Features
- 3W power in compact SMD package
- Operating temperature from -40°C to +81°C with no derating
- 2kVDC or 3kVDC/1minute isolation voltage
- IEC/EN/UL62368 3rd Edition certified
- Fully protected- OLP , OCP & SCP RSH3 Selection Guide Part Input Output Output Efficiency max. Capacitive Number Voltage Range Voltage Current typ. (1) Load (2) [VDC] [VDC] [mA] [%] [µF] RSH3-1205S (3, 4) 9-18 5 600 79 1680 RSH3-1212S (3, 4) 9-18 12 250 81 820 RSH3-1215S (3, 4) 9-18 15 200 82 680 RSH3-1224S (3, 4) 9-18 24 125 82 470 RSH3-1212D (3, 4) 9-18 ±12 ±125 82 ±470 RSH3-1215D (3, 4) 9-18 ±15 ±100 82 ±330 RSH3-2405S (3, 4) 18-36 5 600 80 1680 RSH3-2412S (3, 4) 18-36 12 250 81 820 RSH3-2415S (3, 4) 18-36 15 200 82 680 RSH3-2424S (3, 4) 18-36 24 125 82 470 RSH3-2412D (3, 4) 18-36 ±12 ±125 83 ±470 RSH3-2415D (3, 4) 18-36 ±15 ±100 83 ±330 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load Model Numbering YEAR warr anty3 Notes: Note3: add suffix “/H2” for 2kVDC isolation add suffix “/H3” for 3kVDC isolation, for more information refer to “Isolation Voltage (7)” Note4: without suffix = standard tube packaging add suffix „-R“ for tape and reel packaging for more details, refer to “PACKAGING INFORMATION” Packaging (4) Isolation (3) Single or Dual nom. Output Power nom. Input Voltage Output Voltage Ordering Examples: RSH3-1205S/H2 9-18Vin 5Vout single output 2kVDC/1sec isolation tube packaging (25pcs) RSH3-2405S/H2-R 18-36Vin 5Vout single output 2kVDC/1sec isolation Tape and Reel (150pcs) RSH3-1212D/H3 9-18Vin ±12Vout dual output 3kVDC/1sec isolation tube packaging (25pcs) RECOMCONVERTERS COM PLIANT PRODUCTS REACH compliant RECOMCONVERTERS COM PLIANT PRODUCTS RoHS compliant 10 from 10 UL62368-1 3rd Edition certified CAN/CSA-C22.2 No. 62368-1 certified IEC/EN62368-1 2nd + 3rd Ed. certified EN55032 compliant EN55035 compliant EN55024 compliant CB Report
www.recom-power.com REV.: 0/2022 ECO-2 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RSH3 Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi type Input Voltage Range nom. Vin= 12VDC 24VDC 9VDC 18VDC 18VDC 36VDC Input Surge Voltage nom. Vin= 12VDC 24VDC 25VDC 50VDC Minimum Load 0% ON/OFF CTRL DC-DC ON DC-DC OFF Open or High impedance 4.5VDC Supply to 68W or IN1418 Internal Operating Frequency 100% load 130kHz Output Ripple and Noise (5) 20MHz BW 30mVp-p 75mVp-p Notes: Note5: Measurements are made with a 0.1µF MLCC across output. (low ESR) RSH3-1205S RSH3-2405D RSH3-2405S Efficiency vs. Load 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%]
www.recom-power.com REV.: 0/2022 ECO-3 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RSH3 Series CTRL Circuit RSH3-12XXS_DRSH3-24xxS_D +Vout+Vin CTRL -Vout-Vin 4.5VDC -Vin +Vin VCTRL -Vout +Vout IN4148 +Vout+Vin CTRL -Vout-Vin 68Ω 4.5VDC -Vin +Vin VCTRL -Vout +Vout REGULATIONS Parameter Condition Value Output Accuracy ±1.0% max. Line Regulation low line to high line, full load ±0.2% max. Load Regulation (6) 0% to 100% load 0.5% max. Cross Regulation Asymmetrical load 25%/100% dual output only ±5.0% max. Notes: Note6: Operation below 20% load will not harm the converter, but specifications may not be met PROTECTIONS Parameter Type Value Short Circuit Protection (SCP) below 100mW continuous, auto recovery Over Load Protection (OLP) 100% load 160% typ. Isolation Voltage (7) I/P to O/P with suffix “H2” tested for 1 minute 2kVDC 0.5kVAC with suffix “H3” tested for 1 minute 3kVDC 1kVAC Isolation Resistance 1GW min. Isolation Capacitance 50pF typ. Notes: Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Condition Value Operating Temperature Range @ natural convection 0.1m/s refer to “Derating Graph” -40°C to +100°C Maximum Case Temperature 105°C Temperature Coefficient ±0.05%/K Operating Altitude 5000m Operating Humidity non-condensing 5% to 95% RH max. Pollution Degree PD2 Vibration according to MIL-STD-202G 10-55Hz, 2G, 30min along x y and z axes MTBF according to MIL-HDBK-217F, G.B. +25°C +81°C 2872 x 10³ hours 836 x 10³ hours continued on next page
www.recom-power.com REV.: 0/2022 ECO-4 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RSH3 Series Derating Graph (@ Chamber and natural convection 0.1m/s) -40 -20 0 20 40 7060-30 -10 10 30 50 80 90 110100 100 Output Load [%] Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) File Number Standard Audio/video, information and communication technology equipment. Safety requirements E224736-A6025-UL UL62368-1:2019 3rd Edition CAN/CSA-C22.2 No. 62368-1:2019 Audio/Video, information and communication technology equipment - Part1: Safety requirements (CB) 2002009-1-CB IEC62368-1:2014 2nd Edition Audio/Video, information and communication technology equipment - Part1: Safety requirements EN62368-1:2014 + A11:2017 Audio/Video, information and communication technology equipment - Part1: Safety requirements (CB) 2002009-3-CB IEC62368-1:2018 3rd Edition Audio/Video, information and communication technology equipment - Part1: Safety requirements EN IEC 62368-1:2020 + A11:2020 RoHS2 RoHS-2011/65/EU + AM-2015/863 EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment – Emission Requirements with external filter refer to “EMC Filtering” EN55032:2015 Electromagnetic compatibility of multimedia equipment – Immunity requirements EN55035:2017 Information technology equipment - Immunity characteristics - Limits and methods of measurement EN55024:2010+A1:2015 ESD Electrostatic discharge immunity test Contact: ±2, 4kV IEC61000-4-2:2008, Criteria A EN61000-4-2:2009, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3, 10V/m: (80-1000MHz); 3V/m: (1800, 2600, 3500, 5000MHz) IEC/EN61000-4-3:2006+A2:2010, Criteria A Fast Transient and Burst Immunity DC Power Port: ±0.5, ±2kV IEC/EN61000-4-4:2012, Criteria A Surge Immunity DC Power Port: ±0.5, ±1kV IEC/EN61000-4-5:2014, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields DC Power Port: 3Vr.m.s. (0.15-10MHz) 3-1Vr.m.s. (10-30MHz) 1Vr.m.s. (30-50MHz) 10Vr.m.s. (0.15-80MHz) IEC61000-4-6:2013, Criteria A EN61000-4-6:2014, Criteria A Power Magnetic Field Immunity 1A/m IEC61000-4-8:2009 EN61000-4-8:2010 Limitations on the amount of electromagnetic interference allowed from digital and electronic devices Class B FCC 47 CFR Part 15 Subpart B continued on next page
www.recom-power.com REV.: 0/2022 ECO-5 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RSH3 Series Suggestions according to EN55032 (9) -Vout +Vout -Vin +Vin +Vout+Vin -Vout-Vin -Vout +Vout Com -Vin +Vin +Vout Com +Vin -Vout-Vin Component List Class A MODEL C1 C2 C3 L1 RSH3-1205S/SMD 10µF N/A N/A 3.9µH choke RLS-397RSH3-2405S/SMD RSH3-2415D/SMD Component List Class B MODEL C1 C2 C3 L1 RSH3-1205S/SMD 10µF 10µF 1nF 3.9µH choke RLS-397RSH3-2405S/SMD RSH3-2415S/SMD Single Dual EMC Filtering Notes: Note9: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM for advice. DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case & base non-conductive black plastic, (UL94 V-0) Dimension (LxWxH) 18.9 x 17.2 x 8.7mm Weight 2.5g typ. Dimension Drawing (mm) Pinning Information Pin # Single Dual 1 -Vin -Vin
2 CTRL CTRL
6 NC COM
7 NC -Vout
NC= no connection Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm 6 71 9 814 6 71 9 814 2.54 1.40 2.50 18.0 15.5 6x2.54=15.24 17.2 6x2.54=15.24 12.818.9 8.7 8.4 1.300.80 embossed logo 0.25 Bottom View Top View Recommended Footprint Details
www.recom-power.com REV.: 0/2022 ECO-6 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RSH3 Series PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube tape and reel (carton) reel (diameter + width) 520.0 x 22.20 x 11.80mm 385.0 x 375.0 70.0mm Ø330.0 x 44.0mm Packaging Quantity tube tape and reel 25pcs 150pcs Tape Width 44mm Storage Temperature Range -55°C to +125°C Storage Humidity non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.