RSS260-D-F0-LSTM12-8 SCHMERSAL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 10
Technical content
RSS260-D-F0-LSTM12-8-0,25M Simple mounting without additional angle Universal coding with RFID technology Frontal and lateral actuation enabled RFID-technology for needs-based protection against tampering 8- pole cable connector M12 Thermoplastic enclosure Data Ordering data Product type description RSS260-D-F0-LSTM12-8-0,25M Article number (order number) 103040374 EAN (European Article Number) 4030661553757 eCl@ss number, version 12.0 27-27-46-01 eCl@ss number, version 11.0 27-27-24-03 eCl@ss number, version 9.0 27-27-24-03 ETIM number, version 7.0 EC001829 ETIM number, version 6.0 EC001829 Approvals - Standards Certificates TÜV cULus FCC IC ANATEL
Coding level according to EN ISO 14119 Low Working principle RFID Frequency band RFID 125 kHz Transmitter output RFID, maximum -6 dBm Housing construction form Block Installation conditions (mechanical) not flush Sensor topology Sensor for series wiring Housing material Plastic, thermoplastic, self-extinguishing Active area Glass-fibre, thermoplastic Reaction time, maximum 100 ms Duration of risk, maximum 200 ms Reaction time, switching off safety outputs via actuator, maximum 100 ms Gross weight 80 g General data - Features Diagnostic output Yes Short circuit detection Yes Cross-circuit detection Yes Series-wiring Yes Safety functions Yes Cascadable Yes Feedback circuit Yes Automatic reset function Yes
Integral system diagnostics, status Yes Number of LEDs 3 Number of semi-conductor outputs with signaling function Number of poles 8 Number of fail-safe digital outputs Safety classification Standards EN ISO 13849-1 EN IEC 61508 Performance Level, up to e Category 4 PFH value 6.80 x 10⁻¹⁰ /h PFD value 1.20 x 10⁻⁴ Safety Integrity Level (SIL), suitable for applications in Mission time 20 Year(s) Mechanical data Actuating panels lateral front side Active area lateral front Mounting A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. Type of the fixing screws 2x M4 Tightening torque of the fixing screws, maximum 0.8 Nm Mechanical data - Switching distances
Typical switching distance, frontal 12 mm Typical switching distance, lateral 9 mm Assured switching distance "ON", frontal 10 mm Assured switching distance "OFF", frontal 18 mm Assured switching distance "ON", lateral 6 mm Assured switching distance "OFF", lateral 15 mm Note (Sao) The specifications of the safety switching distance Sao refer to a temperature range of mm. Note (switching distance) All switching distances in accordance EN IEC 60947-5-3 Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range. Hysteresis (Switching distance), maximum 2 mm Repeat accuracy R 0.5 mm Note (Repeat accuracy R) Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm Mechanical data - Connection technique Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current Note (series-wiring) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD Termination Connector M12, 8-pole, A-coded Mechanical data - Dimensions Length of sensor 29.5 mm Width of sensor 39.2 mm
Ambient temperature -28 ... +65 °C Storage and transport temperature -28 ... +85 °C Relative humidity, maximum 93 % Note (Relative humidity) non-condensing non-icing Resistance to vibrations 10 … 55 Hz, amplitude 1 mm Restistance to shock 30 g / 11 ms Permissible installation altitude above sea level, maximum 2,000 m Ambient conditions - Insulation values Rated insulation voltage Ui 32 VDC Rated impulse withstand voltage Uimp 0.8 kV Overvoltage category III Degree of pollution 3 Electrical data Operating voltage 24 VDC -15 % / +10 % (stabilised PELV power supply) Operating current, minimum 0.5 mA No-load supply current I0, typical 35 mA Rated operating voltage 24 VDC Operating current 600 mA Required rated short-circuit current 100 A
Time to readiness, maximum 2,000 ms Switching frequency, maximum 1 Hz Utilisation category DC-12 24 VDC / 0.05 A Electrical fuse rating, maximum 2 A Electrical data - Safety digital inputs Designation, Safety inputs X1 and X2 Current consumption of the safety inputs 5 mA Test pulse duration, maximum 1 ms Test pulse interval, minimum 100 ms Classification ZVEI CB24I, Sink Classification ZVEI CB24I, Source Electrical data - Safety digital outputs Designation, Safety outputs Y1 and Y2 Rated operating current (safety outputs) 250 mA Output current, (fail-safe output), maximum 0.25 A Design of control elements short-circuit proof, p-type Voltage drop Ud, maximum 1 V Leakage current Ir, maximum 0.5 mA Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12 0.25 A
Voltage, Utilisation category DC-13 Current, Utilisation category DC-13 0.25 A Test pulse interval, typical 1000 ms Test pulse duration, maximum 1 ms Classification ZVEI CB24I, Source Classification ZVEI CB24I, Sink Electrical data - Diagnostic outputs Designation, Diagnostic outputs OUT Operating current 50 mA Voltage drop Ud, maximum 2 V Voltage, Utilisation category DC-12 Current, Utilisation category DC-12 0.05 A Voltage, Utilisation category DC-13 Current, Utilisation category DC-13 0.05 A Electrical data - Electromagnetic compatibility (EMC) Interfering radiation IEC 61000-6-4 Status indication Note (LED switching conditions display) LED yellow: Operating condition LED green: Supply voltage LED red: Fault Pin assignment
PIN 1 A1 Supply voltage UB PIN 2 X1 Safety input 1 PIN 3 A2 GND PIN 4 Y1 Safety output 1 PIN 5 OUT Diagnostic output PIN 6 X2 Safety input 2 PIN 7 Y2 Safety output 2 PIN 8 without function Scope of delivery Scope of delivery Actuator must be ordered separately. Accessory Recommendation (actuator) RST16-1 RST-U-2 RST260-1 Ordering code Product type description: (1) without Standard coding I1 Individual coding I2 Individual coding, multiple teaching (2) D With diagnostic output SD With serial diagnostic function 1) (3) without Standard version without feedback circuit monitoring EDM (External Device Monitoring)
F0 EDM with automatic reset 1) F1 EDM with manual reset 1) (4) without Without EMERGENCY STOP Q Acknowledge input error with EMERGENCY STOP 1) (5) without Connecting cable (lenght in m) ST Connector plug M8, 8-pole LSTM12-8-0,25M Cable 0.25 m long with connector M12, 8-pole LSTM8-8-0,1M Cable 0.1 m long with connector M8, 8-pole LSTM12-5-0.25M Cable 0.25 m long with connector M12, 5-pole (*) 1) only for versions -ST, -LSTM12-8-0.25M and -LSTM8-8- 0.1M Pictures Product picture (catalogue individual photo) ID: krss2f13 | 42.7 kB | .png | 74.083 x 141.817 mm - 210 x 402 px - 72 dpi | 638.8 kB | .jpg | 352.778 x 676.275 mm - 1000 x 1917 px - 72 dpi | 22.4 kB | .jpg | 64.558 x 123.472 mm - 183 x 350 px - 72 dpi Dimensional drawing basic component ID: krss2g02 | 147.2 kB | .ai | 297 x 210.002 mm - 841 x 595 px - 72 dpi | 4.8 kB | .png | 74.083 x 39.864 mm - 210 x 113 px - 72 dpi | 121.3 kB | .jpg | 352.778 x 189.089 mm - 1000 x 536 px - 72 dpi
ID: km12-k8b | 5.3 kB | .png | 73.731 x 87.489 mm - 209 x 248 px - 72 dpi | 138.6 kB | .jpg | 352.425 x 417.689 mm - 999 x 1184 px - 72 dpi Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220 The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible. Generated on: 23/09/2025, 6:16 am