21.04.2011 14:21:41h Print Create PDF Create EXCEL file Hide system components Datasheet AZM 161SK-12/12RK-024 Solenoid interlock AZM 161 (Minor differences between the printed image and the original product may exist!) thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x mm x mm Contacts Long life Large wiring compartment Manual release cable entries M x 1.5 Ordering details Product type

description

B 10d Opener (NC) 2.000.000 Mission time Years notice Global Properties Product name AZM 161 Standards EN 60947-5-1, BG-GS-ET-19 Compliance with the Directives (Y/N) Yes Number of actuating directions piece

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing Material of the contacts Silver Housing coating None Weight 500 g Mechanical data Actuating play in direction of actuation 5.5 mm Design of electrical connection Screw connection Cable section Min. Cable section x 0,75 mm² Max. Cable section x 1.5 mm² Mechanical life 1.000.000 operations Emergency unlocking device (Y/N) No Manual release (Y/N) Yes Emergency release (Y/N) No Latching force N Positive break force N positive break travel mm Clamping force F max 2000 N Max. Actuating speed m/s Actuating frequency max. 1000 h notice All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature Min. environmental temperature 25°C Max. environmental temperature 60°C Protection class IP67 to IEC/EN 60529 Electrical data Design of control element Normally open contact (NO), Opener (NC) Switching principle Creep circuit element Number of auxiliary contacts piece Number of safety contacts piece Power to unlock Yes Power to lock No Rated control voltage U s VAC/DC Power consumption max. W Rated impulse withstand voltage U imp kV Rated insulation voltage U i 250 V Thermal test current I the A Utilisation category AC-15: 230 V DC-13: V 2,5 A Max. fuse rating A gG D-fuse To DIN EN 60269-1 ATEX Explosion protection categories for gases None

Applications

guard, removable guard, hinged safety guard Dimensions Dimensions of the sensor Width of sensor 130 mm Height of sensor mm Length of sensor mm notice Manual release For maintenance, installation, etc. For manual release using triangular key, available as accessory Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Switch travel diagram

VÖ adjustable range of NC contact N after travel Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZM 161SK-12/12RK-024 G ... G Protected against incorrect polarity and voltage spikes. limited terminating space 0,75 mm² Diagram guard open +24 VDC VDC unlocked Ordering code AZM 161 (1) (2)(3) K (4) (5) (6)(7) (1) SK Screw connection CC Cage clamps ST male connector M12, and 4-poles (Only for U s VAC/DC) (2) Normally open contact (NO) Opener (NC) Normally open contact (NO) Opener (NC) (Plug-in connection) Normally open contact (NO) Opener (NC) (Plug-in connection) (3) without Latching force N R Latching force N (4) without Power to unlock A Power to lock (5)

T Emergency exit lateral TD Emergency exit cover-side TU Emergency exit rear N Emergency release (6) 024 U s VAC/DC U s VAC (7) G with LED (Only for U s VAC/DC) Documents Operating instructions and Declaration of conformity (jp) MB, 24.11.2010 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/JP/mrl_azm161_jp.pdf Operating instructions and Declaration of conformity (fr) 752 kB, 16.12.2009 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/FR/mrl_azm161_fr.pdf Operating instructions and Declaration of conformity (es) 711 kB, 16.12.2009 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/ES/mrl_azm161_es.pdf Operating instructions and Declaration of conformity (en) 751 kB, 16.12.2009 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/EN/mrl_azm161_en.pdf Operating instructions and Declaration of conformity (nl) 659 kB, 16.12.2009 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/NL/mrl_azm161_nl.pdf Operating instructions and Declaration of conformity (de) 421 kB, 17.02.2011 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/DE/mrl_azm161_de.pdf Operating instructions and Declaration of conformity (it) 706 kB, 16.12.2009 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/bedien/AZM_161_12_12/IT/mrl_azm161_it.pdf BG-test certificate (de) 219 kB, 09.02.2010 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/baumuste/z_m16p01.pdf BG-test certificate (en) 219 kB, 09.02.2010 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/baumuste/z_m16p02.pdf CCC certification (en) 747 kB, 12.12.2006 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/zertifikat/q_371p02.pdf CCC certification (cn) 725 kB, 12.12.2006 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/zertifikat/q_371p03.pdf notice (de, en) kB, 27.09.2007 http://127.0.0.1/Bilddata/Azm/Pdf/Azm161/sonder/s_161p01.pdf Images

(basic component) Dimensional drawing (basic component) Operating principle System components Actuator 1145117 AZM 161-B1 1144416 AZM 161-B1E