RM200DA-20F MITSUBISHI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Feb.1999 MITSUBISHI FAST RECOVERY DIODE MODULES RM200DA-20F,-24F HIGH SPEED SWITCHING USE INSULATED TYPE OUTLINE DRAWING & CIRCUIT DIAGRAM Dimensions in mm APPLICATION Free wheel use, Welders RM200DA-20F,-24F

  • VRRM Repetitive peak reverse voltage
  • Insulated Type
  • UL Recognized Yellow Card No. E80276 (N) File No. E80271 (93) 25 25 21.5 K2A1 A2 K1 (48) 62±0.5 30MAX. 17 8 17 8 17 3 K1A2 SR2 A1 SR1 K2 LABEL 4–φ6.5 3–M6

Feb.1999 ABSOLUTE MAXIMUM RATINGS (Tj=25°C) Unit V V V MITSUBISHI FAST RECOVERY DIODE MODULES RM200DA-20F,-24F HIGH SPEED SWITCHING USE INSULATED TYPE 1000 1100 800 Symbol V RRM VDRM VR (DC) Parameter Repetitive peak reverse voltage Non-repetitive peak reverse voltage Reverse DC voltage Unit A A A V N·m kg·cm N·m kg·cm g Conditions Resistive load, TC=75°C One half cycle at 60Hz, peak value Value for one cycle surge current Charged part to case Main terminal screw M6 Mounting screw M6 Typical value Ratings 200 4000 1.65 × 10 –40~+150 –40~+125 2500 1.96~2.94 20~30 1.96~2.94 20~30 460 Symbol IDC IFSM I2t Tj Tstg Viso Parameter DC current Surge (non-repetitive) forward current I2t for fusing Junction temperature Storage temperature Isolation voltage Mounting torque Weight Voltage class Unit mA V µs µC °C/W °C/W Limits Symbol IRRM VFM trr Qrr Rth (j-c) Rth (c-f) Parameter Repetitive reverse current Forward voltage Reverse recovery time Reverse recovery charge Thermal resistance Contact thermal resistance Test conditions T j=150°C, VRRM applied Tj=25°C, IFM=200A, Instantaneous meas. IFM=200A, Tj=150°C, di/dt=–400A/µs, VR=600V Junction to case Case to fin, conductive grease applied Min. Typ. Max. 1.5 0.8 130 0.25 0.4

ELECTRICAL CHARACTERISTICS

Feb.1999 MITSUBISHI FAST RECOVERY DIODE MODULES RM200DA-20F,-24F HIGH SPEED SWITCHING USE INSULATED TYPE PERFORMANCE CURVES MAXIMUM FORWARD CHARACTERISTIC MAXIMUM TRANSIENT THERMAL IMPEDANCE (JUNCTION TO CASE) FORWARD CURRENT (A) TIME (s)FORWARD VOLTAGE (V) RATED SURGE (NON-REPETITIVE) FORWARD CURRENT REVERSE RECOVERY CHARACTERISTICS VS. FORWARD CURRENT (TYPICAL) CONDUCTION TIME (CYCLES AT 60Hz) FORWARD CURRENT (A) REVERSE RECOVERY CHARACTERISTICS VS. –di/dt (TYPICAL) Irr (A), Qrr (µC) –di/dt (A/ µs) SURGE (NON-REPETITIVE) FORWARD CURRENT (A) Zth (j-c) (°C/W)Irr (A), Qrr (µC) trr (µs) trr (µs) –110 –310 –210 010 010 110 010 110 210 310 010 310 210 110 210 110 010 –110 010 310 210 110 010 110 210 310 210 110 010 –110 310 210 110 010 2.21.81.00.6 1.4 Tj=25°C 754320 800 1600 2400 3200 4000 7050403020 3600 2800 2000 1200 400 1 10 100 7532757532 0.32 0.24 0.20 0.04 234 5 7 0.28 0.16 0.12 0.08 753275327532 Irr trr Qrr Tj=150°C Tj=25°C VR=600V di/dt=–400A/µs 753275327532 Irr trr Qrr Tj=25°C Tj=150°C VR=600V IF=200A