DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

Part Input Output Output Efficiency Max. Cap. Number Voltage Voltage Current (typ.) Load (VDC) (VDC) (mA) (%) REC10-xx3.3S/H*/M 9-18, 18-36, 36-75 3.3 2000 83-84 2200µF REC10-xx05S/H*/M 9-18, 18-36, 36-75 5 2000 86-87 2200µF REC10-xx12S/H*/M 9-18, 18-36, 36-75 12 833 85-86 2200µF REC10-xx15S/H*/M 9-18, 18-36, 36-75 15 667 85-86 2200µF REC10-xx05D/H*/M 9-18, 18-36, 36-75 ±5 ±1000 82-83 ±1000µF REC10-xx12D/H*/M 9-18, 18-36, 36-75 ±12 ±416 85-86 ±1000µF REC10-xx15D/H*/M 9-18, 18-36, 36-75 ±15 ±333 85-86 ±1000µF REC10-xx3.3SZ/H*/M 9-36, 18-75 3.3 2000 82 2200µF REC10-xx05SZ/H*/M 9-36, 18-75 5 2000 86 2200µF REC10-xx12SZ/H*/M 9-36, 18-75 12 833 85 2200µF REC10-xx15SZ/H*/M 9-36, 18-75 15 667 86 2200µF REC10-xx05DZ/H*/M 9-36, 18-75 ±5 ±1000 82 ±1000µF REC10-xx12DZ/H*/M 9-36, 18-75 ±12 ±416 85 ±1000µF REC10-xx15DZ/H*/M 9-36, 18-75 ±15 ±333 86 ±1000µF 2:1 xx = 9-18Vin = 12, xx = 18-36Vin = 24, xx = 36-75Vin = 48 * Standard is /H2 for 2kVDC isolation, use /H3 for 3kVDC Isolation

Description

Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) The REC10-xxxxS_D/M -series offer single and dual regulated outputs in a 2”x1” package with 2kVDC or 3kVDC isolation options and are suitable for higher power industrial applications. Re- mote on/off control is standard. The converters can deliver 150% rated power for short periods of time to cope with applications with large capacitive loads or high start up currents. Input Voltage Range 2:1 or 4:1 Input Filter PI Network Line Voltage Regulation ±0.3% max. Load Voltage Regulation Single ±0.5% max. (25% to 100% full load ) Dual ±1.2% max. Cross Regulation (100%: 25% to 100% full load ) ±5% max. Output Ripple and Noise (with 100n output capacitor and 20MHz BW) 100mVp-p max. Start-up time (Nom. Vin at 100% Load) 25ms typ. Operating Frequency (Full Load) 300kHz typ. Efficiency (Nom. Vin at 100% Load) see Selection Guide Minimum Load 0% Input Surge Voltage (100ms max.) 12V Input 36VDC 24V Input 50VDC 48V Input 100VDC continued on next page

10 Watt

2” x 1” Single & Dual Output 4:1 xx = 9-36Vin = 24, xx = 18-75Vin = 48 EN-60950-1 Certified EN-60601-1 Certified UL-60950-1 Certified E-224736 **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. REV: 0/2015 www.recom-power.comE-166

/MT51 /MT49 /MT50 /MT53 /MT52 /MT50/MT48/MT46/MT51/MT50 /MT53/MT48/MT46/MT56 /MT100/MT105/MT97/MT46 /MT48/MT46/MT56 /MT49/MT48/MT46/MT49/MT54 /MT49/MT48/MT46/MT49/MT54 /MT49/MT50/MT46/MT55/MT48 /MT49/MT53/MT46/MT50/MT52 /MT66/MT111/MT116/MT116/MT111/MT109/MT32/MT86/MT105/MT101/MT119 /MT54 /MT50/MT46/MT53/MT48 /MT53/MT46/MT48/MT56 /MT50/MT53/MT46/MT52 /MT53/MT46/MT54 /MT49/MT48/MT46/MT50 /MT50/MT48/MT46/MT51/MT50/MT49/MT53/MT46/MT50 /MT50/MT46/MT53/MT52 /MT53/MT46/MT48/MT56 REC10/M Specifications cont. (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Isolation Voltage H2-Suffix (tested for 1 second) 2000VDC (rated for 1 minute) 1000VAC / 60Hz H3-Suffix (tested for 1 second) 3000VDC (rated for 1 minute) 1500VAC / 60Hz Under Voltage Lockout (2:1) 12V Input DC-DC on 8.3VDC, DC-DC off 7.9VDC 24V Input DC-DC on 17.4VDC, DC-DC off 16.7VDC 48V Input DC-DC on 35.7VDC, DC-DC off 34.3VDC Under Voltage Lockout (4:1) 24V Input DC-DC on 8.3VDC, DC-DC off 7.9VDC 48V Input DC-DC on 17.4VDC, DC-DC off 16.7VDC Isolation Capacitance 1200pF typ. Isolation Resistance 1 G Ω min. Overload Protection 150% typ. Short Circuit Protection Continuous, Auto Restart Operating Temperature Range 4:1 -40°C to +71°C (see Graph) (free air convection) 2:1 -40°C to +81°C (see Graph) Storage Temperature Range -55°C to +105°C Remote On/Off DC/DC ON Open or 3.5V<Vr<12V DC/DC OFF Short or 0V<Vr<1.2V Temperature Coefficient ±0.05% max. Relative Humidity 95% RH Case Material Nickel Plated Metal with Non-Conductive Base Thermal Impedance Natural convection 12°C/W Maximum Case Temperature 100°C Vibration 10-55Hz, 2G, 30mins along X,Y & Z Package Weight 27g Packing Quantity 10 pcs per Tube MTBF (+25°C) using MIL-HDBK 217F >1000 x 10 3hours (+71°C) using MIL-HDBK 217F >250 x 10 3hours Certifications EN General Safety Report: SPCLVD1211033-2 EN60950-1:2006 + A12:2011 UL General Safety Report: E224736 UL 60950-1 1st Ed. C22.2 No. 60950-1-03 EN Medical Safety Report: MDD12060585 + RM1206085 IEC/EN 60601-1 3rd Edition; Medical Report + ISO14971 Risk Assessment REC10-S_D/H*/M Series ECONOLINE DC/DC-Converter Derating-Graph (Ambient T emperature) 2:1 Converters 4:1 Converters Package Style and Pinning (mm) 2” x 1” Package XX.X ± 0.5 mm XX.XX ± 0.35 mm Pin Connections Pin # Single Dual 1 +Vin +Vin 2 –Vin –Vin 3 +Vout +Vout

4 No Pin Com

5 –Vout –Vout

6 CTRL CTRL

Application Notes chapter "MTBF"} Note: Refer to Application Notes for EMC Class B Filter suggestion /MT79/MT117/MT116/MT112/MT117/MT116/MT32/MT80/MT111/MT119/MT101/MT114/MT32/MT40/MT37/MT41 /MT49/MT48/MT48 /MT54/MT48 /MT50/MT48 /MT52/MT48 /MT49/MT48/MT48/MT53/MT48/MT48/MT45/MT52/MT48 /MT49/MT53/MT48 /MT79/MT112/MT101/MT114/MT97/MT116/MT105/MT110/MT103/MT32/MT84/MT101/MT109/MT112/MT101/MT114/MT97/MT116/MT117/MT114/MT101/MT32/MT176/MT67 /MT48 /MT56/MT48 /MT83/MT97/MT102/MT101/MT32/MT79/MT112/MT101/MT114/MT97/MT116/MT105/MT110/MT103/MT32/MT65/MT114/MT101/MT97 /MT56/MT49 /MT79/MT117/MT116/MT112/MT117/MT116/MT32/MT80/MT111/MT119/MT101/MT114/MT32/MT40/MT37/MT41 /MT49/MT48/MT48 /MT54/MT48 /MT50/MT48 /MT52/MT48 /MT57/MT48/MT53/MT48/MT48/MT45/MT52/MT48 /MT55/MT49 /MT49/MT53/MT48 /MT79/MT112/MT101/MT114/MT97/MT116/MT105/MT110/MT103/MT32/MT84/MT101/MT109/MT112/MT101/MT114/MT97/MT116/MT117/MT114/MT101/MT32/MT176/MT67 /MT48 /MT56/MT48 /MT83/MT97/MT102/MT101/MT32/MT79/MT112/MT101/MT114/MT97/MT116/MT105/MT110/MT103/MT32/MT65/MT114/MT101/MT97 /MT52/MT58/MT49 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV: 0/2015 E-167www.recom-power.com