RPM-2.0 RECOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Features
- High power density (L*W*H = 12.19*12.19*3.75)
- Wide operating temperature -40°C to +105°C at full load
- Efficiency up to 98%, no need for heatsinks
- 6-sided shielding
- Thermally and EMI enhanced 25 pad LGA package
- Compact DOSA-compatible footprint
- Low profile Notes: Note1: Max. Cap Load is tested at nominal input and full resistive load Model Numbering Selection Guide Part Input Voltage Output Vout Output Efficiency Max. Capacitive Number Range Voltage Adjust Range Current max. typ. Load (1) [VDC] [VDC] [VDC] [A] [%] [µF] RPM5.0-2.0 3 - 17 5 0.9 - 6.0 2 92 - 98 800 Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range Buck mode 3.3Vout 5Vout 3.4VDC 5.1VDC 12VDC 17VDC 100% duty cycle mode (2) Vout= Vin - Vdrop 3.3Vout 5Vout 3VDC 3.4VDC 5.1VDC Absolute Maximum Input Voltage 20VDC Undervoltage Lockout (UVLO) DC-DC ON DC-DC OFF 2.6VDC 2.8VDC 2.7VDC 2.9VDC 2.8VDC 3.0VDC Input Current nom. Vin= 12VDC 3.3Vout 5Vout 0.6A 0.9A Quiescent Current 30µA Internal Power Dissipation 3.3Vout 5Vout 0.7W 0.8W continued on next page max. Output CurrentOutput Voltage RPM__-2.0 EN55032 compliant
www.recom-power.com REV.: 0/2018 RPM-2 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPM-2.0 Series Parameter Condition Min. Typ. Max. Output Voltage Trimming (3) 0.9VDC 6VDC Minimum Dropout Voltage (Vdrop) (4) Vin min. = Vdrop + Vout 50mV/A Minimum Load 0% Start-up Time without using soft start function/ power up using CTRL function 1.6ms 1.5ms Rise-time 1.4ms ON/OFF CTRL DC-DC ON DC-DC OFF Open or 0.9V<VCTRL<Vin Short or -0.3V<VCTRL<0.45VDC Input Current of CTRL Pin DC-DC OFF 1.2µA Standby Current DC-DC OFF 15µA Internal Operating Frequency 1.25MHz Output Ripple and Noise (5) 20MHz BW, 80Ohm @ 100MHz 60mVp-p Absolute Maximum Capacitive Load below 1 second start up + Css = 3700nF below 1 second start up without softstart mode 42000µF 800µF Notes: Note2: As input approaches output voltage set point, device enters 100% duty cycle mode. In 100% duty cycle mode, Vout equals Vin minus dropout voltage (see Dropout vs. Load graph) Note3: For more detailed information, please refer to trim table or calculation on page RPM-3 Note4: Required dropout voltage per 1A output current to be within accuracy (see Dropout vs. Load graph) Note5: Measurements are made with a 22µF MLCC across output (low ESR) Efficiency vs. Load 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 3Vin 5Vin 12Vin 17Vin 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 4Vin 5Vin 12Vin 17Vin Dropout Voltage vs. Load 0.12 0.08 0.04 0.10 0.06 0.02 Dropout Voltage [VDC] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] RPM3.3-2.0 RPM5.0-2.0
www.recom-power.com REV.: 0/2018 RPM-3 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) OUTPUT VOLTAGE TRIMMING The RPM series offers the feature of trimming the output voltage over a range between 0.9V and 6V by using external trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary. Trim up Trim down Voutnom R1 R2 R3 Vref 3.3VDC 376kW 1kW 471kW 0.81VDC5VDC 344kW 431kW Practical Example RPM3.3-2.0: Calculation: Voutnom = nominal output voltage [VDC] Voutset = trimmed output voltage [VDC] Vref = reference voltage [VDC] Rup = trim up resistor [W] Rdown = trim down resistor [W] R1, R2, R3 = internal resistors [W] Rup = 376k - 1k = 375kW4.3 - 3.3 Rup according to E96 ≈ 374kW Rdown according to E96 ≈ 309kW Rdown = (1.8 - 0.81) x 471k = 311kW3.3 - 1.8 Rdown = (Voutset - Vref) x R3 Voutnom - Voutset Rup = - R2 Voutset - Vnom Rup (E96) ≈ 1M87 931k 619k 464k 374k 309k 267k 221k 169k 137k [W] RPM3.3-2.0 Trim up Trim up Trim down Trim down Rdown (E96) ≈ 3M40 1M47 1M 590k 432k 309k 182k 86k6 39k2 17k4 [W] Rup (E96) ≈ 2M21 1M33 976k 750k 619k 523k 453k 402k 357k 324k [W] RPM5.0-2.0 Rdown (E96) ≈ 3M16 1M37 768k 634k 294k 133k 84k5 44k2 20k5 9k53 [W] RPM-2.0 Series Rup +Vout Trim Rdown GND Trim
www.recom-power.com REV.: 0/2018 RPM-4 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPM-2.0 Series REGULATIONS Parameter Condition Value Output Accuracy ±3.0% max. Line Regulation low line to high line, full load 0.25% typ. / ±3.0% max. Load Regulation 0% to 100% load 0.5% typ. / 3.0% max. Soft-Start Time refer to soft-start capacitor calculation Transient Response 100% - 10% load step recovery time 200mV max. 6ms typ. 25% load step change recovery time 150mV max. 500µs typ. continued on next page Sequencing Multiple Modules The SEQ pin can be used to program the rising edge of the output voltage. An internal current source charges a soft-start capacitor which is connected from the sequencing pin to GND. The following equation is used to calculate the soft-start capacitor: Css = soft-start capacitor Iss = sum of all soft-start currents of all sequenced modules tss = required soft-start time n = number of RPMs Iss [µA] Preset soft-start time [µs] 4.5 5.0 5.5 750 825 920 Note: there is a 3.3nF internal soft-start capacitor, and there are different constant current sources in the modules which leads to different preset soft-start times. REMOTE SENSE GND +Vin +Vin GND GND Trim +Sense +Vout Rup RW1 Rdown GND +Vout RW1 ... wire losses + Rup ... trim up resistor Rdown ... trim down resistor The output voltage can be adjusted via the trim and sense functions. The maximum output voltage from Trim and Sense function combined is 5.5VDC. Derating may be required when using Trim and/or sense functions. Css = tss x Iss - n x 3.3nF1.25V
www.recom-power.com REV.: 0/2018 RPM-5 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPM-2.0 Series Vin SEQ GND1 GND3 GND2 NC Trim PGood Sense Vout Vin Vout Vin Vout CTRL Vin Vout(1) Vout(n) Vout(n+1) RPM(1) RPM(n) RPM(n+1) CTRL SEQ GND1 GND3 GND2 NC Trim PGood Sense CTRL Vin C5 C6 SEQ GND1 GND3 GND2 NC Trim PGood Sense CTRL Vin C8 C9 FB1 FB2 FB3 FB5 FB6 FB4 Vin SEQ GND1 GND3 GND2 NC Trim PGood Sense Vout Vin Vout Vin Vout CTRL C1 C2 CSS CTRL Vin Vin Vin Vout(n+1) Vout(n) Vout(1) SEQ GND1 GND3 GND2 NC Trim PGood Sense CTRL C4 C5 C6 SEQ GND1 GND3 GND2 NC Trim PGood Sense CTRL C7 C8 C9 FB1 FB2 FB3 FB4 FB5 FB6 RPM(n) RPM(n+1) RPM(1) To sequence multiple converters to start at the same time (set output voltage is reached at the same time), the following schematic may be used: To sequence multiple power module start-up times the power good (PGood) pin and the CTRL pin may be used. In below schematic, the RPM(n) starts after RPM(1) reaches its set output voltage and the power good signal is set to high which then enables RPM(n). After RPM(n) reaches its set output voltage, it enables RPM(n+1).
www.recom-power.com REV.: 0/2018 RPM-6 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPM-2.0 Series ENVIRONMENTAL Parameter Condition Value Operating Temperature Range (5) @ natural convection 0.1m/s (refer to derating graph) -40°C to +105°C Maximum Case Temperature measured on tc point (see dimension drawing) +110°C Temperature Coefficient @ +65°C Tamb 0.02%/K Thermal Impedance (5) 0.1m/s, horizontal (Tcase to Tamb) 8K/W Operating Altitude with derating @ natural convection 0.1m/s (refer to altitude vs. load graph) 5000m Operating Humidity non-condensing 5% - 95% RH max. Shock MIL-STD-810G, Method 516.6, Procedure I 40g, 11ms, saw-tooth, 3 shocks ± per axis 3 axis; unit is operating MIL-STD-810G, Method 516.6, Procedure IV drop on 50mm plywood on concrete 26 times from 1 meter Temperature Cycling MIL-STD-883F, Method 1010, Condition A powered -50°C to +85°C, 300 cycles Random Vibration MIL-STD-810G, Method 514.6, Procedure I, Category 24 Category 24 - Figure 514.6E-1 - power spectral density = 0.04g2/Hz at 20Hz –1000Hz; -6dB/octave at 1000Hz – 2000Hz; 60 minutes x 3 axis; unit is operating during tests MTBF according to MIL-HDBK-217F, G.B. @ full load +25°C +85°C 2800 x 103 hours 800 x 103 hours Notes: Note5: tested with a eurocard 160x100mm 70µm copper, 4 layer PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) 50mW constant current mode Short Circuit Input Current without soft-start mode 75mA typ. Over Current Protection (OCP) with soft-start mode 120%, pulse by pulse current limitation Over Temperature Protection (OTP) case temperature (measured on tc point) DC-DC OFF DC-DC ON 110°C, auto restart after cool down 100°C typ. -40 -20 0 20 40 7060-30 -10 10 30 50 80 90 110100 100 Output Load [%] Ambient Temperature [°C] 15Vin 12Vin 9Vin 5Vin 4Vin Derating Graph (5) (@ chamber and natural convection 0.1m/s)
www.recom-power.com REV.: 0/2018 RPM-7 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPM-2.0 Series DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case PCB solder pads metal FR4, (UL94 V-0) copper with electrolytic nickel-gold Dimension (LxWxH) 12.19 x 12.19 x 3.75mm Weight 1.1g typ. continued on next page SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/video, information and communication technology equipment. Safety requirements designed to meet EN62368-1 RoHS 2 RoHS 2011/65/EU EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment - emission requirements with external components (see filter suggestions below) EN55032, Class A and B EMC filtering suggestion according to EN55032 Vin SEQ GND1 GND3 GND2 NC Trim PG Sense Vout CTRL Vin Vout FB1 Component List Class A C1 C2 (6) FB1 10µF 25V X7R 10µF 25V X7R WE ref: 742792510 EMC filtering suggestion according to EN55032 Vin SEQ GND1 GND3 GND2 NC Trim PG Sense Vout CTRL Vin Vout FB1 C2 C3 FB2 Component List Class B C1 C2 (6) FB1 FB2 C3 10µF 25V X7R 10µF 25V X7R WE ref: 742792510 WE ref: 7427932 22µF 10V 7XR Notes: Note6: C2 is only required below 10V input voltage
www.recom-power.com REV.: 0/2018 RPM-8 DC/DC Converter Specifications (measured @ ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPM-2.0 Series Dimension Drawing (mm) A B C D E 2 3 4 51 A B C D E 2 3 4 5 tc 11.70 11.70 12.19 ±0.5 1.025 x R0.3 3.75 1.061.06 Top View 1.52 12.19 ±0.2 2.291.52 Bottom View Recommended Footprint Details Pinning information Pad # Function Description A1, A2 Vin Positive input voltage with respect to GND. Connect to a Vin plane for enhanced thermal performance C1 CTRL Active High: pull to GND to disable the device. Pull high or leave open to enable the device A5, B5 Vout Positive output voltage. Connect to a Vout plane for enhanced thermal performance C5 Sense Connect this pad to the load or directly to Vout. This pad must not be left floating E5 Trim Used to set the output voltage between 0.9V and 6V E2 NC Not connected E1 SEQ Used to sequence multiple converters or to set the startup time. Float if not used D1 PGood Output power good. High = Vout at set level, low = Vout below nominal regulation. Maximum sink current is 2mA. It has a high impedance output (100kΩ connected to Vout). Float if not used A3, A4, B1, B2, B3, B4, C2, C3, C4, D2, D3, D4, D5, E3, E4 GND Negative input voltage. Connect to GND plane(s) for enhanced thermal performance tc = case temperature measuring point Tolerance: xx.xx= 0.25mm PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tape and reel tape and reel (carton) 330.2 x 330.2 x 30.4mm 355.0 x 350.0 x 50.0mm Packaging Quantity tape and reel 500pcs Tape Width 24mm Storage Temperature Range -55°C to +125°C Storage Humidity non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.