< Microwave motion sensor with intelligent functions < Reliable detection of people and vehicles < Direction detection < Cross traffic suppression < "Slow motion" for extremely slow motions < Simplest adjustement of the sensing range Premium radar motion sensor offering additional functions, dynamic version offering direction detection, 2 m x 4.5 m detection range, max. installation height: 4 m, black housing, relay contact output, cable connection Function An effective opening of doors or industrial doors can be achieved very flexibly with the RMS microwave motion sensor series. The RC versions offer remote-controlled adjustment of parameters. Ultramodern microcontroller evaluation technology guarantees a variety of field sizes and universal use even in difficult conditions. The 24 GHz microwave technology enables a diverse range of operating modes such as direction detection. The cross-traffic suppression function only opens the door if people approach the door from the front, but not if they are walking past it. Thanks to the slow-motion mode, even extremely slow movements are detected, which increases convenience in senior citizens' residences, for example. Release date: 2020-10--

08 Date of

Release date: 2020-10-08 Date of issue: 2020-10-08 Filename: 184329_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

82.5 36.5 ø 3.7 ø 3.7 19.5 57 123 Technical Data General specifications Sensing range broad: 2000x 4500 mm (DxW) at 2200 mm mounting height and 30° tilt angle narrow: 4500x 2000 mm (DxW) at 2200 mm mounting height and 30° tilt angle Function principle Microwave module Detection speed min. 0.1 m/s Setting angle Horizontal: -30° ... +30° in 5° increments Vertical: 0° ... 90° in 10° increments Operating mode Radar motion sensor Transmitter radiated power (EIRP) < 20 dBm Functional safety related parameters MTTFd 640 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Indicators/operating means Function indicator LED red/green Control elements DIP-switch for selection of operating modes : Direction detection , Cross traffic suppression , Slow-motion , Switching type Control elements sensitivity adjustment Control elements Adjustment for off delay Electrical specifications No-load supply current I0 ≤ 50 mA at 24 V DC Radar sensor RMS-D Release date: 2020-10-08 Date of issue: 2020-10-08 Filename: 184329_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Power consumption P0 ≤ 1.2 W at 24 V DC ≤ 1.7 W at 36 V DC Output Switching type NO/NC Signal output Relay, 1 NO contact/NC contact Switching voltage max. 48 V AC / 48 V DC Switching current max. 0.5 A AC / 1 A DC Switching power max. 24 W / 60 VA De-energized delay toff 0.2 ... 5 s adjustable (1 sec factory setting) Approvals and certificates CE conformity 2014/53/EU This device can be used in all countries within the European Union. In other countries, all applicable national regulations must be observed. FCC approval No - Use in North America is not permitted. Ambient conditions Relative humidity max. 90 % non-condensing Mechanical specifications Mounting height max. 4000 mm Degree of protection IP54 Connection Male connector 4-pin , 5 m connecting cable included with delivery Material Housing ABS, anthracite Mass 120 g Dimensions 123 mm x 65 mm x 57 mm Suitable series Series RMS Connection Assignment Option: BK/2 WH/1 RD/3 GN/4 C NO ~/0 V ~/+UB Assembly

1 IR transmitter (RC version only)

2 Antenna

3 IR receiver (RC version only)

4 DIP switches

5 Potentiometer

6 LED (red/green)

7 T erminal

Release date: 2020-10-08 Date of issue: 2020-10-08 Filename: 184329_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

RMS Weather Cap All-weather hood for RMS series microwave sensors, for ceiling and wall installation RMS/RaDec Ceiling Kit wh Ceiling mount kit for radar sensors in the RMS and RaDec Series Radar sensor RMS-D Release date: 2020-10-08 Date of issue: 2020-10-08 Filename: 184329_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Release date: 2020-10-08 Date of issue: 2020-10-08 Filename: 184329_eng.pdf RMS-D Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Radar sensor Change the size of the detection area using the potentiometer. You can change its position in 10° increments from 0° to 40°. The default setting is 15°. The following features can be adjusted using the DIP switch: 1. Detection without direction detection Forward/backward 2. Detection with direction detection Forward (toward the sensor) Backward (away from the sensor) 3. Cross-traffic suppression Without suppression: door opens even in the event of cross-traffic With suppression: door remains closed in the event of cross-traffic 4. Slow motion mode Slow motion mode door open If the door is open, the smallest movements are detected. The door closes if no movement is detected within the set monitoring time (1/3/5 seconds). If the time is set to 1 second or 3 seconds, the sensitivity gradually reduces over the set time (door closes). If the time is set to 5 seconds, movements are continuously detected at maximum sensitivity. Slow motion mode door closed Size of detection area Position of the detection area Settings

Release date: 2020-10-08 Date of issue: 2020-10-08 Filename: 184329_eng.pdf RMS-D Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Radar sensor If an object has approached so slowly that it has not been detected by normal motion detection, the door opens anyway when the object approaches the door. 5. Relay contacts Other suitable accessories can be found at www.pepperl-fuchs.com Microwave sensors are microwave scanners that use the principle of the Doppler radar. The most important requirement for microwave detection is that the object to be detected is moving. The microwave sensors emit microwaves of a defined frequency in order to detect people and large objects moving at speeds b e t w e e n 1 0 0m m / s e c a n d 5m / s e c . The microwaves emitted by the emitter are reflected back from the ground or other surfaces to the receiver. If there is no motion in the monitored zone, the emitted and reflected frequencies are identical. Nothing is detected. If people, animals or objects are moving in the monitored zone, the reflected frequency changes and therefore triggers a detection. Based on the latest 24 GHz technology with integrated microprocessor control, these sensors provide a high degree of reliability even in difficult operating conditions. The 24 GHz frequency, known as the ‘K-band,’ is reserved by CETECOM for this application area worldwide. The RMS-D series of sensors are equipped with intelligent functions to enable them to be used in a wide variety of applications. The cross-traffic suppression function is particularly effective in narrow shopping streets and shopping arcades. The system can be configured so that the door opens only when a person approaches it, while ignoring passing pedestrians. With direction detection, the opening impulse can be triggered based on the direction of motion. Depending on the setting, only movements towards or away from the sensor are detected. The "slow-motion mode" provides a tangible increase in comfort for senior citizens homes or hospitals. This mode allows detection of extremely slow movements in the direct vicinity of the closing area and can be selectively configured for an open door or a closed door. In the first case, the door is held open when there are slow movements. In the second case, the closed door opens even if a person is approaching so slowly that he would not be recognized by normal motion detection devices.

  • Opening impulse sensor for automatic and industrial doors
  • Monitoring approach areas to automatic doors and elevators
  • Motion sensor for people and objects
  • Impulse sensor for escalators
  • Opening impulse sensor for entry doors Active Relay contact is closed when movement is detected Passive Relay contact is opened when movement is detected Function indicator Green LED Red LED LED flashes green LED flashes red LED flashes green/red Device ready for operation Detection Command received Fault Initialization (for approximately 10 seconds after activation) Accessories Function Principle Application