RP10-A RECOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Features

  • 2:1 Wide Input Voltage Range
  • 1.6kVDC Isolation
  • UL Certified
  • Efficiency up to 91%
  • Six-Sided Continuous Shield
  • No Minimum Load Required PD-1REV.: 0/2016www.recom-power.com DC/DC Converter

3 YEAR

Description

The RP10-A series are wide input voltage range 1”x1” power DC/DC converters. Despite their small size, the RP10-A converters are fully specified devices with built-in Class B EMC filters, no minimum load, 1.6kVDC isolation, under-voltage lockout and low ripple/noise figures. The outputs are fully pro - tected against short circuits, overcurrent and overvoltage and can be trimmed over a +/-10% range. The RP10-A series will find many uses in applications where board space is at a premium as no exter- nal components are required. E196683 RP10-A Selection Guide Part Number Input Output Output Input(1) Efficiency (1) Max. Capacitive Voltage Range Voltage Current Current typ. Load [VDC] [VDC] [mA] [mA] [%] [µF] RP10-123.3SA(2,3) 9-18 3.3 3000 994 83 3500 RP10-1205SA(2,3) 9-18 5 2000 969 86 2500 RP10-1212SA(2,3) 9-18 12 830 933 89 430 RP10-1215SA(2,3) 9-18 15 670 931 90 350 RP10-1224SA(2,3) 9-18 24 416 914 91 125 RP10-243.3SA(2,3) 18-36 3.3 3000 485 85 3500 RP10-2405SA(2,3) 18-36 5 2000 484 86 2500 RP10-2412SA(2,3) 18-36 12 830 456 91 430 RP10-2415SA(2,3) 18-36 15 670 465 90 350 RP10-2424SA(2,3) 18-36 24 416 457 91 125 RP10-483.3SA(2,3) 36-75 3.3 3000 243 85 3500 RP10-4805SA(2,3) 36-75 5 2000 239 87 2500 RP10-4812SA(2,3) 36-75 12 830 230 90 430 RP10-4815SA(2,3) 36-75 15 670 233 90 350 RP10-4824SA(2,3) 36-75 24 416 229 91 125 RP10-1205DA(2,3) 9-18 ±5 ±1000 969 86 ±1440 RP10-1212DA(2,3) 9-18 ±12 ±416 935 89 ±250 RP10-1215DA(2,3) 9-18 ±15 ±333 925 90 ±180 RP10-2405DA(2,3) 18-36 ±5 ±1000 484 86 ±1440 RP10-2412DA(2,3) 18-36 ±12 ±416 462 90 ±250 RP10-2415DA(2,3) 18-36 ±15 ±333 463 90 ±180 RP10-4805DA(2,3) 36-75 ±5 ±1000 239 87 ±1440 RP10-4812DA(2,3) 36-75 ±12 ±416 229 91 ±250 RP10-4815DA(2,3) 36-75 ±15 ±333 231 90 ±180 UL60950-1 Certified Ordering Examples RP10-2405SA/P = 24V Input, 5V Output, Positive Logic CTRL pin and Trim pin fitted RP10-4805DA/XC-HC = 48V Input, ±5V Output, without CTRL pin, with fitted Heat-sink RP10-2405SA/N = 24V Input, 5V Output, Negative Logic CTRL pin and Trim pin fitted Model Numbering Input Voltage Output Voltage Single or Dual Notes: Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) and trim pin add suffix “N” instead for negative logic (0=ON, 1=OFF) and trim pin or add suffix “XC” instead for no CTRL pin Note3: add suffix “-HC” for premounted Heat-sink with clamps Notes: Note1: at nominal input voltage and full load. Package(3) CTRL Logic(2)

PD-2 REV.: 0/2016 www.recom-power.com DC/DC Converter RP10-A Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range nom. Vin = 12V nom. Vin = 24V nom. Vin = 48V 9VDC 18VDC 36VDC 12VDC 24VDC 48VDC 18VDC 36VDC 75VDC Under Voltage Lockout (UVLO) Vin = 12V DC-DC ON DC-DC OFF 8VDC 9VDC Vin = 24V DC-DC ON DC-DC OFF 16VDC 18VDC Vin = 48V DC-DC ON DC-DC OFF 33VDC 36VDC Input Filter Pi-Type Input Reflected Ripple Current nominal Vin and full load 30mAp-p Input Surge Voltage Vin = 12V, 1s max. Vin = 24V, 1s max. Vin = 48V, 1s max. 25VDC 50VDC 100VDC Start-up time Power up Remote ON/OFF 30ms 30ms Operating Frequency Range 297kHz 330kHz 363kHz Minimum Load of full load 0% Optional Power output voltage trimmed up 10% output voltage trimmed up 20% 11W 12W Ripple and Noise measured by 20MHz bandwidth with a 10µF/25V X7R 1206 MLCC 3.3Vout, 5Vout 12Vout, 15Vout 40mVp-p 60mVp-p measured by 20MHz bandwidth with a 1µF/50V X7R 1206 MLCC 24Vout 60mVp-p Remote ON/OFF Positive Logic DC-DC ON DC-DC OFF Open or 3.0 < Vr < 15VDC Short or 0 < Vr < 1.2VDC Negative Logic DC-DC ON DC-DC OFF Short or 0 < Vr < 1.2VDC Open or 3.0 < Vr < 15VDC Input current of Remote pin (CTRL) DC-DC OFF 2.5mA DC-DC ON -0.5 mA 1.0mA Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted Efficiency vs. Output Current Efficiency vs. Input Voltage 18Vin 24Vin 30Vin 36Vin Efficiency [%] Output Current [%] 20 40 60 80 10030 50 70 90 Efficiency [%] Input Voltage [V] 22 24 28 32 3620 26 30 34 RP10-2405SA

Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP10-A Series PD-3REV.: 0/2016www.recom-power.com REGULATION Parameter Condition Value Output Voltage Accuracy ±1% Voltage adjustability(4) Single 3.3Vout, 12Vout Others ±10% -10% to +20% Line Voltage Regulation low line to high line Single Dual ±0.2% ±0.5% Load Voltage Regulation 0% to 100% load Single Dual ±0.2% ±1.0% 10% to 90% load Single Dual ±0.1% ±0.8% Cross Regulation asymmetrical 25%<>100% load ±5% Transient Response recovery time 25% load step change 250µs typ. continued on next page Notes: Note4: Trimming allows the user to increase or decrease the output voltage set point of the module. This is accomplished by connecting an external resistor between the Trim pin and either +Vout pin or -Vout pin. External Output Trimming Output Voltage Trimming Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resis tor required or use a variable resistor to set the output voltage. Trim up 1 2 3 4 5 6 7 8 9 10 % Trim down 1 2 3 4 5 6 7 8 9 10 % RP10-xx3.3SA TRIM UP TRIM DOWN RU RD Trim up 1 2 3 4 5 6 7 8 9 10 % Trim up 11 12 13 14 15 16 17 18 19 20 % Trim down 1 2 3 4 5 6 7 8 9 10 % RP10-xx05SA

PD-4 REV.: 0/2016 www.recom-power.com DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP10-A Series PROTECTION Parameter Condition Value Short Circuit Protection (SCP) continuous, automatic recovery Over Voltage Protection (OVP) Zener Diode Clamp 3.3Vout 5Vout 12Vout 15Vout 24Vout 3.7 - 5.4V 6.3 - 7.4V 13.5 - 19.6V 18.3 - 22.0V 29.1 - 32.5V Over Load Protection (OLP) Hiccup mode 150% typ. Isolation Voltage I/P to O/P I/P (O/P) to case 1.6kVDC/1 minute 1.0kVDC/1 minute Isolation Resistance tested with 500VDC 1GΩ min. Isolation Capacitance 1500pF max. Notes: Note5: This power module is not internally fused. An input line fuse must always be used. Trim up 1 2 3 4 5 6 7 8 9 10 % Trim down 1 2 3 4 5 6 7 8 9 10 % RP10-xx12SA RP10-xx15SA Trim up 1 2 3 4 5 6 7 8 9 10 % Trim up 11 12 13 14 15 16 17 18 19 20 % Trim down 1 2 3 4 5 6 7 8 9 10 % Trim up 1 2 3 4 5 6 7 8 9 10 % Trim up 11 12 13 14 15 16 17 18 19 20 % Trim down 1 2 3 4 5 6 7 8 9 10 % RP10-xx24SA

Operating Temperature Range without derating with derating -40°C to +78°C -40°C to +100°C Maximum Case Temperature +105°C Temperature Coefficient ±0.02%/°C max. Thermal Impedance Natural convection (20LFM) without Heat-sink Natural convection (20LFM) with Heat-sink 18.2°C/W 15.8°C/W Operating Humidity 5% - 95% RH Thermal Shock MIL-STD-810F Vibration MIL-STD-810F MTBF MIL-HDBK-217F 3308 x 103 hours DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP10-A Series PD-5REV.: 0/2016www.recom-power.com Derating Graph(6) Notes: Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part- number not shown here please contact our technical support service at techsupportAT@recom-power.com -40 60 8078 10040200-20 100 Ambient Temperature [°C] Output Power [%] -40 60 80 10040200-20 100 Ambient Temperature [°C] Output Power [%] RP10-2405SA RP10-2405SA-HC SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard UL General Safety E196683 UL60950-1, 1st Ed.: 2003 C22.2 No. 60950, 1st Ed.: 2003 EMC Compliance Condition Standard / Criterion EMI Standard(7) with external filter EN55022, Class A or B ESD Radiated Immunity Fast Transient(8) Surge(8) Conducted Immunity Power frequency magnetic field Air ±8kV and Contact ± 6kV

10 V/m

±2kV ±1kV 3 Vr.m.s 100A/m continuous, 1000A/m 1 second EN61000-4-2, Criteria A EN61000-4-3, Criteria A EN61000-4-4, Criteria A EN61000-4-5, Criteria A EN61000-4-6, Criteria A EN61000-4-8, Criteria A continued on next page Notes: Note7: The standard modules meet EMI Class A without external components and Class B with external components; see filter suggestions below. RP10-4805SA meets EMI Class B without external components. Note8: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Recom suggests: Nippon chemi-con KY series, 220µF/100V.

DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Value Material Case Base Potting Copper Alloy C2680 FR4 PCB Epoxy (UL94-V0) Package Dimensions (LxWxH) without Heat-sink with Heat-sink 25.4 x 25.4 x 9.9mm 31.4 x 25.4 x 16.5mm Package Weight without Heat-sink with Heat-sink 16.5g 22.94g continued on next page PD-6 REV.: 0/2016 www.recom-power.com DC/DC Converter Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP10-A Series Dimension Drawing (mm) Bottom View 25.4 2.54 7.62 9.95.6 20.32 10.2 5.08 12.70 25.4 Ø 1.0 Pin Connections Pin # Single Dual 1 +Vin +Vin 2 -Vin -Vin

3 CTRL(2) CTRL(2)

5 Trim Com

Pin Pitch Tolerance ±0.25mm Pin dimension tolerance ±0.1mm XX.X ± 0.5mm XX.XX ± 0.25mm EMI Filtering Class B Input Input DC DC Fuse Fuse +VIN +VOUT -VOUT -VIN LOADLOADLOAD DC DC +VIN +VOUT GND -VOUT -VIN Input Input DC DC Fuse Fuse +VIN +VOUT -VOUT -VIN LOADLOADLOAD DC DC +VIN +VOUT GND -VOUT -VIN MODEL C1 RP10-12xxS_DA 10µF/25V

1812 MLCC

RP10-24xxS_DA 6.8µF/50V RP10-48xxS_DA 4.7µF/100V

Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted RP10-A Series PD-7REV.: 0/2016www.recom-power.com Dimension Drawing (mm) with Heat-sink 31.4 5.6 16.5 9.9 20.32 25.4 Ø 1.0 2.54 24.20 24.20 Top View Heat-sink 5.85 PACKAGING INFORMATION Parameter Type Value Packaging Dimensions (LxWxH) Tube Tray 257 x 28.5 x 21mm 230 x 180 x 28mm Packaging Quantity without Heat-sink with Heat-sink Tube Tray 8pcs. 20pcs. Storage Temperature Range -55°C to +125°C Storage Humidity 5% - 95% RH Tube Dimension Drawing (mm) The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. 26.5±0.5 14.5±0.5 19±0.5 11.4±0.5 R1.5