Features

  • 4:1 wide input voltage range
  • SIP8 package
  • Continuous short circuit protection
  • No minimum load requir ed
  • 3kVDC/1min basic isolation UL62368-1 certified C22.2 No. 62368-1-19 certified IEC/EN62368-1 certified CB Report E224736 RECOMCONVERTERS COM PLIANT PRODUCTS REACH compliant RECOMCONVERTERS COM PLIANT PRODUCTS RoHS compliant 10 from 10 RSOK-Z

1 Watt

3kVDC IsolationOutput Voltage RSOK-24 05 SZ/H3 Notes: Note1: Efficiency is tested at minimum input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load Selection Guide Part Number Input Voltage Range [VDC] Output Voltage [VDC] Output Current [mA] Efficiency typ. (1) [%] max. Capacitive Load (2) [µF] RSOK-2405SZ/H3 9-36 5 200 75 1500 BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitors Input Voltage Range nom. VIN= 24VDC 9VDC 36VDC Under Voltage Lockout (UVLO) DC-DC ON 8.1VDC 8.7VDC DC-DC OFF 6VDC 6.66VDC Input Current 160mA Quiescent Current 3mA 10mA Minimum Load 0% ON/OFF CTRL DC-DC ON Open or VCTRL>1.5VDC DC-DC OFF Short to -VIN or <1.5VDC Input Current of CTRL Pin DC-DC ON 1mA Standby Current DC-DC OFF 3mA 6mA Internal Operating Frequency 100kHz 800kHz Output Ripple and Noise (3) 20MHz BW 80mVp-p continued on next page Notes: Note3: Measurements are made with a 0.1µF MLCC across output (low ESR) Specifications (measured @ tamb= 25°C, nom. VIN, full load and after warm-up unless otherwise stated) preliminary

www.recom-power.com REV.: 0/2023 ECO-2 RSOK-Z SeriesDC/DC Converter Specifications (measured @ tamb= 25°C, nom. VIN, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Type Value Short Circuit Protection (SCP) continuous, auto recovery Short Circuit Input Current nom. VIN= 24VDC 120mA max. Isolation Voltage (5) 1 minute I/P to O/P 3kVDC 1.5kVAC/50Hz Isolation Resistance I/P to O/P , VISO= 500VDC 1GΩ min. Isolation Capacitance I/P to O/P , 100kHz/0.1V 50pF max. Insulation Grade according to 62368-1 basic Efficiency vs. Load Power Dissipation vs. Load 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 9Vin 12Vin 24Vin 36Vin 0.5 0.3 0.2 0.1 0.35 0.4 0.45 0.25 0.15 0.05 Power Dissipation [W] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 9Vin 12Vin 25Vin 36Vin REGULATIONS Parameter Condition Value Output Accuracy ±2.0% typ. Line Regulation low line to high line, full load ±0.5% max. Load Regulation (4) 10% to 100% load 1.0% max. 2.5 1.5 0.5 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Deviation vs Load (@nom Vin) Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note6: Refer to local safety regulations if input over -current protection is also required. Recommended fuse: slow blow type Notes: Note4: Operation below 10% load will not harm the converter, but specifications may not be met preliminary

www.recom-power.com REV.: 0/2023 ECO-3 Specifications (measured @ tamb= 25°C, nom. VIN, full load and after warm-up unless otherwise stated) RSOK-Z SeriesDC/DC Converter ENVIRONMENTAL Parameter Condition Value Operating Temperature Range with derating refer to „Derating Graph“ -40°C to +105°C Maximum Case Temperature +115°C Temperature Coefficient ±0.02%/K Thermal Impedance natural convection 0.1m/s 49.17K/W Operating Altitude 5000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 MTBF according to MIL-HDBK-217F, G.B. tAMB= +25°C 2725 x 103 hours tAMB= +85°C 867 x 103 hours -40 -20 0 20 40 70 60-30 -10 10 30 50 80 90 110 100 100 Output Load [%] Ambient Temperature [°C] 12Vin 24Vin 36Vin Derating Graph (@ Chamber and natural convection 0.1m/s) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/Video, information and communication technology equipment - Part1: Safety requirements 3rd Edition E491408-A6025-UL UL62368-1, 3nd Edition, 2019 CAN/CSA-C22.2 No. 62368-1-19 3rd Edition Audio/Video, information and communication technology equipment - Part1: Safety requirements 3rd Edition (CB Scheme) 085-220180801-000 IEC62368-1:2018 3rd Edition EN IEC 62368-1:2020+A11:2020 RoHS2 RoHS 2011/65/EU + AM2015/863 EMC Compliance Condition Standard / Criterion Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements with external filter EN55032, Class B -Vout +Vout -Vin +Vin C1 C2 +Vout+Vin -Vout-Vin CMC1 Component List Class B C1/C2 CMC1 C3/C4 L1 10µF 51µF 3kV 22µH, RLS-226 EMC Filtering Suggestions according to EN55032 preliminary

www.recom-power.com REV.: 0/2023 ECO-4 Specifications (measured @ tamb= 25°C, nom. VIN, full load and after warm-up unless otherwise stated) RSOK-Z SeriesDC/DC Converter DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case black plastic, (UL94 V-0) potting PU, (UL94 V-0) PCB FR4, (UL94 V-0) Dimension (LxWxH) 21.8 x 9.2 x 11.1mm Weight 4.7g typ. 2.54 2.54 2.54 Ø1.0 1 2 3 5 6 7 8 1 2 3 5 6 7 8 7X 2.54 □0.64±0.05 21.8 embossed logo 9.2 9.8 min. 22.4 min. 2.01 0.5 11.14.1±1.0 3.2 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 11.5 x 19.0mm Packaging Quantity tube 22pcs Storage Temperature Range -50°C to +125°C Storage Humidity non-condensing 95% RH max. Dimension Drawing (mm) Recommended Footprint Details Pinning Information Pin # Single 1 -Vin 2 +Vin

3 CTRL

NC= no connection The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. Tolerance: xx.x = ±0.5mm xx.xx = ±0.25mm preliminary