RP20-FR RECOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Features
- Wide 4:1 Input Voltage Range
- 1.6kVDC Isolation
- Efficiency up to 89%
- Six-Sided Continuous Shield
- EN50155, UL60950 Certified PD-1REV.: 0/2016www.recom-power.com DC/DC Converter
3 YEAR
Description
The RP20-FR series wide range input DC/DC converters are certified to UL60950-1 and cUL 60950-1. This makes them ideal for all telecom and industrial applications where approved safety standards are required. The 110VDC input versions have been especially designed for railway applications.
20 Watt
2“ x 1“ Single & Dual Output RP20-FR Selection Guide Part Number Input Output Output Input(1) Efficiency (1) Max. Capacitive Voltage Range Voltage Current Current typ. Load [VDC] [VDC] [mA] [mA] [%] [µF] RP20-243.3SFR(2,3) 9-36 3.3 4500 728 85 7000 RP20-2405SFR(2,3) 9-36 5 4000 947 88 5000 RP20-2412SFR(2,3) 9-36 12 1670 938 89 850 RP20-2415SFR(2,3) 9-36 15 1330 945 88 700 RP20-483.3SFR(2,3) 18-75 3.3 4500 364 85 7000 RP20-4805SFR(2,3) 18-75 5 4000 473 88 5000 RP20-4812SFR(2,3) 18-75 12 1670 469 89 850 RP20-4815SFR(2,3) 18-75 15 1330 467 89 700 RP20-1103.3SFR(2,3) 43-160 3.3 4500 159 85 7000 RP20-11005SFR(2,3) 43-160 5 4000 209 87 5000 RP20-11012SFR(2,3) 43-160 12 1670 207 88 850 RP20-11015SFR(2,3) 43-160 15 1330 206 88 700 RP20-2412DFR(2,3) 9-36 ±12 ±833 947 88 ±500 RP20-2415DFR(2,3) 9-36 ±15 ±667 937 89 ±350 RP20-4812DFR(2,3) 18-75 ±12 ±833 473 88 ±500 RP20-4815FDFR(2,3) 18-75 ±15 ±667 468 89 ±350 RP20-11012DFR(2,3) 43-160 ±12 ±833 207 88 ±500 RP20-11015DFR(2,3) 43-160 ±15 ±667 204 89 ±350 Model Numbering Ordering Examples RP20-2405SFR/P = 24V Input, 5V Output, Positive Logic CTRL pin and Trim pin fitted RP20-4812DFR/N-HC = 48V Input, ±12V Output, Negative Logic CTRL pin, with fitted Heat-sink RP20-2405SFR/XC = 24V Input, 5V Output, no CTRL pin and Trim pin fitted Input Voltage Output Voltage Single or Dual Notes: Note1: at nominal input voltage and full load EN50155 Certified UL60950 Certified CSA C22.2 No.601.1 Certified E196683 Notes: Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) and trim pin or add suffix “N” instead for negative logic (0=ON, 1=OFF) and trim pin or add suffix “XC” instead for no CTRL pin (0=ON, 1=OFF) and trim pin Note3: add suffix “-HC” for premounted Heat-sink with clamps Package(3) CTRL Logic(2)
Parameter Condition Min. Typ. Max. Input Voltage Range nom. Vin = 24V nom. Vin = 48V nom. Vin = 110V 9VDC 18VDC 43VDc 24VDC 48VDC 110VDC 36VDC 75VDC 160VDC Under Voltage Lockout (UVLO) Vin = 24V DC-DC ON DC-DC OFF 8VDC 9VDC Vin = 48V DC-DC ON DC-DC OFF 16VDC 18VDC Vin = 110V DC-DC ON DC-DC OFF 40VDC 43VDC Input Filter 24Vin, 48Vin Common Mode Choke 110Vin Pi-Type Input Reflected Ripple Current nominal Vin and full load 30mAp-p Input Surge Voltage Vin =24V, 100 ms max. Vin = 48V, 100 ms max. Vin = 110V, 100 ms max. 50VDC 100VDC 170VDC Start-up time Power up Remote ON/OFF 30ms 30ms Operating Frequency Range 297kHz 330kHz 363kHz Ripple and Noise measured by 20Mhz bandwidth with a 1µF/50V X7R MLCC 3.3Vout, 5Vout 12Vout, 15Vout 75mVp-p 100mVp-p Remote ON/OFF(4) Positive Logic DC-DC ON DC-DC OFF Open or 3.0V < Vr < 15V Short or 0V < Vr < 1.2V Negative Logic DC-DC ON DC-DC OFF Short or 0V < Vr < 1.2V Open or 3.0V < Vr < 15V Input current of Remote pin (CTRL) DC-DC OFF 2.5mA DC-DC ON -0.5mA 1.0mA continued on next page PD-2 REV.: 0/2016 www.recom-power.com DC/DC Converter RP20-FR Series Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted Notes: Note4: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin. If no suffix is specified, the control pin will be omitted. Efficiency vs. Output Current Efficiency vs. Input Voltage full load 9Vin 24Vin 36Vin Efficiency [%] Output Current [%] 20 40 60 80 10030 50 70 90 Efficiency [%] Input Voltage [VDC] 15 18 24 30 3612 21 27 33 RP20-2405SFR
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted REGULATIONS Parameter Condition Value Output Voltage Accurary full load and nominal Vin ±1% Voltage Adjustability Single ±10% Line Voltage Regulation low line to high line at full load Single Dual ±0.2% ±0.5% Load Voltage Regulation 0% to 100% load Single Dual ±0.2% ±1.0% 10% load to 90% load Single Dual ±0.1% ±0.8% Cross Regulation asymmetrical 25%<>100% load ±5% Transient Response recovery time 25% load step change 250µs typ. continued on next page RP20-FR Series PD-3REV.: 0/2016www.recom-power.com Efficiency vs. Output Current Efficiency vs. Output Current Efficiency vs. Input Voltage full load Efficiency vs. Input Voltage full load 18Vin 48Vin 75Vin Efficiency [%] Output Current [%] 20 40 60 80 10030 50 70 90 43Vin 110Vin 160Vin Efficiency [%] Output Current [%] 20 40 60 80 10030 50 70 90 Efficiency [%] Input Voltage [VDC] 30 36 48 60 66 7524 42 54 72 Efficiency [%] Input Voltage [VDC] 62 72 96 125 16014352 84 110 136 RP20-4805SFR RP20-1105SFR
PD-4 REV.: 0/2016 www.recom-power.com DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP20-FR Series External Output Trimming TRIM UP TRIM DOWN Output Voltage Trimming Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resis tor required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below. Trim up 1 2 3 4 5 6 7 8 9 10 % Trim down 1 2 3 4 5 6 7 8 9 10 % RP20-xx3.3SFR Trim up 1 2 3 4 5 6 7 8 9 10 % Trim down 1 2 3 4 5 6 7 8 9 10 % Trim up 1 2 3 4 5 6 7 8 9 10 % Trim down 1 2 3 4 5 6 7 8 9 10 % Trim up 1 2 3 4 5 6 7 8 9 10 % Trim down 1 2 3 4 5 6 7 8 9 10 % RP20-xx05SFR RP20-xx12SFR RP20-xx15SFR RU RD
Operating Temperature Range without derating with derating -40°C to +79°C -40°C to +101°C Maximum Case Temperature +105°C Temperature Coefficient ±0.02%/°C max. Thermal Impedance Natural convection (20LFM) without Heat-sink Natual convection (20LFM) with Heat-sink 12°C/W 10°C/W Operating Humidity 5% - 95% RH Shock EN61373, MIL-STD-810F Thermal Shock MIL-STD-810F Vibration EN61373, MIL-STD-810F MTBF MIL-HDBK-217F 1523 x 103 hours DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP20-FR Series PD-5REV.: 0/2016www.recom-power.com PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) continuous, automatic recovery Over Voltage Protection (OVP) Zener Diode Clamp 3.3Vout 5Vout 12Vout 15Vout 3.7VDC - 5.4VDC 5.6VDC - 7.0VDC 13.5VDC - 19.6VDC 16.8VDC - 20.5VDC Over Load Protection (OLP) % Iout rated 150% typ. Isolation Voltage I/P to O/P I/P to O/P to case 1.6kVDC/1minute 1.6kVDC/1minute Isolation Resistance 500 VDC 1GΩ min. Isolation Capacitance 3000pF max. Notes: Note5: This power module is not internally fused. An input line fuse must always be used. Notes: Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part- number not shown here please contact our technical support service at techsupportAT@recom-power.com -40 60 80 100101 12040200-20 100 Ambient Temperature [°C] Output Power [%] -40 60 8085 100 101 12040200-20 100 Ambient Temperature [°C] Output Power [%] Derating Graph(6) RP20-2415SFR RP20-2415SFR-HC
Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety E196683 UL60950-1, 2nd Edition CSA C22.2 No. 601.1 Railway Applications - Electrical Equipment used on rolling stock 15A100704E-C EN50155 EMI Compliance Condition Standard / Criterion Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement(7) EN55011, Class A and B Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement(7) EN55022, Class A and B ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity(8) Surge Immunity(8) Immunity to conducted disturbances, induced by radio-frequency fields Power Magnetic Field Immunity Air ±8kV and Contact ±6kV
10 V/m
±2kV ±2kV 10 Vr.m.s 100A/m continuous; 1000A/m 1s EN61000-4-2, Criteria A EN61000-4-3, Criteria A EN61000-4-4, Criteria A EN61000-4-5, Criteria A EN61000-4-6, Criteria A EN61000-4-8, Criteria A continued on next page PD-6 REV.: 0/2016 www.recom-power.com DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP20-FR Series Notes: Note7: The 24VDC & 48VDC input standard modules meet EN55022 & EN55011 Class B without external components, 110VDC input meet EN55022 Class A without external components and meet Class B with external components. Note8: An external input filter capacitor is required if the module has to meet EN61000-4-4, -5. The filter Recom suggests: 24VDC and 48VDC input.Nippon chemi-con KY series, 220µF/100V. 110VDC input: Rubycon BXF series, 100µF/250V Fuse Fuse C5C1 C2 C4C3 +VIN -VIN LOAD 100µF 250VDC +VIN -VIN LOAD Fuse 100µF 250VDC +VIN -VIN LOADLOADLOADLOAD Fuse C5C1 C2 C4C3 +VIN -VIN Fuse Fuse C5C1 C2 C4C3 +VIN -VIN LOAD 100µF 250VDC +VIN -VIN LOAD Fuse 100µF 250VDC +VIN -VIN LOADLOADLOADLOAD Fuse C5C1 C2 C4C3 +VIN -VIN EMC Filtering Class B EMC Railway Class A
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP20-FR Series PD-7REV.: 0/2016www.recom-power.com Notes: Note9: Use fuse or over-current protection. Fuse Fuse C5C1 C2 C4C3 +VIN -VIN LOAD 100µF 250VDC +VIN -VIN LOAD Fuse 100µF 250VDC +VIN -VIN LOADLOADLOADLOAD Fuse C5C1 C2 C4C3 +VIN -VIN MODEL C1 C2/C3/C4 C7 L1 RP20-110xxSFR 39µF/250V Al Cap. (lie down) Rubycon BX 0.47µF/250V
1812 MLCC
1808 MLCC
CMC: 470µH ref.: WE-SL5 744272471 DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Value Material Case Base Potting Nickel coated copper FR4 PCB Silicone (UL94V-0) Packaging Dimension (LxWxH) without Heat-sink with Heat-sink 50.8 x 25.4 x 10.2mm 56.8 x 25.4 x 16.8mm Packaging Weight without Heat-sink with Heat-sink 30g 41g Pin Connections Pin # Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout
4 Trim Com
6 CTRL CTRL
Pin Pitch Tolerance ±0.25mm Pin dimension tolerance ±0.1mm XX.X ± 0.5mm XX.XX ± 0.25mm Dimension Drawing (mm) Bottom View 10.2 50.8 20.3015.20 25.4 5.6 5.10 2.5 15.20 20.32 5.08 10.1610.16 12.70 ø1.0
PD-8 REV.: 0/2016 www.recom-power.com DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP20-FR Series The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) Tube Tray 255 x 55 x 22mm 302.5 x 222 x 28mm Packaging Quantity without Heat-sink with Heat-sink Tube Tray 9pcs. 20pcs. Storage Temperature Range -55°C to +125°C Storage Humidity 5% - 95% RH Dimension Drawing (mm) with Heat-sink 10.2 16.8 20.3015.20 56.8 25.4 5.6 5.10 2.5 ø1.0 24.20 50.00 5.85 1.40 1.30 1.60 1.30 Top View