CON2 Thermal relay M 0~20mA P P'2'1 Relay Output Pin 1 to Pin 8 Ground Inverter output Power input Analog Output Multifunction Input Terminals Analog Input 1:Data+ 2:Data- 3:Data+ 4:Reserved 5:Reserved 6:Data- 7:5V 8:GND (MCCB L1 (L) AC source AO 3 + 250VAC/1A (30VDC/1A) RB RA L3 (N) ON-OFF Surge Suppressor 10V AVI ACI GND MC Magnetic Contactor RS485 FWD (Run/Stop) REV (Run/Stop) Speed Control External speed potentiometer = 10 Kohm or PID input Induction Motor +24V MC Thermal relay MC GND 0~10V 2 AO Frequency Indicator 0~10VDC CON2 Thermal relay M 0~20mA P P'2'1 Relay Output Pin 1 to Pin 8 Ground Inverter output Power input Analog Output Multifunction Input Terminals Analog Input 1:Data+ 2:Data- 3:Data+ 4:Reserved 5:Reserved 6:Data- 7:5V 8:GND
AC Variable Frequency Drives Type Variflex Model: Three Phase (NPN) 200V: RVLFA320040A, RVLFA320075A, RVLFB320150A, RVLFB320220A Model: Three Phase (PNP) 400V: RVLFB340075FA, RVLFB340150FA, RVLFB340220FA Connection Diagrams cont. 6 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 (MCCB L1 (L) AC source AO 3 + 250VAC/1A (30VDC/1A) RB RA L3 (N) ON-OFF Surge Suppressor 10V AVI ACI GND MC Magnetic Contactor RS485 FWD (Run/Stop) REV (Run/Stop) Speed Control External speed potentiometer = 10 Kohm or PID input Induction Motor COM MC Thermal relay MC GND 0~10V 2 AO Frequency Indicator 0~10VDC CON2 Thermal relay M 0~20mA P P'2'1 Relay Output Pin 1 to Pin 8 Ground Inverter output Power input Analog Output Multifunction Input Terminals Analog Input 1:Data+ 2:Data- 3:Data+ 4:Reserved 5:Reserved 6:Data- 7:5V 8:GND (MCCB L1(L) AC source AO 3 + 250VAC/1A (30VDC/1A) RB RA L3(N) ON-OFF Surge Suppressor 10V AVI ACI GND MC Magnetic Contactor RS485 FWD (Run/Stop) REV (Run/Stop) Speed Control External speed potentiometer = 10 Kohm or PID input Induction Motor +24V MC Thermal relay MC GND 0~10V 2 AO Frequency Indicator 0~10VDC CON2 Thermal relay M 0~20mA P P'2'1 Relay Output Pin 1 to Pin 8 Ground Inverter output Power input Analog Output Multifunction Input Terminals Analog Input P BR 1:Data+ 2:Data- 3:Data+ 4:Reserved 5:Reserved 6:Data- 7:5V 8:GND
AC Variable Frequency Drives Type Variflex Terminal symbol TM1 Function description L1(L) Main power input, single phase: L1(L) / L3(N) three phase (200V): L1(L) / L2 / L3(N) three phase (400V): L1 / L2 / L3 L3 (N) P* Externally connected braking resistorBR* Inverter output, connect to U, V, W terminals of motorT2 Ground terminal NPN/PNP input type selection PNP: 1.Link SC and COM terminal 2.Use +24v terminal for S1~S5 common point NPN: 1.Link SC and +24V terminal 2.Use COM terminal for S1~S5 common point Please ensure correct connection before setting parameter group3 digital inputs. Model: Three Phase (PNP/ NPN) 400V: RVLFC340370FA, RVLFC3405500FA, RVLFD340750FA, RVLFD3401100FA Connection Diagrams cont. Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 7 (MCCB AC source AO 250VAC/1A (30VDC/1A) RB RAS5 ON-OFF Surge Suppressor 10V AVI ACI GND Magnetic Contactor RS485 FWD (Run/Stop) REV (Run/Stop) Speed Control External speed potentiometer = 10 Kohm or PID input Induction Motor COM:NPN MC Thermal relay MC GND 0~10V AO Frequency Indicator 0~10VDC CON2 Thermal relay M 0~20mA P P'2'1 +24V:NPN * RC SC COM:PNP +24V:PNP Power input P BR Inverter output Ground Pin 1 to Pin 8 Multifunction Input Terminals Relay Output Analog Output Analog Input 1:Data+ 2:Data- 3:Data+ 4:Reserved 5:Reserved 6:Data- 7:5V 8:GND * P , BR for three phase 400V models
AC Variable Frequency Drives Type Variflex Terminal Description cont. Terminal symbol TM2 Function description Signal Level RA Relay output terminal, specification: 250VAC/1A (30VDC/1A) 240VAC/1A (30VDC/1A)RB COM S1~S5 (Common) [NPN] +/- 15%, Max output current 30mA+24 S1~S5 (Common) [PNP] S1~S5 Multi-function input terminals (refer to group3) 24 VDC, 4.5 mA, optical coupling isolation (Max, voltage 30VDC, input impedance 6kΩ) 10V Built in power for an external speed potentiometer 10V, (Max current:20mA) AVI Analog voltage input, Specification: 0/2~10VDC (choose by parameter 04-00) 0~10V (Input impedance 200kΩ) ACI Analog current input, Specification: 0/4~20mA (choose by parameter 04-00) 0~20mA (Input impedance 499Ω) AO Multi-function analog output terminal. Maximum output 10VDC/1mA 0~10V (Max current 2mA) AGND Analog ground terminal Frame A & Frame B 8 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 Single phase (100V & 200V) Three phase (200V) Three phase (400V) Note: the screw on L2 terminal is removed for the single phase input supply models L1(L) L2 L3(N) T1 T2 T3 L1(L) L2 L3(N) T1 T2 T3 L1 L2 L3 P BR T1 T2 T3
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 9 Motor Controllers AC Variable Frequency Drives Type Variflex Terminal Description cont. Terminal symbol TM2 Function description Signal Level +24V Common point of PNP input +/- 15%, Max output current 30mASC NPN/PNP selectable terminal. NPN input: +24V&SC need to be shorted. PNP input: COM&SC need to be shorted. COM Voltage reference point for S1~S5 S1~S5 Multi-function input terminals (refer to group3) 24 VDC, 4.5 mA, optical coupling isolation (Max, voltage 30VDC, input impedance 6kΩ) 10V Built in power for an external speed potentiometer (Max output : 20mA) 10V, (Max current:20mA) AVI / PTC Analog voltage input/motor over temperature protection signal input, Specification: 0/2~10VDC 0~10V (Input impedance 200kΩ) ACI Analog current input, Specification: 0/4~20mA (choose by parameter 04-00) 0~20mA (Input impedance 499Ω) AO Multi-function analog output terminal. Maximum output 10VDC/1mA 0~10V (Max current 2mA) AGND Analog ground terminal Frame C & Frame D NPN: RA RB COM S1 S2 S3 S4 S5 10V AVI ACI AO AGND PNP: RA RB +24V S1 S2 S3 S4 S5 10V AVI ACI AO AGND Terminal symbol TM1 Function description RA Relay output terminal, specification: 250VAC/5A (30VDC/5A) RA: Normally open, RB: Normally close, RC: Common pointRB RC NPN/PNP control terminals: +24V SC COM S1 S2 S3 S4 S5 10V ACI AO AGND RA RB RC TM1 TM2 AVI PTC
10 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 Motor Controllers AC Variable Frequency Drives Type Variflex Dimensions (mm/inches) RVLFB W W1 W2 H H1 H2 H3 D D1 D2 E E1 E2 Weight kg (lbs) 120150FA 118/ 4.65” 108/ 4.25” 108/ 4.25” 144/ 5.67” 131/ 5.16” 121/ 4.76” 114/ 4.49” 150/ 5.91” 144.2/ 5.68” 136.4/ 5.37” 101.32/ 3.99” 96.73/ 3.81” 51.5/ 2.03” 1.45 (3.2)120220FA 320150A 1.35 (2.98)320220A 340075FA 1.45 (3.20)340150FA 340220FA RVLFA W W1 W2 H H1 H2 D D1 D2 E E1 E2 Weight kg (lbs) 110040A 72/ 2.83” 63/ 2.48” 61/ 2.4” 141/ 5.55” 131/ 5.16” 122/ 4.8” 139.2/ 5.48” 136/ 5.35” 128.2/ 5.05” 86.3/ 3.40” 81.1/ 3.19” 55/ 2.17” 0.85 (1.87) 110075A 1.35 (2.98) 120040FA 0.95 (2.09)120075FA 320040A 320075A 2-R2.2 W 2-Ø4.3 D1 D H 55±0.5 81.1±0.5 86.3±0.5 D D H W 2-Ø4.3 2-R2.2 51.5±0.5 96.7±0.5 101.3±0.5 D Frame A Frame B
AC Variable Frequency Drives Type Variflex Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please refer to our sales network. 10/04/2017 11 Dimensions cont. (mm/inches) Frame C RVLFC W W1 H H1 H2 H3 D D1 D2 E E1 E2 Weight kg (lbs) 340370FA 129/ 5.08” 118/ 4.65” 197.5/ 7.78” 177.6/ 6.99” 188/ 7.4” 154.7/ 6.09” 148/ 5.83” 143.7/ 5.66” 136/ 5.35” 102.6/ 4.04” 96/ 3.78” 48.2/ Frame D RVLFD W W1 H H1 H2 H3 D D1 D2 E E1 Weight kg (lbs) 340750FA 187/ 7.36” 176/ 6.93” 273/ 10.75” 249.8/ 9.83” 261/ 10.28” 228.6/ 190/ 7.48” 185.6/ 7.31” 177.9/ 136/ 5.35” 84.7/ 3.33” 6.3 (13.89)3401100FA H W E 2-Q W E H 2-Q