RP90Q-RW RECOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 15

Technical content

Features

  • 4:1 Wide Input Range
  • 3kVAC Reinforced Insulation for 110Vin 2.25kVDC Basic Insulation for 24Vin & 48Vin
  • Efficiency up to 90%
  • No Minimum Load Required
  • EN50155 Certified
  • IEC/EN60950-1 Certified RP90Q-RW EN50155 Certified IEC/EN60950-1 Certified Selection Guide Part Number Input Output Output Input(1) Output Efficiency (1) Max. Capacitive Voltage Range Voltage Current Current Power typ. Load [VDC] [VDC] [mA] [mA] [W] [%] [µF] RP90Q-2405SRW(2,3) 9-36 5 18000 4213 90 89 36000 RP90Q-2412SRW(2,3) 9-36 12 7500 4213 90 89 6250 RP90Q-2415SRW(2,3) 9-36 15 6000 4213 90 89 4000 RP90Q-2424SRW(2,3) 9-36 24 3700 4157 89 89 1540 RP90Q-2448SRW(2,3) 9-36 48 1800 4090 86.5 88 380 RP90Q-4805SRW(2,3) 16.5-75 5 18000 2107 90 89 36000 RP90Q-4812SRW(2,3) 16.5-75 12 7500 2107 90 89 6250 RP90Q-4815SRW(2,3) 16.5-75 15 6000 2083 90 90 4000 RP90Q-4824SRW(2,3) 16.5-75 24 3700 2055 89 90 1540 RP90Q-4848SRW(2,3) 16.5-75 48 1800 2000 86.5 90 380 RP90Q-11005SRW(2,3) 40-160 5 17000 868 85 89 34000 RP90Q-11012SRW(2,3) 40-160 12 7000 858 84 89 5830 RP90Q-11015SRW(2,3) 40-160 15 5500 843 82.5 89 3670 RP90Q-11024SRW(2,3) 40-160 24 3500 858 84 89 1460 RP90Q-11048SRW(2,3) 40-160 48 1800 882 86.5 89 380 Ordering Examples RP90Q-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function RP90Q-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function RP90Q-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, with premounted Heat-sink Model Numbering Input Voltage Output Voltage Single Notes: Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) or add suffix “N” instead for negative logic (0=ON, 1=OFF) Note3: add suffix “-HC” for premounted Heat-sink (compatible with all other suffixes) The quarter-brick RP90Q series DC/DC converters are designed for railway rolling stock and high voltage battery applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to 160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal base - plates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink). The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock and vibration environments. The converters are EN50155 and IEC/EN60950 certified. The RP90Q-RW series have a three year warranty. CTRL Logic(2) Package(3) Notes: Note1: Efficiency is tested by nominal Vin, full load and at 25°C.

PB-2 REV.: 2/2016 www.recom-power.com RP90Q-RW Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi-Type Input Voltage Range nom Vin = 24V nom Vin = 48V nom Vin = 110V 9VDC 16.5VDC 40VDC 24VDC 48VDC 110VDC 36VDC 75VDC 160VDC Input Surge Voltage Vin = 24V, 1s max. Vin = 48V, 1s max. Vin = 110V, 1s max. 50VDC 100VDC 185VDC Quiescent Current Vin = 24V Vin = 48V Vin = 110V 25ma 15mA 8mA Start-up time Power up ON/OFF Control 75ms 75ms 100ms 100ms Internal Operating Frequency 270kHz 300kHz 330kHz Minimum Load 0% Ripple and Noise Measured by 20MHz BW with a 22µF/25V X7R MLCC with a 22µF/25V X7R MLCC with a 4.7µF/50V X7R MLCC with a 2.2µF/100V X7R MLCC

5 Vout

12, 15Vout 24Vout 48Vout 75mVp-p 100mVp-p 200mVp-p 300mVp-p Under Voltage Lockout (UVLO) Vin = 24V DC-DC ON DC-DC OFF 7.3VDC 9VDC 8.1VDC Vin = 48V DC-DC ON DC-DC OFF 15.5VDC 18VDC 16.3VDC Vin = 110V DC-DC ON DC-DC OFF 33VDC 43VDC 36VDC ON/OFF Control Positive Logic DC-DC ON DC-DC OFF Open or 3.0V < Vr < 12V Short or 0V < Vr < 1.2V Negative Logic DC-DC ON DC-DC OFF Short or 0V < Vr < 1.2V Open or 3.0V < Vr < 12V Input Current of CTRL pin -0.5mA 1mA Standby Current 3mA Output Trim -20% +10% Remote Sense % of set Vout 10% continued on next page Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted Efficiency vs. Input Voltage 9Vin 24Vin 36Vin Efficiency [%] Output Current [%] 100 100 100% Load 50% Load 25% Load Efficiency [%] Input Voltage [V] 24 30 36 100 27 33 RP90Q-2405SRW Efficiency vs. Output Current

PB-3REV.: 2/2016www.recom-power.com Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted RP90Q-RW Series 9Vin 24Vin 36Vin Power Dissipation [W] Output Current [%] 20 30 40 50 60 70 80 90 100 RP90Q-2405SRW Power Dissipation vs. Output Current Power up Start-up Rise CharacteristicON/OFF Control Start up Rise Characteristic Typical Output Ripple and Noise/full load RP90Q-4805SRW Efficiency vs. Input Voltage 16.5Vin 24Vin 48Vin 75Vin Efficiency [%] Output Current [%] 60 80 100 100 70 90 100% Load 50% Load 25% Load Efficiency [%] Input Voltage [V] 16.5 48 60 7572 100 54 66 Efficiency vs. Output Current

PB-4 REV.: 2/2016 www.recom-power.com Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted RP90Q-RW Series continued on next page 16.5Vin 24Vin 48Vin 75Vin Power Dissipation [W] Output Current [%] 60 70 8020 40 10030 50 90 Efficiency vs. Input Voltage 40Vin 75Vin 110Vin 160Vin Efficiency [%] Output Current [%] 10 20 40 60 80 10030 50 70 90 100 100% Load 50% Load 25% Load Efficiency [%] Input Voltage [V] 40 50 60 70 80 90 100 110 120 130 140 150 160 100 RP90Q-11005SRW Efficiency vs. Output Current RP90Q-4805SRW Power Dissipation vs. Output Current Power up Start-up Rise CharacteristicON/OFF Control Start up Rise Characteristic Typical Output Ripple and Noise/full load

PB-5REV.: 2/2016www.recom-power.com Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted RP90Q-RW Series OUTPUT TRIM 43Vin 110Vin 160Vin Power Dissipation [W] Output Current [%] 40302010 50 60 70 80 90 100 RP90Q-11005SRW Power Dissipation vs. Output Current Power up Start-up Rise CharacteristicON/OFF Control Start up Rise Characteristic Typical Output Ripple and Noise/full load Output Voltage Trimming RP90Q-RW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary; they also can be calculated with below shown equation. TRIM DOWNTRIM UP RU 6 5 RD

PB-6 REV.: 2/2016 www.recom-power.com DC/DC Converter Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series RP90Q-xx05SRW RP90Q-xx12SRW RP90Q-xx15SRW RP90Q-xx24SRW RP90Q-xx48SRW Trim Down all Vout‘s Trim up 1 2 3 4 5 6 7 8 9 10 % R1 = 1580 806 536 402 324 247 237 205 187 169 KOhms Trim up 1 2 3 4 5 6 7 8 9 10 % R1 = 4530 2320 1540 1150 931 787 681 604 536 487 KOhms Trim up 1 2 3 4 5 6 7 8 9 10 % R1 = 5760 2940 1960 1470 1210 1020 866 768 698 619 KOhms Trim up 1 2 3 4 5 6 7 8 9 10 % R1 = 9530 4870 3240 2940 2000 1690 1470 1270 1150 1050 KOhms Trim up 1 2 3 4 5 6 7 8 9 10 % R1 = 19600 9945 6650 5110 4120 3400 3010 2610 2370 2150 KOhms Trim down 1 2 3 4 5 6 7 8 9 10 % R2 = 499 243 162 118 909 75 63.4 53.6 46.4 41.2 KOhms Trim down 11 12 13 14 15 16 17 18 19 20 % Trim Calculation Vout = Output Voltage R1 = q 511*Vout+5.11DVout * Vout) - (511+10.22DVout) rkΩ DVout = Output Voltage Trim in % 1.225*DVout DVout R1 = trim up resistor R2 = trim down resistor R2 = q 511 - 10.22rkΩ DVout Practical Example: Trim Up: Vout = 5V, DVout = 10% (5.5V) 1.225*DVout DVout 1.225*10 10 Trim down: Vout = 5V, DVout = -10% (4.5V) R2 = q 511 - 10.22rkΩ = 511 - 10.22 = 41.2kΩ DVout 10

PB-7REV.: 2/2016www.recom-power.com Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series REGULATIONS Parameter Condition Value Output Accuracy ±1.0% Line Regulation low line to high line at full load ±0.1% Load Regulation 0% to 100% load 5Vout others ±0.2% ±0.1% Transient Response 25% load step change 250µs typ. RW1 ... wire losses + RW2 ... wire losses - R1 ... trim up resistor R2 ... trim down resistor +Vout -Vout (GND) +Sense RW1 RW2 -Sense Trim Load Transient Response to Dynamic Load Change from 100% to 75% to 100% of Full Load at nom.Vin RP90Q-4805SRWRP90Q-2405SRW RP90Q-11005SRW The output voltage can be adjusted by both trim and remote sense. The maximum combined adjustment range ±10%. Derate the maximum out - put power if using the trim or sense function.

PB-8 REV.: 2/2016 www.recom-power.com DC/DC Converter Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) below 100mΩ continuous, automatic recovery Over Voltage Protection (OVP) % of nom. Vout 115%-130%, Hiccup Mode Over Load Protection (OLP) % Iout rated 110%-140%, Hiccup Mode Over Temperature Protection (OTP) +110°C Isolation Voltage 110Vin I/P to O/P I/P or O/P to Baseplate 3kVDC/1minute 1.5kVDC/1minute 24Vin, 48Vin I/P to O/P I/P or O/P to Baseplate 2.25kVDC/1minute 2.25kVDC/1minute Isolation Resistance 500 VDC 1GΩ min. Isolation Capacitance 1500pF max. Isolation Grade 110Vin 24Vin, 48Vin Reinforced Insulation Basic Insulation ENVIRONMENTAL Parameter Condition Value Operating Baseplate Temperature Range -40°C to +100°C Maximum Case Temperature 100°C Temperature Coefficient ±0.02%/°C max. Thermal Impedance vertical direction by natural convection (0.1m/s) without Heat-sink vertical direction by natural convection (0.1m/s) with Heat-sink 9°C/W 7.5°C/W Operating Humidity 5% - 95% RH Pollution Degree PD2 Shock according to EN61373 standard Thermal Shock according to MIL-STD-810F standard Vibration according to EN61373 standard Fire protection on railway vehicles according to EN45545-2, 2013 standard MTBF according to MIL-HDBK-217F standard, 25°C 507.0 x 103 hours continued on next page Notes: Note4: An input fuse is required if the mains supply isn’t over-current protected. Recommended fuse: T35A slow blow. Rthcase-ambient = 9°C/W (vertical) Tcase = Case Temperature R thcase-ambientHC = 7.5°C/W (vertical) Tambient = Environment Temperature Pdissipation = Internal losses R thcase-ambient = Tcase - Tambient P IN = Input Power Pdissipation POUT = Output Power h = Efficiency under given Operating Conditions P dissipation = PIN - POUT = POUTapp - POUTapp R thcase-ambient = Thermal Impedance h Practical Example: Take the RP90Q-2405SRW with 9V input Voltage and 50% load. What is the maximum ambient operating temperature? Use converter vertical in application without airflow. Effmin = 89% @ Vnom P OUT = 90W P OUTapp = 90 x 0.5 = 45W h = 91% (Efficiency vs. Load Graph) P dissipation = 45 - 45 = 4.45W 0.91 without Heat-sink with Heat-sink R th = Tcasemax - Tamb --> 9°C/W = 100-Tamb RthHC = Tcasemax - Tamb --> 7.5°C/W = 100-Tamb Pdissipation 4.45W Pdissipation 4.45W T amb = 60°C T ambHC = 66°C Thermal Calculation

PB-9REV.: 2/2016www.recom-power.com Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series -40 60 80 100 12040200-20 100 Ambient Temperature [°C] Output Power [%] natural convection 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s -40 60 80 100 12040200-20 100 Ambient Temperature [°C] Output Power [%] 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s RP90Q-2405SRW RP90Q-2405SRW-HC Derating Graph(5) (@ Chamber - tested with forced convection) Notes: Note5: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part- number not shown here please contact our technical support service at techsupportAT@recom-power.com -40 60 80 100 12040 200-20 100 Ambient Temperature [°C] Output Power [%] 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s -40 60 80 100 12040200-20 100 Ambient Temperature [°C] Output Power [%] natural convection 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s RP90Q-11005SRW RP90Q-11005SRW-HC -40 60 80 100 12040 200-20 100 Ambient Temperature [°C] Output Power [%] 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s -40 60 80 100 12040200-20 100 Ambient Temperature [°C] Output Power [%] natural convection 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s RP90Q-4805SRW-HCRP90Q-4805SRW

Certificate Type (Safety) Report / File Number Standard IEC/EN Information Technology Equipment - General Requirments for Safety TW1608086-001 IEC60950-1, 2nd Edition, 2005 EN60950-1, 2nd Edition, 2006 Railway Applications - Electrical Equipment used on rolling stock TW1608078-001 EN50155, 2007 EMI Compliance Condition Standard / Criterion Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement with external filter EN55022, Class A and Class B Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement EN55011, Class A and Class B ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity(6) Surge Immunity(6) Immunity to conducted disturbances, induced by radio-frequency fields Power Magnetic Field Immunity Air ±8kV and Contact ±6kV

20 V/m

±2kV EN55024 & EN50155 ±2kV 10 Vr.m.s 100A/m continuous; 1000A/m 1s EN61000-4-2, Criteria A EN61000-4-3, Criteria A EN61000-4-4, Criteria A EN61000-4-5, Criteria A EN61000-4-6, Criteria A EN61000-4-8, Criteria A continued on next page PB-10 REV.: 2/2016 DC/DC Converter Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series www.recom-power.com Notes: Note6: An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5. The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel. Recom suggest: Nippon Chemi-con KY series, 220µF/100V. The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel. Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V Fuse RP90Q-24xxSRW, Class A RP90Q-48xxSRW, Class A RP90Q-110xxSRW, Class A C1 C2 C4C3 +VIN -VIN LOAD C10 Case C5 C6 C7 C8 C11 C12 C13 C14 Fuse +VIN -VIN LOAD Case C8C7 RP90Q-48xxSRW, Class B RP90Q-24xxSRW, Class B RP90Q-110xxSRW, Class B Fuse C2 C3 +VIN -VIN LOADCase L1 L2 Shield Plane C4 C5 C7 C11C10 C13C12 Fuse+VIN -VIN LOADCase L1 L2 Shield Plane C2 C3 C7C6 C5 C9C8 Fuse C2 C3 +VIN -VIN LOADCase Shield Plane Shield Plane Shield Plane C5C4 C6 C8 C12C11 C10 C14C13 MODEL C1 C2, C3, C4 C5 C6, C7, C8 C9 to C14 L1 RP90Q-24xxSRW N/A 6.8µF, 50V 1812 MLCC N/A 6.8µF, 50V

1812 MLCC

1000pF, 3kV

1808 MLCC

0.68µH, 17A SMD Inductor RP90Q-48xxSRW 4.7µF, 100V 4.7µF, 100V 4.7µF, 100V 4.7µF, 100V 1000pF, 3kV 3.3µH, 10A SMD Inductor EMI Filtering according to EN55022/11 Class A and EN50121-1 (24Vin and 48Vin)

PB-11REV.: 2/2016www.recom-power.com Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series continued on next page Conducted Emission EN55022 Class A Conducted Emission EN55022 Class ARP90Q-2405SRW RP90Q-4805SRWFuse RP90Q-24xxSRW, Class A RP90Q-48xxSRW, Class A RP90Q-110xxSRW, Class A C1 C2 C4C3 +VIN -VIN LOAD C10 Case C5 C6 C7 C8 C11 C12 C13 C14 Fuse +VIN -VIN LOAD Case C8C7 RP90Q-48xxSRW, Class B RP90Q-24xxSRW, Class B RP90Q-110xxSRW, Class B Fuse C2 C3 +VIN -VIN LOADCase L1 L2 Shield Plane C4 C5 C7 C11C10 C13C12 Fuse+VIN -VIN LOADCase L1 L2 Shield Plane C2 C3 C7C6 C5 C9C8 Fuse C2 C3 +VIN -VIN LOADCase Shield Plane Shield Plane Shield Plane C5C4 C6 C8 C12C11 C10 C14C13 EMI Filtering according to EN55022/11 Class A and EN50121-1 (110Vin) MODEL C1, C2 C3 to C8 L1 RP90Q-110xxSRW 39µF, 250V Al cap. (lie down) Rubycon BXF 1000pF, 3kV 30.1µH, 5A SMD Inductor

PB-12 REV.: 2/2016 DC/DC Converter Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series www.recom-power.com continued on next page Conducted Emission EN55022 Class ARP90Q-11005SRW EMI Filtering according to EN55022/11 Class B (24Vin) Fuse RP90Q-24xxSRW, Class A RP90Q-48xxSRW, Class A RP90Q-110xxSRW, Class A C1 C2 C4C3 +VIN -VIN LOAD C10 Case C5 C6 C7 C8 C11 C12 C13 C14 Fuse +VIN -VIN LOAD Case C8C7 RP90Q-48xxSRW, Class B RP90Q-24xxSRW, Class B RP90Q-110xxSRW, Class B Fuse C2 C3 +VIN -VIN LOADCase L1 L2 Shield Plane C4 C5 C7 C11C10 C13C12 Fuse+VIN -VIN LOADCase L1 L2 Shield Plane C2 C3 C7C6 C5 C9C8 Fuse C2 C3 +VIN -VIN LOADCase Shield Plane Shield Plane Shield Plane C5C4 C6 C8 C12C11 C10 C14C13 MODEL C1 to C8 C9, C10, C13, C14 C11, C12 L1 RP90Q-24xxSRW 10µF, 50V 1000pF, 3kV 2200pF, 3kV 285µH CMC Conducted Emission EN55022 Class B RP90Q-2405SRW

PB-13REV.: 2/2016www.recom-power.com Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series continued on next page Fuse RP90Q-24xxSRW, Class A RP90Q-48xxSRW, Class A RP90Q-110xxSRW, Class A C1 C2 C4C3 +VIN -VIN LOAD C10 Case C5 C6 C7 C8 C11 C12 C13 C14 Fuse +VIN -VIN LOAD Case C8C7 RP90Q-48xxSRW, Class B RP90Q-24xxSRW, Class B RP90Q-110xxSRW, Class B Fuse C2 C3 +VIN -VIN LOADCase L1 L2 Shield Plane C4 C5 C7 C11C10 C13C12 Fuse+VIN -VIN LOADCase L1 L2 Shield Plane C2 C3 C7C6 C5 C9C8 Fuse C2 C3 +VIN -VIN LOADCase Shield Plane Shield Plane Shield Plane C5C4 C6 C8 C12C11 C10 C14C13 Conducted Emission EN55022 Class BRP90Q-4805SRW EMI Filtering according to EN55022/11 Class B (48Vin) MODEL C1 to C7 C8 to C13 L1 L2 RP90Q-48xxSRW 4.7µF, 100V 1000pF, 3kV 620µH CMC 285µH CMC Fuse RP90Q-24xxSRW, Class A RP90Q-48xxSRW, Class A RP90Q-110xxSRW, Class A C1 C2 C4C3 +VIN -VIN LOAD C10 Case C5 C6 C7 C8 C11 C12 C13 C14 Fuse +VIN -VIN LOAD Case C8C7 RP90Q-48xxSRW, Class B RP90Q-24xxSRW, Class B RP90Q-110xxSRW, Class B Fuse C2 C3 +VIN -VIN LOADCase L1 L2 Shield Plane C4 C5 C7 C11C10 C13C12 Fuse+VIN -VIN LOADCase L1 L2 Shield Plane C2 C3 C7C6 C5 C9C8 Fuse C2 C3 +VIN -VIN LOADCase Shield Plane Shield Plane Shield Plane C5C4 C6 C8 C12C11 C10 C14C13 EMI Filtering according to EN55022/11 Class B (110Vin) MODEL C1, C2, C3 C4 to C9 L1 L2 RP90Q-110xxSRW 39µF, 250V Al cap. (lie down) Rubycon BXF 1000pF, 3kV 735µH CMC 30.1µH, 5A SMD Inductor

PB-14 REV.: 2/2016 DC/DC Converter Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series www.recom-power.com RP90Q-110xxSRW Conducted Emission EN55022 Class B DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Value Material Case Plastic Baseplate Aluminium Potting Silicone (UL94 V-0) Packaging Dimension (LxWxH) without Heat-sink with Heat-sink 57.9 x 36.6 x 12.7mm 57.9 x 36.6 x 18.8mm Packaging Weight without Heat-sink with Heat-sink 64g 88g continued on next page Dimension Drawing (mm) 15.24 7.62 10.8 FC 47.24 3.81 3.5 11.43 FC 26.5 FC 50.80 5.10 57.9 36.8 2xM3 Bottom View 12.7 Ø2.0Ø1.0 Pin Connections Pin # Single 1 +Vin

2 CTRL

6 Trim

FC= Fixing Centers for Heat-sink Pin Pitch Tolerance ±0.25mm Pin Dimension Tolerance ±0.1mm XX.X ± 0.5mm XX.XX ± 0.25mm

PB-15REV.: 2/2016www.recom-power.com Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) RP90Q-RW Series PACKAGING INFORMATION Parameter Type Value Packaging Dimension Tray without Heat-sink with Heat-sink 157.0 x 88.0 x 12.8mm 157.0 x 88.0 x 24.8mm Packaging Quantity 2pcs Storage Temperature Range -55°C to +125°C Storage Humidity 5% - 95% RH The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. 36.8 FC 47.24 FC 26.5 57.9 4xM3 5.10 18.8 Ø2.0 6.1 Ø1.0 Heat-sink Notes: Note7: Max. tightening torque for Heat-sink: 0.34Nm