Feb.1999 MITSUBISHI DIODE MODULES RM60SZ-6S,-6R MEDIUM POWER GENERAL USE NON-INSULATED TYPE OUTLINE DRAWING & CIRCUIT DIAGRAM Dimensions in mm APPLICATION Welders RM60SZ-6S,6R
- VRRM Repetitive peak reverse voltage
- TRIPLE ARMS
- Non-Insulated Type 93.5 2–φ6.5 12.5 17.5 20 20 3–M5 6.5 (S) SR1 A (R) LABEL SR2 SR3 A2 A3 SR1 SR2 SR3 K1 K2 K3 K
Feb.1999 ABSOLUTE MAXIMUM RATINGS Unit V V V MITSUBISHI DIODE MODULES RM60SZ-6S,-6R MEDIUM POWER GENERAL USE INSULATED TYPE 300 400 240 Symbol V RRM VRSM VR (DC) Parameter Repetitive peak reverse voltage Non-repetitive peak reverse voltage Reverse DC voltage Voltage class Unit A A A A Hz N·m kg·cm N·m kg·cm g Conditions Three-phase, half wave average current, TC=110°C One half cycle at 60Hz, peak value Value for one cycle of surge current Main terminal screw M5 Mounting screw M6 Typical value Ratings 1200 6.0 × 10 1000 –40~150 –40~125 1.47~1.96 15~20 1.96~2.94 20~30 130 Symbol IF (RMS) IF (AV) IFSM I2t f Tj Tstg Parameter RMS forward current Average forward current Surge (non-repetitive) forward current I2t for fusing Maximum operating frequency Junction temperature Storage temperature Mounting torque Weight Unit mA V °C/W °C/W Limits Symbol IRRM VFM Rth (j-c) Rth (c-f) Parameter Repetitive reverse current Forward voltage Thermal resistance Contact thermal resistance Min. Typ. Max. 1.5 1.2 0.3 0.25
ELECTRICAL CHARACTERISTICS
Tj=150°C, VRRM applied Tj=25°C, IFM=200A, instantaneous meas. Junction to case (per 1/3 module) Case to fin, conductive grease applied (per 1/3 module)
Feb.1999 MITSUBISHI DIODE MODULES RM60SZ-6S,-6R MEDIUM POWER GENERAL USE NON-INSULATED TYPE PERFORMANCE CURVES MAXIMUM FORWARD CHARACTERISTIC ALLOWABLE SURGE (NON-REPETITIVE) FORWARD CURRENT FORWARD CURRENT (A) CONDUCTION TIME (CYCLES AT 60Hz) FORWARD VOLTAGE DROP (V) MAXIMUM TRANSIENT THERMAL IMPEDANCE (JUNCTION TO CASE) MAXIMUM POWER DISSIPATION TIME (s) AVERAGE FORWARD CURRENT (A) ALLOWABLE CASE TEMPERATURE VS. AVERAGE FORWARD CURRENT CASE TEMPERATURE (°C) AVERAGE FORWARD CURRENT (A) TRANSIENT THERMAL IMPEDANCE (°C/W) SURGE (NON-REPETITIVE) FORWARD CURRENT (A) POWER DISSIPATION (W) –310 –210 –110 010 110 010 310 210 110 010 7050302075320 200 1600 101 100 400 600 800 1000 1200 1400 753275327532 0.40 7532 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.8 1.0 1.6 1.41.2 Tj=25°C 0 06 0 8 0 20 160 60 06 0 8 0 20 100 120 140 RESISTIVE, INDUCTIVE LOAD RESISTIVE, INDUCTIVE LOAD